1. Introduction
Thank you for choosing the NJTY T88 series analog multimeter. This high-precision instrument is designed for various electrical measurements, including AC/DC voltage, DC current, and resistance. It features a clear pointer display and robust protection circuits, making it an essential tool for electrical DIY, maintenance, and testing.
This manual provides detailed instructions for the safe and effective use of your multimeter. Please read it thoroughly before operation and keep it for future reference.
2. Model Overview
The NJTY T88 series includes models T88A, T88B, and T88C, each offering specific features:

Figure 2.1: Comparison of T88A, T88B, and T88C Multimeter Models
| Feature | T-88A (Standard) | T-88B (Upgrade) | T-88C (Elite) |
|---|---|---|---|
| Gears | 24 | 24 | 24 |
| Magnetism | Internal Magnetic | Internal Magnetic | External Magnetism |
| Infrared Remote Control Detection | No | Yes | Yes |
| Firewire Identification | No | Yes | No |
| Resistance Measurement | Rx10k | Rx10k | Rx100k |
3. Product Components
Familiarize yourself with the parts of your multimeter:

Figure 3.1: T88C Multimeter Components
- Pointer Display: Analog scale for reading measurements.
- Pointer Zero Adjustment: Knob to set the pointer to zero before measurements.
- Resistance Zero Adjustment: Knob to calibrate resistance measurements.
- Function Gear Dial: Rotary switch to select measurement type and range.
- 2500V Voltage Jack: Input terminal for high voltage measurements.
- 10A Current Jack: Input terminal for high current measurements.
- Protective Soft Rubber Sleeve: Provides durability and grip.
- Transistor Jack: For testing transistors (hFE).
- Red Test Pen Socket: Positive (+) input for test leads.
- Black Test Pen Socket (COM): Common/Negative (-) input for test leads.
- Suspension Support/Back Magnet: For convenient placement and hands-free operation.
4. Setup and Initial Checks
4.1. Battery Installation
The multimeter requires two AAA batteries for operation. Follow these steps to install them:

Figure 4.1: Battery and Fuse Compartment
- Locate the battery compartment on the back of the multimeter.
- Open the battery cover.
- Insert two 1.5V AAA batteries, ensuring correct polarity.
- Close the battery cover securely.
The device is equipped with an anti-burning resettable fuse (voltage below 250V) and includes two spare fuses for easy replacement.
4.2. Connecting Test Leads
Insert the red test lead into the red test pen socket (+) and the black test lead into the black test pen socket (COM/-).
4.3. Pointer Zeroing
Before taking any measurements, especially for resistance, ensure the pointer is at the zero mark on the scale. Use the 'pointer zero adjustment' knob if necessary.
Video 4.1: Demonstrating pointer zero adjustment and various measurements.
5. Operating Instructions
Always select the appropriate function and range before connecting the test leads to the circuit. If the measurement value is unknown, start with the highest range and decrease it until a stable reading is obtained.
5.1. AC Voltage Measurement
- Set the function gear dial to the desired ACV range (e.g., 250V, 500V).
- Connect the test leads in parallel across the AC voltage source.
- Read the voltage value from the ACV scale on the pointer display.

Figure 5.1: AC Voltage Measurement. The display shows 226V.
5.2. DC Voltage Measurement
- Set the function gear dial to the desired DCV range (e.g., 10V, 50V).
- Connect the red test lead to the positive (+) side and the black test lead to the negative (-) side of the DC voltage source.
- Read the voltage value from the DCV scale on the pointer display.

Figure 5.2: DC Voltage Measurement. The display shows 9V.
5.3. Resistance Measurement
- Set the function gear dial to the desired resistance range (e.g., x1K, x10K).
- Before measuring, short the test leads together and adjust the 'resistance zero adjustment' knob until the pointer reads zero.
- Connect the test leads across the component to be measured.
- Read the resistance value from the Ω scale.

Figure 5.3: Resistance Measurement. The display shows 10kΩ.
5.4. Continuity Test (On and Off Beep)
- Set the function gear dial to the 'BUZZ' or continuity setting.
- Connect the test leads across the circuit or component.
- If the resistance is below approximately 30Ω, the multimeter will emit an audible beep, indicating continuity.
5.5. Diode/Transistor Test
- Set the function gear dial to the diode/transistor test setting.
- For diodes, connect the test leads across the diode. Observe the reading for forward and reverse bias. A 10k resistor can be used to light up a diode for visual confirmation.
- For transistors, use the transistor jack (hFE) to test NPN/PNP types.
5.6. Battery Charge Measurement
- Set the function gear dial to the 'BATT' range (e.g., 1.5V, 9V).
- Connect the red test lead to the positive (+) terminal and the black test lead to the negative (-) terminal of the battery.
- Read the battery voltage from the display.
5.7. Infrared Remote Control Detection (T88B/T88C only)
- Set the function gear dial to the infrared detection setting.
- Point the infrared emitter of a remote control towards the multimeter's IR sensor.
- Press a button on the remote. The multimeter will indicate if an infrared signal is detected.
5.8. Capacitor Good/Bad Test
- Select the appropriate gear for the resistor:
- Less than 0.01uF: choose x10K
- 1-10uF: choose x1K
- Above 10uF: choose x100 or x10 gear
- For each measurement, short-circuit the capacitor with a wire, and then perform the next measurement after discharging.
- For electrolytic capacitors, the positive electrode has higher than the negative electrode potential when in use. The black test lead is connected to the meter's common (COM) terminal. The positive lead of the battery is connected to the positive electrode of the electrolytic capacitor, and the red test lead is connected to the negative electrode of the capacitor.
6. Specifications

Figure 6.1: Detailed Specifications for T88A, T88B, T88C
| Parameter | Value |
|---|---|
| Operating Mode | Manual Range |
| Operating Temperature | 0 - 40 ℃ |
| DIY Supplies | Electrical |
| Certification | CE |
| Dimensions | 179*118*50mm |
| Display Type | Pointer Display |
| Power Supply | 1.5V AAA*2 |
| Weight | 400g |
| Circuit Board | Double-sided gold-plated circuit board |
| Protection | 24 files automatic protection, automatic recovery circuit, overload protection against false detection, quick-blow fuse tube |
| Function | Range | Accuracy |
|---|---|---|
| DC Voltage | 0.25V-1V-2.5V-10V-50V-250V-500V-1000V-2500V | ±5% |
| AC Voltage | 0-10V-50V-250V-500V-1000V-250V | ±5% |
| DC Current | 50uA-0.5mA-5mA-50mA-500mA-10A | ±5% |
| DC Resistance | Rx1-Rx10-Rx100-Rx1k-Rx10k-Rx100k | ±10% |
| Standard Resistance Box | 0.025/0.5/5/50/500/5k/20k/50k/200k/1M/2.25M/4.5M/9M/22.5M | N/A |
| Access Beep | Buzzer works when below 30Ω | N/A |
| LV Detection | Rx1-x1k-Rx1k | N/A |
| Zener Tube/LED Detection | Zener tube within 10V, detection current: DC 5mA (L type only) | N/A |
| Battery Power Infrared Remote Control Detection | 1.2V/1.5V/2V/3V/3.6V (Only A/B/C types) | N/A |
| Zero Line Resolution | Yes (Type B only) | N/A |
7. Maintenance
7.1. General Care
- Keep the multimeter clean and dry. Wipe the casing with a soft, damp cloth. Do not use abrasive cleaners or solvents.
- Store the multimeter in a cool, dry place away from direct sunlight and extreme temperatures.
- Avoid dropping the device or subjecting it to strong impacts.
7.2. Fuse Replacement
The multimeter is equipped with a quick-blow fuse for overload protection. If the multimeter stops functioning correctly, especially after an overload, the fuse may need replacement.

Figure 7.1: Fuse Location
- Ensure the multimeter is turned off and disconnected from any circuit.
- Open the battery compartment cover on the back of the device.
- Carefully remove the old fuse.
- Replace it with a new fuse of the correct rating (check the specifications or the old fuse for details). Spare fuses are typically located within the battery compartment.
- Close the battery compartment cover securely.
8. Troubleshooting
If your multimeter is not functioning as expected, consider the following common issues:
- No display/No power: Check if the batteries are correctly installed and have sufficient charge. Replace batteries if necessary.
- Incorrect readings: Ensure the function dial is set to the correct measurement type and range. Verify that the test leads are properly connected and not damaged. Perform pointer zeroing and resistance zero adjustment before measurement.
- No continuity beep: Check if the 'BUZZ' function is selected and if the circuit resistance is indeed below 30Ω.
- No response in a specific function: The fuse for that function range might be blown. Refer to Section 7.2 for fuse replacement.
If the problem persists after checking these points, contact customer support for further assistance.
9. User Tips
- Always start with a higher range when measuring an unknown value to prevent overloading the meter.
- Ensure good contact between the test probes and the circuit points for accurate readings.
- For resistance measurements, always disconnect power from the circuit and discharge any capacitors before testing.
- Utilize the suspension support or back magnet for hands-free operation when working on complex circuits.