1. Introduction
This manual provides detailed instructions for the installation, operation, and maintenance of your DC12-50V 2 Channel RF Wireless Remote Control Receiver Kit. This versatile kit, comprising the AK-RK02E receiver and AK-BYD02 remote control, is designed for a wide range of applications including controlling LED light strips, electric door locks, motors, and exhaust systems. It features multiple operating modes (point action, self-locking, interlocking) and a wide voltage input range for broad compatibility.

This image shows the complete kit, including the white remote control and the green receiver board.
2. Specifications
Receiver (Model: AK-RK02E)
| Attribute | Value |
|---|---|
| Operating Voltage | DC12-36V |
| Standby Current | 9.8mA |
| Operating Frequency | 433MHz |
| Receiving Sensitivity | -105dBm |
| Demodulation | ASK |
| Dimensions | 68 x 48 x 18mm |
| Weight | 35.4g |
| Channel | 2 |
| Wireless Communication | RF |
| Certification | CE, FCC, RoHS, UL |
Transmitter (Remote Control, Model: AK-BYD02)
| Attribute | Value |
|---|---|
| Operating Voltage | DC6V |
| Transmit Current | 14.6mA |
| Transmit Power | 5-8dBm |
| Working Distance | Up to 50m (open area) |
| Operating Frequency | 433MHz |
| Dimensions | 59 x 34 x 11.5mm |
| Weight | 17.87g |

This image provides the physical measurements of the remote control unit.
3. Package Contents
Depending on your selection, your package may include:
- Remote control (AK-BYD02) x 1 (includes product operation manual x 1 + button cell batteries 2016 x 2)
- Receiver (AK-RK02E) x 1 (includes product operation manual x 1)
4. Setup and Wiring
The AK-RK02E receiver supports a wide voltage input (DC12-36V) and offers various operating modes. Ensure all connections are secure and correct before applying power.
4.1. Wiring Diagrams
The receiver board has terminals for power input (V+, V-) and two channels of output (NO1, C1, NC1, NO2, C2, NC2). Refer to the diagrams below for common wiring configurations.

This diagram illustrates how to connect two loads (e.g., lights) for switching signal output. Power (L and N) is supplied to the V+ and V- terminals. The loads are connected between the Common (C1/C2) and Normally Open (NO1/NO2) terminals.

This diagram shows connections for charged output, where the power for the loads is also derived from the receiver's input power. Loads are connected between C1/NO1 and C2/NO2, with the input power also feeding the loads directly.

This image provides a detailed view of the receiver board, including the terminal block for wiring and the 'LEARN' and 'MODEL' buttons.
4.2. Learning and Operating Modes
The receiver supports three operating modes: Point Action (Momentary), Self-locking (Toggle), and Interlocking (Latched). The mode is selected by pressing the 'MODEL' button on the receiver board, and remote controls are paired using the 'LEARN' button.

This image clearly shows the location of the 'LEARN' and 'MODEL' buttons on the receiver board, essential for configuration.
4.2.1. Pairing Remote Controls (Learning)
- Clear Existing Codes: Press and hold the 'LEARN' button on the receiver board for approximately 8 seconds until the indicator light flashes rapidly and then turns off. This clears all previously learned remote controls.
- Enter Learning Mode: Press the 'LEARN' button once. The indicator light will turn on, indicating it's ready to learn.
- Pair Remote: Press any button on your AK-BYD02 remote control. The indicator light on the receiver will flash once and then turn off, confirming successful pairing.
- Test: Press the remote control button again to verify operation.
4.2.2. Setting Operating Modes
The 'MODEL' button is used to cycle through the operating modes. Each press changes the mode. The indicator light behavior will confirm the selected mode.
- Point Action (Momentary): Press and hold the remote button to activate the relay; release to deactivate.
- Self-locking (Toggle): Press the remote button once to activate the relay; press again to deactivate.
- Interlocking (Latched): Press button 'A' to activate relay 1 and deactivate relay 2. Press button 'B' to activate relay 2 and deactivate relay 1.
Refer to the receiver's specific instructions for the exact sequence of 'MODEL' button presses to select each mode, as this can vary slightly between versions.
5. Operating the Device
Once the receiver is wired and the remote control is paired and configured to the desired operating mode, you can begin using the system.
- Power On: Ensure the receiver is powered within its DC12-36V operating range.
- Remote Control: Use the 'A' and 'B' buttons on the AK-BYD02 remote control to operate the connected devices according to the selected operating mode (Momentary, Toggle, or Latched).
- Range: The remote control has a working distance of up to 50 meters in open areas. Obstacles and interference may reduce this range.

This image displays the front of the remote control with its two primary buttons, 'A' and 'B'.

This diagram shows how the remote control system can be used for various applications like LED lighting, electric door locks, motors, and exhaust systems.
6. Maintenance
- Cleaning: Keep the receiver board and remote control clean and free from dust and moisture. Use a dry, soft cloth for cleaning.
- Battery Replacement: The AK-BYD02 remote control uses 2016 button cell batteries. Replace them when the remote's range decreases or it stops responding.
- Environmental Conditions: Avoid exposing the devices to extreme temperatures, direct sunlight, or corrosive environments.
7. Troubleshooting
- Device not responding to remote control:
- Check if the remote control batteries are dead and replace them if necessary.
- Ensure the remote control is within the effective operating range of the receiver.
- Verify that the remote control is properly paired with the receiver. If unsure, try re-pairing it following the instructions in Section 4.2.1.
- Check for strong RF interference in the area that might be blocking the signal.
- Connected device not turning on/off:
- Confirm that the receiver is receiving power (check wiring to V+ and V-).
- Inspect the wiring connections between the receiver's output terminals (NO/C/NC) and your connected device. Ensure they are secure and correct according to the chosen wiring diagram.
- Verify that the operating mode (Momentary, Toggle, Latched) is correctly set for your application.
- Ensure the connected device itself is functional and properly powered.
- Short operating range:
- Replace the remote control batteries.
- Ensure there are no large metal objects or thick walls obstructing the signal path between the remote and receiver.
- Avoid placing the receiver near other electronic devices that might cause RF interference.
8. User Tips
- For optimal performance, mount the receiver in a location free from excessive metal enclosures or other RF-blocking materials.
- When pairing multiple remotes, ensure each remote is learned individually.
- Always test the functionality after making any changes to wiring or operating modes.
- Consider the power requirements of your connected devices to ensure they are compatible with the receiver's relay capacity (e.g., 10A 250VAC / 10A 125VAC / 10A 30VDC / 10A 28VDC).
9. Warranty and Support