Coolmay TK8070H

Contents

Coolmay TK8070H HMI Touch Screen User Manual

Model: TK8070H | Brand: Coolmay

1. Introduction

Thank you for purchasing the Coolmay TK80 series touch screen. This manual provides essential information regarding the product characteristics, general specifications, hardware interfaces, and software setting methods for the TK8070H Human Machine Interface (HMI). For detailed programming instructions, please refer to the 'Coolmay TK80 Series (Vcool) Touch Screen User Manual' PDF document.

Play video
Watch video online

Video: Overview of Coolmay HMI Touch Screens, showcasing various sizes and features.

2. Product Overview

2.1 Key Features

  • High-Strength Performance Configuration: Features serial port isolation for stable communication, adaptability to complex interference environments, a Linux-based system for stability and security, and a high-performance Cortex A7 processor up to 1GHz. Includes 256MB FLASH + 256MB DDR3, with support for external USB and SD card storage.
  • Diversified Functional Modules: Supports multiple sets of formulas, window functions, data collection, and data alarm functions. Macro instructions can be developed using C language. Supports Chinese and English input, with up to 50 languages for Windows display. Compatible with common PLC communication protocols.
  • Complete Interface Embedding: Supports multiple communication methods (RS232/RS485, Ethernet), and various download options including USB, serial port, and Ethernet.
  • Advanced Password Mechanism: Includes configuration file encryption, installment payment, and HMI protection for enhanced security.

2.2 Product Structure

The TK8070H is part of the TK80 series, designed for industrial control applications. Below are visual representations of the HMI unit.

Front view of Coolmay TK8070H HMI showing a password editor screen

Image: Front view of the TK8070H HMI with a password editor interface displayed.

Rear view of Coolmay TK8070H HMI showing ports and model information

Image: Rear view of the TK8070H HMI, detailing various ports and model identification.

Diagram showing different Coolmay HMI models and their components

Image: Figure 2 Product structure - Illustrates various TK80 series HMI models and their key components.

3. Specifications

Item Description
ModelTK8070H/HD
Display Size7 inch
Resolution800*480
Working Environment TemperatureAmbient: 0~50℃ | Storage: -20~70℃
Working Environment Humidity20~90% (non-condensing)
RAM / ROM256MB / 256MB
CPU1GHz
USB Download PortYes (Type C programming port)
SD Card PortYes (optional, except for TK8037H)
Serial InterfaceRS232/RS485
Input PowerDC24V (Normally DC24±10%VDC, can be customized for DC12V/DC5V)
Pressure Test500VAC for 1 minute
Protection LevelIP65 (front panel)
Contrast400:1
Allow Power OutageWithin 20ms
System DiagnosticsPower failure detection
CertificationCE
FCC ComplianceCompliant with FCC Class A
Anti-interference TestVoltage 1500Vp-p, pulse period 1 us, lasting for 1 second
Shockproof Test10-25Hz (2G in X, Y, Z directions for 30 minutes)
Insulation ResistanceOver 10MΩ @ 500VDC
Touch Panel4-wire resistance screen

4. Setup

4.1 Installation Dimensions

Refer to the diagram below for mechanical dimensions and installation cut-out sizes for various TK80 series models. Ensure adequate space for ventilation and cable routing.

Figure 1 Installation dimensions diagram for TK80 series HMIs

Image: Figure 1 Installation dimensions diagram - Provides detailed measurements for various TK80 series HMI models.

4.2 Hardware Interface

The TK8070H features multiple ports for power, communication, and programming. Below are the pin definitions and interface layouts.

Hardware interface diagram for TK80 series HMIs showing various ports and pinouts

Image: Hardware interface diagram - Details the layout and pin assignments for RS232, RS485, USB, and power ports on TK80 series HMIs.

RS232 Communication Port Definition

Pin Number Signal Description
2RXDReceive
3TXDSend
5GNDGround wire

RS485 Communication Port Definition

Pin Number Signal Description
A485+Positive data line
B485-Negative data line

5. Operating Instructions

The TK8070H HMI can be connected to various PLCs. Below are instructions for configuring the Vcool software and wiring diagrams for common PLC brands.

5.1 Software Parameter Settings

The Vcool software allows adding two different protocols to communicate with two serial devices simultaneously. COM1 typically indicates RS232, and COM2 indicates RS485.

Selection of Human-Machine Interface Parameters (Landscape)

Landscape Signal Human Machine Interface Parameters (Landscape)
TK8037HTK8037H [320*240]
TK8043HTK8043H [480*272]
TK8050HTK8050H [800*480]
TK8070HTK8070H [800*480]
TK8070HDTK8070HD [1024*600]
TK8100HTK8100H [1024*600]
TK8150HTK8150H [1024*768]

5.2 Connecting to PLCs of Various Brands

For detailed programming and specific communication settings, please refer to the official 'Coolmay TK80 Series (Vcool) User Manual' available as a PDF: View User Manual (PDF).

Below are general guidelines and connection diagrams for common PLC types:

Section 1: Coolmay CX Series

RS232 Connection:

  • Vcool software settings: Communication protocol: CoolMay PLC(3U/3G)/FX3U, Port: COM1, Baud rate: 9600, Data bits: 7, Check bit: EVEN, Stop bit: 1.
  • HMI and Coolmay CX/MX series PLC RS232 communication line connection diagram (using "CX2N download cable").

RS485 Connection:

  • Vcool software settings: Communication protocol: CoolMay PLC(3U/3G)/FX3U, Port: COM2, Baud rate: 9600, Data bits: 7, Check bit: EVEN, Stop bit: 1.
  • HMI and Coolmay CX/MX series PLC RS485 communication line connection diagram.

Note: For TK8037H communication, use "customized line for communication with DX2N (FX2NC) PLC" or "customized line for communication with CX2N PLC" depending on your specific Coolmay FX/CX series PLC.

Section 2: Panasonic FP Series

  • Vcool software settings: Communication protocol: Matsushita FP Series, Port: COM1, Baud rate: 9600, Data bits: 8, Check bit: ODD, Stop bit: 1.
  • Connection diagram of HMI and Panasonic series PLC communication line.

Section 3: Xinjie PLC Series

  • Vcool software settings: Communication protocol: Xinje Electronic/Thinget XC Series, Port: COM1, Baud rate: 19200, Data bits: 8, Check bit: EVEN, Stop bit: 1.
  • Connection diagram of HMI and Xinjie series PLC communication line.

Section 4: Omron C Series

  • Vcool software settings: PLC type: Omron C/CPM/CP/CS/CJ Series, Communication port type: RS232, Data bits: 7, Stop bit: 2, Check bit: Even, Baud rate: 9600, Controller ID: 0.
  • Vcool (COM1)-Omron PLC communication line connection diagram.

Section 5: Siemens S7-200 Series

  • Vcool software settings: PLC type: Siemens S7-200 Series, Port: COM2, Baud rate: 9600, Data bits: 8, Check bit: EVEN, Stop bit: 1.
  • HMI (COM2) S7-200 series communication line connection diagram.

Section 6: Mitsubishi FX Series

  • Vcool software settings: PLC type: Mitsubishi FX Series, Port: COM1, Baud rate: 9600, Data bits: 7, Check bit: EVEN, Stop bit: 1.
  • HMI (COM1) and FX series PLC communication line connection diagram (using Mitsubishi programming cable such as SC-11).
Wiring diagrams for connecting Coolmay HMI to various PLC brands

Image: Instructions for connecting touch screen with PLC of various brands - Provides visual guides for wiring the HMI to different PLC systems.

6. Maintenance and Troubleshooting Tips

To ensure the longevity and proper functioning of your TK80 series HMI, please adhere to the following guidelines:

  • Power On: Always confirm the voltage (24VDC, 18W) and ensure correct wiring before powering on to prevent damage.
  • Mounting: Tighten all screws or secure the rail properly when mounting the product to avoid it falling off.
  • Wiring Safety: Avoid wiring or plugging cables while electricity is present to prevent electric shock or circuit damage.
  • Abnormal Operation: If the product emits an odor or abnormal sound, immediately switch off the power.
  • Prevent Contamination: When processing screw holes or wiring, ensure no metal chips or wire heads fall into the ventilation holes or the controller, as this can cause product failure and disoperation.
  • Grounding: Properly ground the FG terminals on the HMI to improve anti-interference ability.
  • Modifications: Do not disassemble the product or modify its wiring. Unauthorized alterations may lead to malfunction, loss, or fire.
  • Installation/Disassembly: Always turn off all power before installing or disassembling the product.

7. User Tips

Based on common user experiences, here are some tips for optimal use:

  • Regularly back up your HMI configuration files to prevent data loss.
  • Keep the HMI screen clean using a soft, dry cloth. Avoid abrasive cleaners.
  • Ensure the operating environment adheres to the specified temperature and humidity ranges for stable performance.
  • Familiarize yourself with the Vcool programming software for efficient project development and debugging.

8. Warranty and Support

8.1 Warranty Information

  • 18-Month Manufacturer Warranty: Covers hardware defects and system malfunctions under normal use from the date of purchase.

8.2 Technical Support

  • Lifetime Technical Support: Remote assistance is available for configuration, firmware updates, and integration queries.
  • Contact Us: Feel free to reach out for support, documentation, or firmware files. We aim to respond within 24 hours.

Shenzhen Coolmay Technology Co., Ltd.

  • Tel: 0755-86950416, 86960332, 26051858, 26400661
  • Fax: 0755-26400661-808
  • QQ: 800053919
  • E-mail: cm2@coolmay.net
  • Web: en.coolmay.com
Coolmay product certifications including CE and RoHS

Image: Certifications - Displays CE and RoHS compliance, and ISO 9001 quality management system certification.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.