1. Introduction
This manual provides essential information for the safe and effective operation of your Hantek DSO5072P, DSO5102P, or DSO5202P Digital Storage Oscilloscope. Please read this manual thoroughly before using the device and keep it for future reference.

2. Safety Information
WARNING: HAZARDOUS VOLTAGE INSIDE. DO NOT REMOVE THE COVER UNLESS BY SPECIFIED PERSONNEL.
Always ensure the device is connected to a power source within the specified voltage and frequency range (AC 100-240V, 45-440Hz, 30W MAX). Use only the provided power cable and accessories. Do not operate the device in wet conditions or near flammable materials. Refer all servicing to qualified personnel.

3. Key Features
- Bandwidth Options: 70MHz (DSO5072P), 100MHz (DSO5102P), 200MHz (DSO5202P)
- Channels: 2 Digital Channels
- Real-Time Sample Rate: 1GSa/s
- Display: Large 7.0-inch color WVGA (800x480) TFT LCD
- Record Length: Up to 40K points
- Trigger Modes: Edge, Pulse Width, Line Selectable Video, Slope, Overtime, etc.
- Connectivity: USB Host and Device for PC connection and data storage
- Measurements: Multiple automatic measurements
- Math Functions: Four math functions, including FFT (Fast Fourier Transform)
- PC Software: Provides software for PC real-time analysis and control
4. Package Contents
Verify that all items listed below are included in your package:
- Hantek Digital Storage Oscilloscope Unit (DSO5072P, DSO5102P, or DSO5202P)
- 2 x Oscilloscope Probes
- 1 x USB Cable
- 1 x Power Cable
- 1 x CD (containing PC software and electronic manual)
- 1 x Printed Quick Start Guide/Manual
- Small accessories (e.g., probe color rings, adjustment tool)

5. Setup
5.1 Physical Placement
Place the oscilloscope on a stable, flat surface. Ensure adequate ventilation around the unit. The device features adjustable feet for optimal viewing angle.

5.2 Power Connection
- Connect the provided power cable to the AC input on the rear panel of the oscilloscope.
- Plug the other end of the power cable into a suitable AC power outlet (100-240V, 45-440Hz).
5.3 Probe Connection
- Connect the BNC connector of the oscilloscope probe to either the CH1 or CH2 input on the front panel.
- Ensure the probe is securely twisted into place.
- Attach the ground clip of the probe to the circuit's ground.
- Connect the probe tip to the test point on your circuit.
5.4 Initial Power-On
Press the power button located on the front panel to turn on the oscilloscope. The device will perform a self-test and display the main waveform interface.
6. Operation
6.1 Front Panel Overview

The front panel features a 7-inch display, various control knobs (Vertical, Horizontal, Trigger), and function buttons (Menu, Measure, Acquire, Display, Utility, Cursor, Save/Recall, Auto Set, Run/Stop, Single Seq, Trigger Level).
6.2 Basic Waveform Display
After connecting a probe to a signal source, press the AUTO SET button for automatic waveform optimization. Adjust the VERTICAL POSITION and VOLTS/DIV knobs to scale the vertical axis, and the HORIZONTAL POSITION and SEC/DIV knobs to scale the horizontal axis.

6.3 Trigger System
The trigger system stabilizes repetitive waveforms and captures single-shot events. Use the TRIGGER LEVEL knob to adjust the trigger threshold. Press the TRIGGER MENU button to access various trigger types:
- Edge Trigger: Triggers on the rising or falling edge of a signal.
- Pulse Width Trigger: Triggers on pulses of a specified width.
- Video Trigger: Triggers on standard video signals.
- Slope Trigger: Triggers on a specific slope of the waveform.
- Overtime Trigger: Triggers when a signal remains high or low for a specified duration.
6.4 Measurements
The oscilloscope supports multiple automatic measurements and cursor measurements.
- Automatic Measurements: Press the MEASURE button to display a menu of automatic measurements such as Frequency, Period, Max, Min, Peak-to-Peak Voltage (Pk-Pk), Rise Time, Fall Time, etc.
- Cursor Measurements: Press the CURSOR button to activate cursors. Use the multi-function knob to position the cursors and read voltage (ΔV) and time (ΔT) differences directly on the screen.

6.5 Math Functions
Press the MATH MENU button to access mathematical operations on waveforms, including addition, subtraction, multiplication, division, and FFT (Fast Fourier Transform) for frequency domain analysis.
6.6 USB Connectivity
The oscilloscope features a USB host port for saving waveforms and settings to a USB flash drive, and a USB device port for connecting to a PC for remote control and data analysis using the provided software.
7. Specifications
7.1 General Specifications
| Feature | Description |
|---|---|
| Display | 7 inch 64K color TFT (diagonal liquid crystal), 800*480 pixels, Adjustable (16 gears) with the progress bar |
| Probe Compensator Output | About 5Vpp into >1MΩ load, 1kHz |
| Power Supply | 100-120VACRMS(±10%), 45Hz to 440Hz, CAT II; 220-240VACRMS(±10%), 45Hz to 65Hz, CAT II |
| Power Consumption | <30W |
| Fuse | 2A, T rating, 250V |
| Operating Temperature | 32°F to 122°F (0°C to 50°C) |
| Nonoperating Temperature | -40°F to 158.8°F (-40°C to +71°C) |
| Cooling Method | Convection |
| Humidity | +104°F or below (+40°C or below): ≤90% RH; 104°F to 122°F (+41°C to 50°C): ≤60% RH |
| Operating Altitude | Below 3,000m (10,000 feet) |
| Nonoperating Altitude | Below 15,000m (50,000 feet) |
| Size (L×W×H) | 313mm x 108mm x 142mm |
| Weight | 2.08KG (Without Packing) |

7.2 Performance Specifications
| Feature | DSO5202P | DSO5102P | DSO5072P |
|---|---|---|---|
| Sample Rate | Real-Time: 1GSa/s; Equivalent Sample: 25GS/s | ||
| Acquisition Modes | Normal, Only data, High-frequency and random glitch capture | ||
| Average | Waveform Average, selectable 4, 8, 16, 32, 64, 128 | ||
| Inputs Coupling | AC, DC, GND | ||
| Inputs Impedance | 1MΩ±2% || 20pF±3pF | ||
| Probe Attenuation | 1X, 10X, 100X, 1000X | ||
| Supported Probe Attenuation Factor | 1X, 10X, 100X, 1000X | ||
| Maximum Input Voltage | CAT I and CAT II: 300V RMS (10×); Installation Category: CAT III: 150V RMS (1×) | ||
| Sample Rate Range | 500MS/s - 1GS/s | ||
| Waveform Interpolation | (sin X)/X | ||
| Record Length | 40K | ||
| SEC/DIV Range | 2ns/div to 80s/div | ||
| Bandwidth | 200MHz | 100MHz | 70MHz |
| Rise Time at BNC (Typical) | 1.8ns | 3.5ns | 5ns |
| Math | +, -, *, /, FFT | ||
| FFT Windows | Hanning, Flattop, Rectangular, Bartlett, Blackman; 1024 sample point | ||
| Bandwidth Limit | 20MHz | ||
| Low Frequency Response (-3db) | ≤10Hz at BNC | ||
| Trigger Modes | Auto, Normal, Single | ||
| Trigger Coupling Type | DC, AC, Noise Reject, HF Reject, LF Reject | ||
| Trigger Frequency Counter | 6 digits | ||
| Frequency Range | AC coupled, from 4Hz minimum to rated bandwidth | ||


8. Troubleshooting
8.1 No Display After Power On
- Ensure the power cable is securely connected to both the oscilloscope and the power outlet.
- Verify the power outlet is functional.
- Check the fuse on the rear panel (2A, T rating, 250V). Replace if blown.
8.2 No Waveform Displayed
- Check if the probe is correctly connected to the input channel (CH1/CH2) and the signal source.
- Ensure the probe's ground clip is connected to the circuit's ground.
- Press the AUTO SET button to automatically adjust settings.
- Adjust the VOLTS/DIV and SEC/DIV knobs to appropriate ranges.
- Verify the trigger settings. If the trigger level is outside the waveform's amplitude, the waveform may not be stable. Adjust the TRIGGER LEVEL knob.
- Ensure the input signal is within the oscilloscope's voltage limits.
8.3 Unstable Waveform
- Adjust the trigger level and trigger type to match the input signal characteristics.
- Check the probe compensation. Improper compensation can distort the waveform.
- Ensure the signal source is stable.
9. Maintenance
- Cleaning: Clean the exterior of the oscilloscope with a soft, damp cloth. Do not use abrasive cleaners or solvents. Ensure no liquid enters the device.
- Storage: Store the oscilloscope in a dry, dust-free environment when not in use. Avoid extreme temperatures and humidity.
- Probe Care: Handle probes carefully. Avoid bending or stressing the cable. Regularly check probe tips for damage.
- Software Updates: Check the manufacturer's website periodically for firmware and software updates to ensure optimal performance and access to new features.
10. User Tips
- Probe Compensation: For accurate measurements, always compensate your probes when first connecting them to the oscilloscope or if you suspect inaccuracies. Connect the probe to the probe compensator output (usually a square wave signal) and adjust the probe's compensation screw until the square wave is flat-topped.
- Grounding: Proper grounding is crucial for accurate and safe measurements. Always connect the probe's ground clip to the circuit's ground reference.
- USB Data Transfer: When saving waveforms or screenshots to a USB drive, ensure the drive is formatted to FAT32 for best compatibility.
- PC Software: Utilize the PC software for advanced analysis, remote control, and easier data logging, especially for long-term observations or complex signal processing.
11. Warranty and Support
For warranty information, technical support, or service inquiries, please refer to the contact information provided with your purchase documentation or visit the official Hantek website. Keep your purchase receipt as proof of purchase for warranty claims.