1. Product Overview
The Midea KJR-86S/BK is a two-core wired control panel designed for central air conditioning systems. It provides convenient control over various functions of your air conditioning unit, ensuring optimal comfort and energy efficiency in your home or office environment. This manual will guide you through the installation, operation, and maintenance of your new controller.

2. Safety Information
- Always disconnect power to the air conditioning unit before installation or maintenance.
- Installation should be performed by a qualified electrician or HVAC technician.
- Ensure all wiring connections are secure and comply with local electrical codes.
- Do not expose the controller to water or excessive moisture.
- Do not attempt to repair the unit yourself. Contact qualified service personnel.
3. Installation and Setup
3.1 Package Contents
Before beginning installation, verify that all components are present:
- Midea KJR-86S/BK Wire Controller
- Mounting Back Plate
- Mounting Screws and Anchors
- Instruction Leaflet (may be in Chinese)

3.2 Mounting Location
Choose a suitable location for the controller, typically on an interior wall, away from direct sunlight, drafts, and heat sources that could affect temperature readings.
3.3 Wiring Instructions
The KJR-86S/BK controller uses a two-core wiring system. Ensure the power to the central air conditioning unit is OFF before proceeding.
- Carefully detach the front panel of the controller from its back plate.
- Mount the back plate securely to the wall using the provided screws and anchors.
- Connect the two-core communication wires from your central air conditioning unit to the designated terminals on the back plate. Refer to the wiring diagram provided with your specific AC unit for correct terminal identification.
- Ensure the wires are securely fastened and no bare wires are exposed.
- Carefully reattach the front panel to the mounted back plate, ensuring it clicks into place.

After installation, restore power to the air conditioning unit. The controller display should illuminate.
4. Operating Instructions
The Midea KJR-86S/BK controller features an intuitive interface with several buttons for easy operation.
4.1 Button Functions
- Power Button (top right): Turns the air conditioning unit ON or OFF.
- Menu Button (bottom left, three horizontal lines): Accesses advanced settings and modes. Press to cycle through options.
- Fan Speed Button (bottom, fan icon): Adjusts the fan speed (e.g., Low, Medium, High, Auto).
- Temperature Up/Down Arrows (bottom center, ▲/▼): Adjusts the desired temperature setting.
- Clock Button (bottom, clock icon): Sets the current time or schedules timer functions.
- Mode Button (bottom right, square with arrow): Cycles through operating modes (e.g., Cool, Heat, Fan, Dry, Auto).
4.2 Basic Operation
- Turning On/Off: Press the Power button.
- Setting Temperature: Use the Up (▲) or Down (▼) arrows to set your desired temperature.
- Changing Mode: Press the Mode button repeatedly until the desired operating mode (Cool, Heat, Fan, Dry, Auto) is displayed.
- Adjusting Fan Speed: Press the Fan Speed button to cycle through available fan speeds.
5. Maintenance
Regular maintenance ensures the longevity and optimal performance of your wire controller.
- Cleaning: Wipe the surface of the controller with a soft, dry cloth. Do not use abrasive cleaners, solvents, or chemical sprays, as these can damage the display or casing.
- Avoid Moisture: Keep the controller dry and away from areas with high humidity or potential water splashes.
- Inspect Wiring: Periodically check the wiring connections at the back plate to ensure they are secure and free from corrosion. (Ensure power is off before inspection).
6. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Controller display is blank. | No power to the unit or loose wiring. | Check the circuit breaker for the AC unit. Ensure all wiring connections are secure (power off first). |
| Air conditioner not responding to commands. | Incorrect wiring, communication error, or AC unit issue. | Verify wiring connections. Ensure the controller is compatible with your specific AC unit model. Restart the AC unit by cycling its power. |
| Temperature readings seem inaccurate. | Controller located in an unsuitable spot (e.g., direct sunlight, near a heat source). | Relocate the controller if possible, or consider if external factors are influencing the reading. |
7. Specifications
| Feature | Detail |
|---|---|
| Model Number | KJR-86S/BK (Universal model) |
| Type | Wire Controller / Damper / Air Conditioner Parts |
| Wiring | Two-core |
| Application | Home Central Air Conditioning Systems |
| Certification | CE |
| Origin | Mainland China |
| Package Dimensions (L x W x H) | 35 cm x 25 cm x 10 cm |
| Package Weight | 0.8 kg |
8. User Tips
- Compatibility Check: Before installation, always confirm that the KJR-86S/BK controller is compatible with your specific Midea central air conditioning unit model. Some AC units, especially larger tonnage models, may require specific controllers.
- Read AC Unit Manual: For detailed wiring diagrams and specific operational parameters, refer to the instruction manual of your Midea central air conditioning unit.
9. Warranty and Support
For warranty information, technical support, or service inquiries, please contact the seller, Master Repair Store, or refer to the documentation provided with your purchase. Keep your proof of purchase for warranty claims.
This product is certified with CE, indicating compliance with European health, safety, and environmental protection standards.