FGHGF A92Z ArtNet 1024

Contents

ArtNet 1024 2 Port Bidirectional ArtNet Converter

Model: A92Z ArtNet 1024 | Brand: FGHGF

Introduction

The FGHGF A92Z ArtNet 1024 is a high-performance, bi-directional converter designed to bridge Ethernet-based ArtNet signals with DMX512 lighting control systems. Equipped with high-speed ARM processors, this device ensures real-time, stable, and reliable conversion, making it an essential tool for professional lighting setups. It features an RJ45 network interface and two standard DMX512 output interfaces, supporting 1024 DMX channels (two universes of 512 channels).

Front view of the A92Z ArtNet 1024 converter, a blue rectangular device with various ports and indicators.
Figure 1: A92Z ArtNet 1024 Bidirectional ArtNet Converter

Package Contents

Please verify that all items listed below are included in your package:

  • 1 x 2-way ArtNet Controller (A92Z ArtNet 1024)
  • 1 x Internet Cable (RJ45)
  • 1 x USB Drive (containing software and digital manual)
  • 1 x Power Plug (US Plug, AC100-240V)

Product Features

  • Bi-directional Conversion: Supports both ArtNet to DMX512 and DMX512 to ArtNet conversions.
  • High-Speed Processing: Utilizes high-speed ARM processors for efficient data handling.
  • Standard Connectivity: Equipped with an RJ45 Ethernet port and two standard DMX512 output interfaces.
  • Dual Operation Modes:
    • OUTPUT MODE (NODE MODE): Receives Art-Net signals via Ethernet and converts them to DMX512 signals.
    • INPUT MODE (SERVER MODE): Converts DMX512 signals to Art-Net signals for transmission over Ethernet.
  • Plug-and-Play: Factory-configured with a default IP address (e.g., 2.xxx) and subnet mask (255.0.0.0) for immediate use.
  • Configurable: Network settings can be modified using PC configuration tools or a web browser.
  • Robust Design: Durable metal and plastic construction with a distinctive blue finish.

Setup Guide

1. Component Identification

Front panel of the ArtNet converter showing DC-9-12V power input, RESET button, ON/OFF switches labeled 1 and 2, OUT and IN LEDs, PWR, STA, Link LEDs, and an Ethernet port.
Figure 2: Front Panel Overview
  • DC-9-12V: Power input port.
  • RESET: Button to reset the device.
  • ON/OFF Switches (1, 2): Configuration switches, typically used for setting DMX universe or operational parameters. Refer to the included software/manual for specific functions.
  • OUT LED: Indicates DMX output activity.
  • IN LED: Indicates DMX input activity.
  • PWR LED: Power indicator.
  • STA LED: Status indicator.
  • Link LED: Ethernet link status indicator.
  • Ethernet: RJ45 port for network connection.
Back panel of the ArtNet converter showing DMX1 and DMX2 ports with their pinout labels (1=GND, 2=(-), 3=(+)).
Figure 3: Back Panel Overview (DMX Ports)
  • DMX1, DMX2: Standard DMX512 3-pin XLR ports.
    • Pin 1: GND (Ground)
    • Pin 2: - (Data Negative)
    • Pin 3: + (Data Positive)

2. Initial Connection

  1. Power Connection: Connect the provided power adapter to the DC-9-12V port on the converter and plug it into a suitable AC100-240V power outlet. The PWR LED should illuminate.
  2. Network Connection: Use the provided internet cable to connect the Ethernet port on the converter to your network switch or directly to your computer's network port. The Link LED should illuminate, indicating a successful network connection.
  3. DMX Connection:
    • For OUTPUT MODE (ArtNet to DMX): Connect your DMX-controlled lighting fixtures to the DMX1 and/or DMX2 ports using standard DMX cables.
    • For INPUT MODE (DMX to ArtNet): Connect your DMX controller or DMX source to the DMX1 and/or DMX2 ports.

3. Network Configuration

The device is factory-configured with a default IP address (e.g., 2.xxx) and a subnet mask of 255.0.0.0. For most plug-and-play scenarios, no immediate modification is required if your network is within the same IP range.

If your network requires a different IP configuration, or for advanced settings, use the software provided on the included USB drive. This software allows you to modify network parameters and other device settings via a PC or a web browser interface.

Important: Always refer to the detailed instructions in the digital manual on the USB drive for specific software usage and advanced configuration.

Operating Modes

The A92Z ArtNet 1024 converter supports two primary operational modes:

1. OUTPUT MODE (NODE MODE)

In this mode, the converter acts as an ArtNet node, receiving Art-Net data over the Ethernet network and converting it into DMX512 signals. These DMX signals are then sent out through the DMX1 and DMX2 ports to control your lighting fixtures.

  • Function: ArtNet (Ethernet) → DMX512 (XLR)
  • Typical Use: Controlling DMX fixtures from ArtNet-compatible lighting control software or consoles.
  • Indicators: The OUT LED will flash to indicate DMX output activity.

2. INPUT MODE (SERVER MODE)

In this mode, the converter acts as a DMX server, receiving DMX512 signals from a DMX controller or other DMX source via the DMX1 and DMX2 ports. It then converts these DMX signals into Art-Net data and transmits them over the Ethernet network.

  • Function: DMX512 (XLR) → ArtNet (Ethernet)
  • Typical Use: Integrating traditional DMX consoles into an ArtNet network, or capturing DMX data for analysis.
  • Indicators: The IN LED will flash to indicate DMX input activity.

Note: The specific method for switching between INPUT and OUTPUT modes, and configuring DMX universes for each port, is typically managed through the configuration software provided on the USB drive. The ON/OFF switches (1, 2) on the front panel may also play a role in these settings; consult the digital manual for precise instructions.

Maintenance

  • Cleaning: Use a soft, dry cloth to clean the exterior of the device. Do not use liquid cleaners or solvents.
  • Ventilation: Ensure the device is placed in a well-ventilated area to prevent overheating. Do not block the cooling fins on the sides.
  • Storage: When not in use for extended periods, store the converter in a cool, dry place, away from direct sunlight and extreme temperatures.
  • Firmware Updates: Periodically check the manufacturer's website or the included software for any available firmware updates to ensure optimal performance and compatibility.

Troubleshooting

ProblemPossible CauseSolution
No Power (PWR LED off)Power adapter not connected or faulty; power outlet not active.Check power connections. Ensure the power outlet is working. Try a different power adapter if available.
No Network Link (Link LED off)Ethernet cable disconnected or faulty; network switch/router issue; incorrect IP settings.Verify Ethernet cable connection. Try a different cable or port. Check network switch/router status. Confirm IP settings using the configuration software.
No DMX Output/Input (OUT/IN LEDs inactive)Incorrect operating mode; DMX cable issue; software configuration error; DMX source/fixture problem.Ensure the converter is in the correct operating mode (INPUT/OUTPUT). Check DMX cable connections and integrity. Verify DMX universe settings in your lighting software and on the converter. Test DMX source/fixture independently.
Device unresponsiveSoftware crash; temporary glitch.Press the RESET button. If issues persist, power cycle the device (unplug and replug power).

Specifications

FeatureDetail
ModelA92Z ArtNet 1024
BrandFGHGF
Input VoltageAC100-240V
ProcessorHigh-speed ARM
Network Interface1 x RJ45 Ethernet
DMX Output/Input2 x DMX512 (3-pin XLR)
DMX Channels1024 (2 Universes of 512)
Protocol SupportArtNet
MaterialMetal + Plastic
ColorBlue
Dimensions (L x W x H)14 cm x 14 cm x 6 cm (approx.)
Weight0.396 kg (approx.)

User Tips

  • Software Compatibility: The A92Z ArtNet 1024 converter is designed to be highly compliant with the ArtNet protocol standard. This generally means it should work with various open-source lighting control software that supports ArtNet, such as QLC+ or Freestyler DMX. Ensure your software is configured to send/receive ArtNet data on the correct IP address and universe.
  • IP Address Management: While the device is plug-and-play with its default IP, for complex network setups or to avoid conflicts, it is recommended to use the provided configuration tools to assign a static IP address within your network's range.
  • Digital Manual: The included USB drive contains a digital manual and configuration software. Always refer to this resource for the most detailed and up-to-date instructions on advanced features and settings.

Warranty and Support

For technical support, troubleshooting assistance beyond this manual, or warranty inquiries, please contact the seller or manufacturer directly. Keep your purchase receipt as proof of purchase.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.