ELECTESLA ES-D12 Variable Frequency Drive (VFD) User Manual

Model: ES-D12 | Brand: ELECTESLA

1. Introduction

The ELECTESLA ES-D12 Variable Frequency Drive (VFD) is designed to control the speed of AC motors by varying the frequency and voltage supplied to the motor. This manual provides essential information for the safe and efficient installation, operation, and maintenance of your VFD. Please read this manual thoroughly before using the product.

2. Safety Information

WARNING: Read the user manual before operation. Risk of electrical shock. Wait 10 minutes after removing power before servicing.

Always observe the following safety precautions to prevent personal injury or damage to the equipment:

  • Ensure the VFD is installed by qualified personnel only.
  • Disconnect all power sources before performing any wiring, inspection, or maintenance.
  • Verify that the input voltage matches the VFD's specifications.
  • Do not touch electrical components while the VFD is powered.
  • Ground the VFD properly to prevent electrical shock.
  • Protect the VFD from moisture, dust, and corrosive gases.
Two ELECTESLA ES-D12 VFD units, front view, displaying '0.00' and a warning label.
Figure 2.1: Front view of the ES-D12 VFD units, showing the display and safety warning.

3. Specifications

3.1 General Specifications

AttributeValue
Brand NameELECTESLA
Model NumberES-D12
TypeDC/AC Inverters
Input Voltage1-phase 220V (Allowed: 220V~240V); 3-phase 380V (Allowed: 380V~440V)
Output Voltage1-phase 0~240V; 3-phase 0~440V
Output FrequencyLow frequency mode: 0~60HZ; High frequency mode: 0~999HZ
Output Current2.5-10A (varies by power model)
Output Power0.75-2.2KW
Output TypeSINGLE
Control ModeV/F control
OverloadG type: 110% for long-term, 120% for 1 min, 150% for 5s
Weight1.5kgs
CertificationCE, FCC, RoHS
is_customizedYes

3.2 Model and Power Ratings

ModelPower (KW)Output Current (A)
Three phase 380V input Three Phase 380V output
D12-T3-0R7G0.753
D12-T3-1R5G1.54
D12-T3-2R2G2.25
Single phase 220V input Three Phase 220V output
D12-S2-0R4G0.42.5
D12-S2-0R7G0.755
D12-S2-1R5G1.57
D12-S2-2R2G2.210
Diagram showing the dimensions of the VFD units with a table of models and their corresponding W, W1, H, H1, D, D1, and Aperture measurements in mm.
Figure 3.1: Dimensions of the ES-D12 VFD models.

4. Product Overview and Components

The ELECTESLA ES-D12 VFD features a compact design with an intuitive control panel for easy operation. Key components include the display, control buttons, speed control knob, and various input/output terminals.

Front view of the VFD with labels pointing to its various controls: Muli-function key, Programming Key, Move Key, Run Key, Speed control knob, Enter key, Up selection key, Stop&Reset key, Down selection key, Current, Voltage.
Figure 4.1: Front panel and control keys of the ES-D12 VFD.

The rear of the unit houses the main power and motor connection terminals, along with control circuit terminals for external connections.

Bottom view of the VFD showing the terminal block for power and motor connections.
Figure 4.2: Bottom view showing the main terminal block.

5. Setup and Wiring

Proper wiring is critical for the safe and correct operation of the VFD. Refer to the diagrams and terminal descriptions below.

5.1 Main Circuit Terminals

Code of terminalTerminalFunction
RPower input for main circuitR/S/T3-phase, AC power input terminal, 380V, 50Hz/60Hz
S/L1L1/L2 220V Model connect terminals
T/L2
UOutput of frequency inverterTerminal for connection to motor
V
W
PConnection of braking resistorTerminal for connection to braking resistor
PB
Grounding symbolGroundingTerminal for grounding. 400V level: grounding resistance is 4Ω or below.

5.2 Control Circuit Terminals

Code of terminalTerminalFunction
GNDPublic terminal of the control circuit
10V10V output voltageCommonly used as working voltage of the external potentiometer. Maximum current: 10mA
12V12V output voltageCommonly used as working voltage of the logic input terminal. Maximum current: 10mA
AVIVoltage Analog input or Current Analog inputAnalog voltage input: 0~+10 V. Analog voltage input: 0/4~20mA. Set according to parameter F2.00~F2.03
X1Digital input X1Set according to parameter F2.13, and factory set defaults to be FWD.
X2Digital input X2Set according to parameter F2.14, and factory set defaults to be REV.
X3Digital input X3Set according to parameter F2.15, and factory set defaults to be IDLE.
X4Digital input X4Set according to parameter F2.16, and factory set defaults to be IDLE.
X5Digital input X5Set according to parameter F2.17, and factory set defaults to be Pulse Frequency Input.
TA-TB-TCRelay outputSet according to parameter F2.20. Contact rating: AC 250V/5A DC 24V/2.5A
Y1Open-collector outputDefault running indication
AOAnalog outputAnalog voltage input: 0~+10 V. Analog voltage input: 0/4~20mA. Set according to parameter F2.10~F2.12

5.3 Wiring Diagrams

Wiring diagrams for 220V and 380V input. The 220V diagram shows L1 and L2 connected to the VFD's L1 and L2 terminals, and the motor connected to U, V, W. The 380V diagram shows R, S, T connected to the VFD's R, S, T terminals, and the motor connected to U, V, W.
Figure 5.1: Basic power and motor wiring for 220V (single-phase input) and 380V (three-phase input) systems.
Detailed wiring diagram for the VFD, showing connections for power input, breaker, braking resistor, three-phase induction motor, multi-function terminals (FWD/STOP, REV/STOP, Fault Reset, Multi-Speed 1-2), common terminals, 10V output, AVI (current/voltage analog input), potentiometer, open collector output, analog output, RS485 communication, and relay output.
Figure 5.2: Comprehensive wiring diagram including control signals and communication.

6. Operating Instructions

The VFD is operated via its front panel controls. Familiarize yourself with the buttons and their functions.

6.1 Keyboard Functions

Diagram illustrating the VFD's operating keyboard with labels for Status indicator, Multifunctional keys, Menu, Shift key, UP&DOWN selection keys, Function, Current, Voltage, Speed control knob, Enter, Stop, Reset.
Figure 6.1: Operating Keyboard Instructions.
  • RUN Key: Starts the motor.
  • STOP/RESET Key: Stops the motor or resets fault conditions.
  • PRG (Programming) Key: Enters or exits parameter programming mode.
  • MF (Multi-function) Key: Used for various functions depending on the mode.
  • Up/Down Selection Keys: Navigate through menus or adjust parameter values.
  • ENTER Key: Confirms selections or parameter changes.
  • Speed Control Knob: Adjusts the output frequency/motor speed.

6.2 Basic Operation

  1. Power On: Ensure all wiring is correct and secure before applying power. The display will light up.
  2. Speed Adjustment: Use the Speed Control Knob to set the desired output frequency (displayed in Hz).
  3. Start Motor: Press the RUN button. The motor will accelerate to the set frequency.
  4. Stop Motor: Press the STOP/RESET button. The motor will decelerate and stop.
  5. Parameter Setting: Press the PRG key to enter programming mode. Use the Up/Down keys to select parameters, ENTER to view/edit, and the Speed Control Knob or Up/Down keys to change values. Press ENTER to save and PRG to exit.

6.3 Operation Demonstration Video

Video 6.1: Demonstration of the VFD controlling motor speed.

This video illustrates the process of adjusting the motor speed using the VFD's control knob and initiating/stopping the motor.

7. Maintenance

Regular maintenance ensures the longevity and reliable operation of your VFD.

  • Cleaning: Keep the VFD clean and free from dust and debris. Use a soft, dry cloth for cleaning. Do not use liquid cleaners.
  • Ventilation: Ensure adequate ventilation around the VFD to prevent overheating. Check that cooling fans (if present) are operating correctly and not obstructed.
  • Terminal Inspection: Periodically check all terminal connections for tightness. Loose connections can cause overheating and malfunction.
  • Environmental Conditions: Operate the VFD within its specified environmental conditions (temperature, humidity, altitude).

8. Troubleshooting

The VFD is equipped with protective functions to safeguard itself and the connected motor. If a fault occurs, the VFD will display an error code and stop operation. Common protective functions include:

  • Overcurrent
  • Overvoltage
  • Undervoltage
  • Module fault
  • Electric thermal relay trip
  • Overheat
  • Short circuit
  • Default phase of input and output
  • Motor parameter adjustment abnormality
  • Internal memory fault

If a fault occurs, first note the error code displayed. Then, disconnect power, wait 10 minutes, and check the wiring and motor for any obvious issues. Consult the full user manual (if available) for specific error code interpretations and troubleshooting steps. If the problem persists, contact technical support.

9. User Tips

  • For optimal performance, ensure the VFD is mounted in a location with good airflow and away from direct heat sources.
  • Always double-check wiring connections before applying power to prevent damage.
  • When adjusting parameters, make small incremental changes and observe the motor's response.

10. Applications

The ELECTESLA ES-D12 VFD is suitable for a wide range of industrial and commercial applications requiring precise motor speed control. Common applications include:

  • Fans
  • Water Pumps
  • Conveyors
  • Compressors
  • Machine Tools
  • Blenders
  • Injection Molding Machines
  • Cranes/Punches/Transveyors/Roots Blowers
  • Winches/Milling/Ball Mills/Drawbenches
Image showing various industrial applications of the inverter, including Fan, Water Pump, Conveyor, Compressor, Machine Tool, and Blender, with expanded specifications for each.
Figure 10.1: Scope of Inverter Applications.

11. Support

For any assistance, user manuals, or technical inquiries, please contact ELECTESLA support:

  • WhatsApp: +8619356149608
  • Email: whitney@jinqu-electric.com
Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.