1. Introduction
1.1 Purpose
This manual describes the assembly, installation, operation, and troubleshooting of this unit. Please read this manual carefully before installations and operations. Keep this manual for future reference.
1.2 Scope
This manual provides safety and installation guidelines as well as information on tools and wiring.
1.3 Features
- Configurable battery charging current based on applications via LCD setting.
- Over temperature protection.
- Smart battery charger design for optimized battery performance.
- Cold start function.
1.4 Basic System Architecture
The following illustration shows the basic application for this solar charge controller.

1.5 Product Overview
The product features an LCD display, charging and fault indicators, and function buttons for user interaction. The unit includes PV input, battery input, and a ground connection.

| No. | Component |
|---|---|
| 1 | LCD display |
| 2 | Charging indicator |
| 3 | Fault indicator |
| 4 | Function buttons |
| 5 | PV input |
| 6 | Ground Connection |
| 7 | Battery input |
| 8 | Anti dust kit |
2. Safety Instructions
WARNING: This chapter contains important safety and operating instructions. Read and keep this manual for future reference.
- Before using the unit, read all instructions and cautionary markings on the unit, the batteries, and all appropriate sections of this manual.
- CAUTION - To reduce risk of injury, charge only deep-cycle lead acid type rechargeable batteries. Other types of lead acid batteries may burst, causing personal injury and damage.
- Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.
- To reduce risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
- CAUTION - Only qualified personnel can install this device with battery.
- NEVER charge a frozen battery.
- For optimum operation of this charger, please follow required spec to select appropriate cable size. It's very important to correctly operate this charger.
- Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool to spark or short circuit batteries or other electrical parts and could cause an explosion.
- Please strictly follow installation procedure when you want to disconnect DC terminals. Please refer to the INSTALLATION section of this manual for the details.
- One piece of 150A fuse is provided as over-current protection for the battery supply.
- NEVER cause DC input short circuited.
- Warning!! Only qualified service persons are able to service this device. If errors still persist after following troubleshooting table, please send this charger back to local dealer or service center for maintenance.
3. Installation
3.1 Unpacking and Inspection
Before installation, please inspect the unit. Be sure that nothing inside the package is damaged. You should have received the following items inside the package:
- The unit x 1
- User manual x 1
3.2 Preparation
Before connecting all wirings, please take off the bottom cover by removing two screws as shown below.

3.3 Mounting the Unit
Consider the following points before selecting where to install:
- Do not mount the charger on flammable construction materials.
- Mount on a solid surface.
- Install this charger at eye level in order to allow the LCD display to be read at all times.
- For proper air circulation to dissipate heat, allow a clearance of approx. 20 cm to the side and approx. 50 cm above and below the unit.
- The ambient temperature should be between 0°C and 55°C to ensure optimal operation.
- The recommended installation position is to be adhered to the wall vertically.
- Be sure to keep other objects and surfaces to guarantee sufficient heat dissipation and to have enough space for removing wires.
SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY.
Install the unit by screwing two screws. It's recommended to use M6 screws.

3.4 Battery Connection
For safety and efficient operation, use appropriate cables and ensure correct polarity.
| Model | Wire Size | Cable(mm²) | Torque value (max) |
|---|---|---|---|
| 48V/140A | 1 x 2AWG | 25 | 2 Nm |
CAUTION:
- For safety operation and regulation compliance, it's requested to install a separate DC over-current protector or disconnect device between battery and charger. Please refer to typical amperage in the table above as required fuse or breaker size.
WARNING:
- All wiring must be performed by qualified personnel.
- It's very important for system safety and efficient operation to use appropriate cable for battery connection. To reduce risk of injury, please use the proper recommended cable.
Please follow these steps to implement battery connection:
- Remove insulation sleeve 18 mm for positive and negative conductors.
- Suggest to put bootlace ferrules on the end of positive and negative wires with a proper crimping tool.
- Connect all battery packs as shown in the diagram below.
- Insert the battery wires flatly into battery connectors of the charger and make sure the bolts are tightened with a torque of 2 Nm in a clockwise direction. Ensure polarity at both the battery and the charger is correctly connected and conductors are tightly screwed into the battery terminals.
Recommended tool: #2 Pozi Screwdriver

WARNING:
- Installation must be performed with care due to high battery voltage in series.
CAUTION:
- Before making the final DC connection or closing the DC breaker/disconnector, be sure positive (+) must be connected to positive (+) and negative (-) must be connected to negative.
3.5 PV Connection
For safety and efficient operation, use appropriate cables for PV module connection.
| Model | Wire Size | Cable(mm²) | Torque value (max) |
|---|---|---|---|
| 48V/140A | 1 x 12AWG | 4 | 1.2 Nm |
CAUTION:
- Before connecting to PV modules, please install separately a DC circuit breaker between the charger and PV modules.
WARNING:
- It's very important for system safety and efficient operation to use appropriate cable for PV module connection. To reduce risk of injury, please use the proper recommended cable size.
PV Module Selection:
When selecting proper PV modules, please be sure to consider the following parameters:
- Open circuit Voltage (Voc) of PV modules must not exceed the max. PV array open circuit voltage of the charger (500Vdc).
- Open circuit Voltage (Voc) of PV modules should be higher than the min. battery voltage.
| MODEL | 48V/140A |
|---|---|
| Max. PV Array Open Circuit Voltage | 500Vdc |
| PV Array MPPT Voltage Range | 60Vdc~500Vdc |
For example, taking a 250Wp PV module, the recommended module configurations are listed below:
| Solar Panel Spec. (reference) | SOLAR INPUT (Min in serial: 6 pcs, max. in serial: 13 pcs) | Q'ty of panels | Total input power |
|---|---|---|---|
| - 250Wp - Vmp: 30.1Vdc - Imp: 8.3A - Voc: 37.7Vdc - Isc: 8.4A - Cells: 60 | 6 pcs in serial | 6 pcs | 1500W |
| 8 pcs in serial | 8 pcs | 2000W | |
| 12 pcs in serial | 12 pcs | 3000W | |
| 13 pcs in serial | 13 pcs | 3250W | |
| 8 pieces in serial and 2 sets in parallel | 16 pcs | 4000W | |
| 10 pieces in serial and 2 sets in parallel | 20 pcs | 5000W | |
| 12 pieces in serial and 2 sets in parallel | 24 pcs | 6500W |
PV Module Wire Connection:
Please follow these steps to implement PV module connection:
- Remove insulation sleeve 10 mm for positive and negative conductors.
- Suggest to put bootlace ferrules on the end of positive and negative wires with a proper crimping tool.
- Check correct polarity of wire connection from PV modules and PV input connectors. Then, connect the positive pole (+) of the connection wire to the positive pole (+) of the PV input connector. Connect the negative pole (-) of the connection wire to the negative pole (-) of the PV input connector.
Recommended tool: 4mm blade screwdriver
3.6 Final Assembly
After connecting all wirings, please put the bottom cover back by screwing two screws.
4. Operation
4.1 Operation and Display Panel
The operation and display panel is on the front of the charger. It includes two indicators, four function keys, and an LCD display, indicating the operating status and PV power information.

LED Indicator
| LED Indicator | Messages |
|---|---|
| CHG (Green) | Solid On: Battery is fully charged |
| Flashing: Battery is charging. | |
| FAULT (Red) | Solid On: Fault occurs in the charger |
| Flashing: Warning condition occurs in the charger |
Function Keys
| Function Key | Description |
|---|---|
| ESC | To exit setting mode |
| UP | To go to previous selection |
| DOWN | To go to next selection |
| ENTER | To confirm the selection in setting mode or enter setting mode |
4.2 LCD Setting
After pressing and holding the ENTER button for 3 seconds, the unit will enter setting mode. Press the "DOWN" button to select setting programs. Then, press the "ENTER" button to confirm the selection or press the "ENTER" button a second time to exit.
Setting Programs:
| No. | Description | Selectable option |
|---|---|---|
| 00 | Exit setting mode | Escape (default): 00 GOE (One-button restore setting options) 00 GOK |
| 02 | Maximum charging current | 60A (default): 02 60A Setting range is 10~140A, increment of each click is 10A. |
| 05 | Battery type | AGM: 05 AGM Flooded: 05 FLD USE (User-Defined): 05 USE (If "User-Defined" is selected, battery charge voltage can be set up in program 26 and 27.) |
| 07 | Auto restart when over temperature occurs | Restart disable (default): 07 dIS Restart enable: 07 ENA |
| 26 | Bulk charging voltage (C.V voltage) | 48V default setting: 56.4V If self-defined is selected in program 05, this program can be set up. Setting range is from 48.0V to 59.0V for 48V model. Increment of each click is 0.1V. |
| 27 | Floating charging voltage | 48V default setting: 54.0V If self-defined is selected in program 05, this program can be set up. Setting range is from 48.0V to 59.0V for 48V model. Increment of each click is 0.1V. |
| 30 | Battery equalization | Battery equalization: 30 ENA Battery equalization disable (default): 30 dIS If "Flooded" or "User-Defined" is selected in program 05, this program can be set up. |
| 31 | Battery equalization voltage | 48V default setting: 58.4V Setting range is from 48.0V to 59.0V for 48V model. Increment of each click is 0.1V. |
| 33 | Battery equalized time | 60min (default): 33 60 Setting range is from 5min to 900min. Increment of each click is 5min. |
| 34 | Battery equalized timeout | 120min (default): 34 120 Setting range is from 5min to 900min. Increment of each click is 5min. |
| 35 | Equalization interval | 30days (default): 35 30d Setting range is from 0 to 90 days. Increment of each click is 1 day. |
| 36 | Equalization activated immediately | Enable: 36 ENA Disable (default): 36 dIS If equalization function is enabled in program 30, this program can be set up. If "Enable" is selected, it activates battery equalization immediately and the LCD main page will show "E9". If "Disable" is selected, it will cancel the equalization function until the next activated equalization time arrives based on program 35 setting. At this time, "E9" will not be shown in the LCD main page. |
| 81 | Year set | 00-99 |
| 82 | Month set | 01-12 |
| 83 | Day set | 01-31 |
| 84 | Hour set | 00-24 |
| 85 | Minute set | 00-60 |
| 86 | Clean Energy | ENABLE / DISABLE |
4.3 Display
The LCD display information will be switched in turns by pressing the "UP" or "DOWN" key. The selectable information is switched in the following order: PV voltage, charging current, charging power, battery voltage, and main CPU Version.
| Selectable Information | Status | LCD Display Example |
|---|---|---|
| Version number | Stand by | U1 70 01 |
| Charging | U1 70 01 | |
| PV voltage | Stand by | INPUT 3V, BATT 44.2V |
| Charging | INPUT 389V, BATT 53.9V | |
| PV current | Stand by | INPUT 0A, BATT 44.2V |
| Charging | INPUT 2.9A, BATT 53.9V | |
| PV temperature/PV power | Stand by | TEMP 25°C, PV 0W |
| Charging | TEMP 26°C, PV 1.20kW | |
| Charge current/Battery voltage | Stand by | BATT 0A, BATT 44.2V |
| Charging | BATT 24.8A, BATT 53.9V | |
| Charge power | Stand by | BATT 23W, BATT 44.2V |
| Charging | BATT 1.34kW, BATT 53.9V | |
| Daily power generation | Stand by | 1.59kWh, DAY 889 |
| Charging | 1.59kWh, DAY 889 | |
| Monthly power generation | Stand by | 1.59kWh, MON 000 |
| Charging | 1.59kWh, MON 000 | |
| Gross generation | Stand by | 1.59kWh, EOL |
| Charging | 1.59kWh, EOL | |
| Date | Stand by | 23 11 17 |
| Charging | 23 11 17 |
4.4 Fault Reference Code
| Fault Code | Fault Event | Icon on |
|---|---|---|
| 01 | Fan is locked when charger is off. | 01 ERROR |
| 02 | Over temperature | 02 ERROR |
| 03 | Battery voltage is too high | 03 ERROR |
| 08 | Bus voltage is too high | 08 ERROR |
| 09 | Bus soft start failed | 09 ERROR |
| 51 | Over current or surge | 51 ERROR |
| 52 | Bus voltage is too low | 52 ERROR |
| 57 | Current sensor failed | 57 ERROR |
| 59 | PV voltage is over limitation | 59 ERROR |
4.5 Warning Indicator
| Warning Code | Warning Event | Audible Alarm | Icon flashing |
|---|---|---|---|
| E9 | Battery equalization | None | E9® |
| bP | Battery is not connected | None | bP |
5. Battery Equalization Description
Equalization function is added to the charge controller. It reverses the buildup of negative chemical effects like stratification, a condition where acid concentration is greater at the bottom of the battery than at the top. Equalization also helps to remove sulfate crystals that might have built up on the plates. If left unchecked, this condition, called sulfation, will reduce the overall capacity of the battery. Therefore, it's recommended to equalize the battery periodically.
5.1 How to Apply Equalization Function
You must enable the battery equalization function in monitoring LCD setting program 05 first. Then, you may apply this function in the device by either one of the following methods:
- Setting equalization interval in program 35.
- Active equalization immediately in program 36.
5.2 When to Equalize
In the float stage, when the setting equalization interval (battery equalization cycle) is reached, or equalization is active immediately, the controller will start to enter the Equalize stage.

5.3 Equalize Charging Time and Timeout
In the Equalize stage, the controller will supply power to charge the battery as much as possible until the battery voltage raises to the battery equalization voltage. The battery will remain in the Equalize stage until the setting battery equalized time is reached.

However, in the Equalize stage, when the equalized time is expired and the battery voltage doesn't rise to the battery equalization voltage point, the charge controller will extend the battery equalized time until the battery voltage achieves the battery equalization voltage. If the battery voltage is still lower than the battery equalization voltage when the battery equalized timeout setting is over, the charge controller will stop equalization and return to the float stage.
6. Clearance and Maintenance for Anti-Dust Kit
6.1 Overview
Every controller is already installed with an anti-dust kit from the factory. The controller will automatically detect this kit and activate an internal thermal sensor to adjust the internal temperature. This kit also keeps dust from your controller and increases product reliability in harsh environments.
6.2 Clearance and Maintenance Steps
- Step 1: Loosen the screw in a counterclockwise direction on the top of the controller.
- Step 2: The dustproof case can then be removed, and the air filter foam taken out.
- Step 3: Clean the air filter foam and dustproof case. After cleaning, re-assemble the dust-kit back to the controller.

NOTICE: The anti-dust kit should be cleaned from dust every one month.
7. Specifications
MPPT Solar Charging Mode
| MODEL | POW-48140A |
|---|---|
| Max. PV Array Power | 6500W |
| Nominal PV Voltage | 280Vdc |
| PV Array MPPT Voltage Range | 60Vdc~450Vdc |
| Max. PV Array Open Circuit Voltage | 500Vdc |
| Max Charging Current | 140Amp |
Charging Curve

| Parameter | Value |
|---|---|
| Dimension | 435×310×180mm |
| Weight | 6.5kg |
8. Troubleshooting
| Problem | LCD/LED/Buzzer | Explanation / Possible cause | What to do |
|---|---|---|---|
| Unit shuts down automatically during startup process. | LCD/LEDs and buzzer will be active for 3 seconds and then complete off. | The battery voltage is too low (<1.91V/Cell) | 1. Re-charge battery. 2. Replace battery. |
| No response after power on. | No indication. | 1. The battery voltage is far too low. (<1.4V/Cell) 2. Internal fuse tripped. | 1. Contact repair center for replacing the fuse. 2. Re-charge battery. 3. Replace battery. |
| Red LED is on. | Fault code 02 | Internal temperature of charger component is over 70°C. | Check whether the air flow of the unit is blocked or whether the ambient temperature is too high. |
| Battery is over-charged. | Return to repair center. | ||
| Fault code 03 | The battery voltage is too high. | Check if spec and quantity of batteries are meet requirements. | |
| Fault code 01 | Fan fault | Replace the fan. | |
| Fault code 52 | Bus voltage is too low. | Restart the unit, if the error happens again, please return to repair center. |
9. User Tips
- Wiring Clarity: While the controller has internal separation between batteries and PV, it's crucial to ensure all external wiring for battery and PV connections are clearly separated and correctly installed to prevent issues.
- Fan Noise: Be aware that the cooling fans may become noticeably louder when the charging current exceeds 40A, which is normal operation for heat dissipation.
- Initial Setup: Although the controller offers configurable settings, it's recommended to review and adjust the battery charging current and type via the LCD settings during initial setup to match your specific battery system for optimal performance and longevity.
- PDF Manual: For a detailed, printable version of the user manual, please refer to the official PDF document available at PowMr 140A 48V MPPT Solar Charge Controller User Manual (PDF).
10. Warranty and Support
For technical support, service, or warranty inquiries, please contact:
SHENZHEN HEHEJIN INDUSTRIAL CO.,LTDTel/Fax: +86755-28219903
Email: support@powmr.com
Web: www.powmr.com
Address: Henggang Street, Longgang District, Shenzhen, Guangdong, China