Important Safety Information
Please read this manual carefully before installing or using your dehumidifier. Keep this instruction manual for future reference.
General Warnings
- Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
- The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater).
- Do not pierce or burn. Be aware the refrigerants may not contain an odour.
- Appliance shall be installed, operated and stored in a room with a floor area larger than 4 m².
- This appliance contains 52 g of R290 refrigerant gas. R290 is a refrigerant gas that complies with European directives on the environment. Do not puncture any part of the refrigerant circuit.
- If the appliance is installed, operated or stored in a non-ventilated area, the room must be designed to prevent the accumulation of refrigerant leaks resulting in a risk of fire or explosion due to ignition of the refrigerant caused by electric heaters, stoves, or other sources of ignition.
- The appliance must be stored in such a way as to prevent mechanical failure.
Safety Advice and Warnings
- This appliance may be used by children aged 8 years and over and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge, if they have been given appropriate supervision or training in the use of the appliance in a safe and understand the dangers involved.
- This appliance is not a toy. Children should be supervised to ensure that they do not play with the appliance.
- Do not allow children to perform cleaning and maintenance without supervision.
Electrical Connection Warnings
- Install the appliance in accordance with national wiring regulations.
- Before connecting the appliance, check that the voltage indicated on the nameplate matches the voltage on the rating plate.
- Connect the appliance to a power socket that supports at least 10 amps.
- The appliance plug must match the electrical socket of the socket. Never modify the plug. Do not use plug adapters.
- Do not force the connecting cable. Never use the power cord to lift, carry or unplug the appliance.
- Check that the power cord is not pinched or bent.
- Do not allow the connecting cord to hang or touch the hot surfaces of the appliance.
- Do not touch the plug with wet hands.
- Do not use the appliance with a damaged power cord or plug.
Product Overview
The SHINCO Dehumidifier is designed to efficiently remove moisture from the air, improving comfort and air quality in your home. It features a user-friendly control panel and multiple operating modes.

Parts Description
Refer to the diagram below for an overview of the dehumidifier's components:

The main components are:
- Handle
- Control Panel
- Front Panel
- Back Panel
- Water Tank
- Casters
- Filter Frame
- Drainage Outlet
- Power Cord Storage Column
- Drainage Hose
- Active Carbon Filter
Control Panel
The control panel features the following buttons and indicators:
- Timer
- Clean Function
- Fan Speed (High/Low)
- Full Tank Indicator (flashing when full)
- LED Display
- Humidity Setting Button
- Mode Selection (Auto/Laundry)
- ON/OFF Button
Setup
Unpacking and Initial Use
- Be sure to remove all packaging material from inside the appliance.
- It is recommended to insert pads or damping rubber sheets, etc. under this dehumidifier to reduce vibration, noise and possible sinking of wood floors or carpets.
- Some parts of the appliance may have been lightly greased. The first time the appliance is used, a light smoke may be detected, which will disappear after a short time.
- To eliminate any initial smell, it is recommended to operate the unit at full power for 2 hours in a well-ventilated room.
Placement and Ventilation
- Place the appliance on a horizontal, flat, stable surface away from sources of heat and possible splashing water.
- Leave a space of 50 cm between walls or other obstacles and the appliance. Do not cover or obstruct the sides of the appliance, leaving at least 50 cm space around the appliance.
- The product requires adequate ventilation in order to function properly.
Filter Installation
The dehumidifier includes an activated carbon filter and a washable plastic filter. Ensure they are correctly installed.

Operating Instructions
Power On/Off
- Extend the power cable completely before plugging it into the mains.
- Press the ON/OFF button (8) to turn the appliance on or off.
Mode Selection
Press the Mode button (7) to select between 'Auto' mode and 'Laundry' mode. The pilot light above the button indicates the selected mode.
- Auto Mode: The appliance will run until the set humidity percentage is reached. The default humidity is 50%.
- Laundry Mode: This function activates the compressor regardless of room humidity, allowing clothes to dry quicker.
Humidity Setting Function
This function is only available in 'Auto' mode.
- Press the Humidity Setting button (6) to initiate this function.
- The LED display (5) will show the current humidity percentage.
- Each press of the button increases the humidity by 5% until it reaches 80%, then it cycles back to 30%.
- Once the desired humidity is set, stop pressing the button. The appliance will run until the room's humidity is 5% lower than the chosen setting. The compressor will stop, but the fan will continue to run at the set speed.
Fan Speed
Press the Fan Speed button (3) to select between 'High' or 'Low' fan speed. The pilot light above the button indicates the selected speed.
Timer Function
- Press the Timer button (1) to initiate this function.
- The LED display (5) will show the selected time.
- Adjust the desired time by pressing the button repeatedly (1-24 hours). Each press adds one hour.
- Once the desired time is reached, stop pressing the button. After five seconds, the set time is confirmed and the pilot light above will turn on.
- To cancel the timer setup, press twice continuously after confirming the time.
Clean Function
- Press the Clean button (2) to initiate this function. The pilot light above will turn on.
- This function dries the inside of the appliance to prevent mold. This procedure lasts approximately 1 hour.
- The dehumidifier starts at high air speed and releases air continuously for 30 minutes. Then it turns to low speed for approximately 20 more minutes.
- To cancel this function, press the button again.
- Activate this function before storing the dehumidifier to prevent mold inside the appliance.
Drainage (Water Tank)
The dehumidifier features a removable water tank for collecting condensed water.
- When the water tank is full, the full tank icon (4) will start flashing and the appliance will emit a buzzing sound.
- The compressor and the fan will stop running.
- To remove the water tank, place one hand on each side of the depression areas to gently remove the water tank.
- Remove the water tank and pour the water out.
- Place the tank back into the appliance to restart the dehumidifier.
Drainage (Continuous Drainage)
For continuous operation, you can connect the provided drainage hose (inner diameter 9mm) to the drainage outlet (H).
- To install the pipe, locate the drain outlet, unscrew the drain cover and pull out the plug. Proceed to connect the 9mm drainage pipe to the outlet.
- The low end of the water pipe must be more than 10cm lower than the height of the water outlet.
- The end of the pipe cannot remain in water. It is highly recommended to install it on a place that allows the water to drain constantly.
- The water pipe must be kept smooth, otherwise the water may not be drained properly.

Maintenance
General Cleaning
- Disconnect the appliance from the mains and allow it to cool before undertaking any cleaning task.
- Clean the electrical equipment and the mains connection with a damp cloth and dry. DO NOT IMMERSE IN WATER OR ANY OTHER LIQUID.
- Clean the equipment with a damp cloth with a few drops of washing-up liquid and then dry.
- Do not use solvents, or products with an acid or base pH such as bleach, or abrasive products, for cleaning the appliance.
- Do not let water or any other liquid get into the air vents to avoid damage to the inner parts of the appliance.
- Never submerge the appliance in water or any other liquid or place it under running water.
- If the appliance is not in good condition of cleanliness, its surface may degrade and inexorably affect the duration of the appliance's useful life and could become unsafe to use.
- Then dry all parts before its assembly and storage.
Air Filter Cleaning
- Clean the air filters every 2 weeks. If the air filter is blocked with dust, its effectiveness will be reduced.
- Wash the air filters by submerging them carefully in warm water with a neutral detergent, rinse them off and let them dry completely in a shady place.
- Install the filters carefully after having them cleaned.
Troubleshooting
If you encounter any issues with your dehumidifier, refer to the tables below for common anomalies and error codes. If the problem persists, contact technical assistance.
Common Anomalies and Solutions
| Anomaly | Cause | Solution |
|---|---|---|
| The dehumidifier does not run. | Is the power plug disconnected? | Insert power plug into socket. |
| Is the water tank full or placed at incorrect position? | Drain water from the water tank, and then install the water tank again. | |
| The ambient temperature is lower than 5°C or higher than 32°C. | Normal phenomenon. The appliance does not run in these conditions for safety reasons. | |
| The dehumidification function is not effective. | Is the room temperature or humidity too low? | Under dry conditions, the dehumidification ability will reduce. |
| Air is not blown out. | Are the air outlet and inlet blocked? | Clean up the objects blocking the air outlet and inlet. |
| Is the air filter blocked? | Clean the air filter following the previously recommended method. | |
| Noise is abnormal during operation. | Is the dehumidifier placed improperly so that it is inclined or unstable? | Please place the dehumidifier in a smooth place. |
| Is the air filter blocked? | Clean the air filter following the previously recommended method. | |
| There is a "tittering" sound. | It is the sound of the refrigerant flowing, which is a normal phenomenon. | |
| Water leaks. | Connection of drainage pipe becomes loose. | Fasten drainage pipe. |
| Drainage system is blocked. | Remove obstacles and straighten out water pipe. | |
| Frosting occurs. | The ambient temperature is low, and it is in the state waiting for defrost. | It is a normal phenomenon, and the dehumidifier has the automatic defrosting function. |
Error Codes and Solutions
| Error Code | Cause | Solution |
|---|---|---|
| P1 | Anti-frost function active. | Normal phenomenon. The appliance will resume operation once defrosting is complete. |
| FL | The water tank is full. | Empty the water tank according to the instructions above. |
| LO | Room temperature is too low (<0°C). | Normal phenomenon. LO is shown on the screen. |
| HI | Room temperature is too high (>50°C). | Normal phenomenon. HI is shown on the screen. |
| E1 | The coil sensor detects an issue. | Seek a professional to check the coil sensor and related circuits. |
| E2 | The room temperature sensor detects an issue. | Seek a professional to check the room temperature sensor and related circuits. |
| CL | The appliance is drying internally. | Normal phenomenon. When the internal drying is complete, use the appliance as normal. |
Specifications
| Feature | Specification |
|---|---|
| Model Number | SDL5-10D, SDL5-12D |
| Brand Name | Shinco |
| Type | Compressor Dehumidifier |
| Capacity (pints / 24h) | 10 L / 24h |
| Dehumidification Volume | <1.1L/h |
| Water Tank Capacity (l) | 1.7L |
| Coverage Area | 161 sq. ft. (approx. 15 m²) |
| Application Area | 11 - 20 M² |
| Dimensions (L x W x H) | 25.6 x 41.5 x 20.3 cm |
| Power (W) | 200W |
| Voltage | 220 V |
| Working Temperature Range | 30%-80% |
| Fan Speed | 2 settings (High/Low) |
| Functionality | Adjustable Humidistat, Auto Restart, Automatic Bucket Full Shut-Off, Automatic Defrost, Automatic Humidistat Control, Bucket Full Indicator Light, External Drain Connect, LED Display, Removable Water Tank, Washable Air Filter |
| Certification | CB |
| Origin | Mainland China |




User Tips
- Ensure all packaging materials, especially any plastic films on filters or the unit itself, are removed before the first use to prevent operational issues.
- If the unit appears to stop working, first check the water tank. It might be full or improperly placed, triggering the automatic shut-off feature.
- Remember that this unit is a dehumidifier, designed to remove moisture from the air. It is not an air conditioner or air cooler and does not require water to be added for operation.
Warranty and Support
For any service or repair, ensure that it is performed by qualified personnel using original spare parts and accessories. Improper use or disagreement with the instructions for use can be dangerous and may void the manufacturer's warranty and liability.
For detailed warranty information, service commitments, and further support, please refer to the complete user manual available as a PDF document: View User Manual (PDF).