1. Introduction
The ELECTESLA ES-D12 Variable Frequency Drive (VFD) is designed to control the speed of AC motors by varying the frequency and voltage supplied to the motor. This manual provides essential information for the safe and efficient installation, operation, and maintenance of your VFD. Please read this manual thoroughly before using the product.
2. Safety Information
WARNING: Read the user manual before operation. Risk of electrical shock. Wait 10 minutes after removing power before servicing.
Always observe the following safety precautions to prevent personal injury or damage to the equipment:
- Ensure the VFD is installed by qualified personnel only.
- Disconnect all power sources before performing any wiring, inspection, or maintenance.
- Verify that the input voltage matches the VFD's specifications.
- Do not touch electrical components while the VFD is powered.
- Ground the VFD properly to prevent electrical shock.
- Protect the VFD from moisture, dust, and corrosive gases.

3. Specifications
3.1 General Specifications
| Attribute | Value |
|---|---|
| Brand Name | ELECTESLA |
| Model Number | ES-D12 |
| Type | DC/AC Inverters |
| Input Voltage | 1-phase 220V (Allowed: 220V~240V); 3-phase 380V (Allowed: 380V~440V) |
| Output Voltage | 1-phase 0~240V; 3-phase 0~440V |
| Output Frequency | Low frequency mode: 0~60HZ; High frequency mode: 0~999HZ |
| Output Current | 2.5-10A (varies by power model) |
| Output Power | 0.75-2.2KW |
| Output Type | SINGLE |
| Control Mode | V/F control |
| Overload | G type: 110% for long-term, 120% for 1 min, 150% for 5s |
| Weight | 1.5kgs |
| Certification | CE, FCC, RoHS |
| is_customized | Yes |
3.2 Model and Power Ratings
| Model | Power (KW) | Output Current (A) |
|---|---|---|
| Three phase 380V input Three Phase 380V output | ||
| D12-T3-0R7G | 0.75 | 3 |
| D12-T3-1R5G | 1.5 | 4 |
| D12-T3-2R2G | 2.2 | 5 |
| Single phase 220V input Three Phase 220V output | ||
| D12-S2-0R4G | 0.4 | 2.5 |
| D12-S2-0R7G | 0.75 | 5 |
| D12-S2-1R5G | 1.5 | 7 |
| D12-S2-2R2G | 2.2 | 10 |

4. Product Overview and Components
The ELECTESLA ES-D12 VFD features a compact design with an intuitive control panel for easy operation. Key components include the display, control buttons, speed control knob, and various input/output terminals.

The rear of the unit houses the main power and motor connection terminals, along with control circuit terminals for external connections.

5. Setup and Wiring
Proper wiring is critical for the safe and correct operation of the VFD. Refer to the diagrams and terminal descriptions below.
5.1 Main Circuit Terminals
| Code of terminal | Terminal | Function |
|---|---|---|
| R | Power input for main circuit | R/S/T3-phase, AC power input terminal, 380V, 50Hz/60Hz |
| S/L1 | L1/L2 220V Model connect terminals | |
| T/L2 | ||
| U | Output of frequency inverter | Terminal for connection to motor |
| V | ||
| W | ||
| P | Connection of braking resistor | Terminal for connection to braking resistor |
| PB | ||
| Grounding | Terminal for grounding. 400V level: grounding resistance is 4Ω or below. |
5.2 Control Circuit Terminals
| Code of terminal | Terminal | Function |
|---|---|---|
| GND | Public terminal of the control circuit | |
| 10V | 10V output voltage | Commonly used as working voltage of the external potentiometer. Maximum current: 10mA |
| 12V | 12V output voltage | Commonly used as working voltage of the logic input terminal. Maximum current: 10mA |
| AVI | Voltage Analog input or Current Analog input | Analog voltage input: 0~+10 V. Analog voltage input: 0/4~20mA. Set according to parameter F2.00~F2.03 |
| X1 | Digital input X1 | Set according to parameter F2.13, and factory set defaults to be FWD. |
| X2 | Digital input X2 | Set according to parameter F2.14, and factory set defaults to be REV. |
| X3 | Digital input X3 | Set according to parameter F2.15, and factory set defaults to be IDLE. |
| X4 | Digital input X4 | Set according to parameter F2.16, and factory set defaults to be IDLE. |
| X5 | Digital input X5 | Set according to parameter F2.17, and factory set defaults to be Pulse Frequency Input. |
| TA-TB-TC | Relay output | Set according to parameter F2.20. Contact rating: AC 250V/5A DC 24V/2.5A |
| Y1 | Open-collector output | Default running indication |
| AO | Analog output | Analog voltage input: 0~+10 V. Analog voltage input: 0/4~20mA. Set according to parameter F2.10~F2.12 |
5.3 Wiring Diagrams


6. Operating Instructions
The VFD is operated via its front panel controls. Familiarize yourself with the buttons and their functions.
6.1 Keyboard Functions

- RUN Key: Starts the motor.
- STOP/RESET Key: Stops the motor or resets fault conditions.
- PRG (Programming) Key: Enters or exits parameter programming mode.
- MF (Multi-function) Key: Used for various functions depending on the mode.
- Up/Down Selection Keys: Navigate through menus or adjust parameter values.
- ENTER Key: Confirms selections or parameter changes.
- Speed Control Knob: Adjusts the output frequency/motor speed.
6.2 Basic Operation
- Power On: Ensure all wiring is correct and secure before applying power. The display will light up.
- Speed Adjustment: Use the Speed Control Knob to set the desired output frequency (displayed in Hz).
- Start Motor: Press the RUN button. The motor will accelerate to the set frequency.
- Stop Motor: Press the STOP/RESET button. The motor will decelerate and stop.
- Parameter Setting: Press the PRG key to enter programming mode. Use the Up/Down keys to select parameters, ENTER to view/edit, and the Speed Control Knob or Up/Down keys to change values. Press ENTER to save and PRG to exit.
6.3 Operation Demonstration Video
This video illustrates the process of adjusting the motor speed using the VFD's control knob and initiating/stopping the motor.
7. Maintenance
Regular maintenance ensures the longevity and reliable operation of your VFD.
- Cleaning: Keep the VFD clean and free from dust and debris. Use a soft, dry cloth for cleaning. Do not use liquid cleaners.
- Ventilation: Ensure adequate ventilation around the VFD to prevent overheating. Check that cooling fans (if present) are operating correctly and not obstructed.
- Terminal Inspection: Periodically check all terminal connections for tightness. Loose connections can cause overheating and malfunction.
- Environmental Conditions: Operate the VFD within its specified environmental conditions (temperature, humidity, altitude).
8. Troubleshooting
The VFD is equipped with protective functions to safeguard itself and the connected motor. If a fault occurs, the VFD will display an error code and stop operation. Common protective functions include:
- Overcurrent
- Overvoltage
- Undervoltage
- Module fault
- Electric thermal relay trip
- Overheat
- Short circuit
- Default phase of input and output
- Motor parameter adjustment abnormality
- Internal memory fault
If a fault occurs, first note the error code displayed. Then, disconnect power, wait 10 minutes, and check the wiring and motor for any obvious issues. Consult the full user manual (if available) for specific error code interpretations and troubleshooting steps. If the problem persists, contact technical support.
9. User Tips
- For optimal performance, ensure the VFD is mounted in a location with good airflow and away from direct heat sources.
- Always double-check wiring connections before applying power to prevent damage.
- When adjusting parameters, make small incremental changes and observe the motor's response.
10. Applications
The ELECTESLA ES-D12 VFD is suitable for a wide range of industrial and commercial applications requiring precise motor speed control. Common applications include:
- Fans
- Water Pumps
- Conveyors
- Compressors
- Machine Tools
- Blenders
- Injection Molding Machines
- Cranes/Punches/Transveyors/Roots Blowers
- Winches/Milling/Ball Mills/Drawbenches