Models: SSR-41FDA (DC to AC) & SSR-41FDD (DC to DC)

1. Product Overview

The LCTC SSR (Solid State Relay) series, including models SSR-41FDA and SSR-41FDD, are compact, non-contact switching devices designed for various control applications. These relays offer reliable and fast switching without mechanical contacts, providing a longer lifespan and quieter operation compared to traditional electromagnetic relays. The SSR-41FDA is designed for DC control of AC loads, while the SSR-41FDD is for DC control of DC loads.

LCTC SSR Solid State Relay, showing both SSR-41FDA and SSR-41FDD models
Figure 1: LCTC Slim Relay Module (SSR-41FDA and SSR-41FDD)

2. Specifications

Below are the detailed specifications for the LCTC SSR-41FDA and SSR-41FDD models.

2.1 General Specifications

AttributeValue
TheorySolid State Relay
Contact LoadLow Power
OriginMainland China
CertificationCE
UseProtective
Protect FeatureSealed
CustomizationYes

2.2 Model-Specific Specifications

AttributeSSR-41FDA (DC to AC)SSR-41FDD (DC to DC)
Control ModeDC TO ACDC TO DC
Control Voltage3-32VDC3-32VDC
Load Voltage24-250VAC5-60VDC
Peak Current6A6A
Off State Time≤10mS≤10mS
Operating Current50mA-1A10mA-1.5A
Installation MethodInsert installationInsert installation

2.3 Product Dimensions

Product size diagram in inches
Figure 2: Product Dimensions (Unit: Inches)
  • Length: Approximately 1.1 inches (27.94 mm)
  • Width: Approximately 0.59 inches (14.99 mm)
  • Height: Approximately 0.13 inches (3.3 mm)
  • Pin Spacing (approximate): 0.14 inches, 0.19 inches, 0.03 inches
  • Pin Length (approximate): 0.64 inches

3. Setup and Wiring

Proper wiring is crucial for the safe and correct operation of the solid state relay. Always ensure power is disconnected before making any connections.

3.1 SSR-41FDD (DC Control DC Load) Wiring

This model is used to control a DC load using a DC control signal.

Wiring diagram for SSR-41FDD DC to DC relay
Figure 3: SSR-41FDD DC Control DC Wiring Diagram

Control Input:

  • Connect the positive (+) terminal of your DC control signal (3-32VDC) to pin +3 on the relay.
  • Connect the negative (-) terminal of your DC control signal to pin -4 on the relay.

Load Output:

  • Connect the positive (+) side of your DC load power source to pin 2+ on the relay.
  • Connect the negative (-) side of your DC load to pin 1- on the relay.
  • Ensure the DC load is connected in series with the relay's output terminals and the DC load power source.

Important: A load must be connected to the solid state relay for proper testing and operation.

3.2 SSR-41FDA (DC Control AC Load) Wiring

This model is used to control an AC load using a DC control signal.

Wiring diagram for SSR-41FDA DC to AC relay
Figure 4: SSR-41FDA DC Control AC Wiring Diagram

Control Input:

  • Connect the positive (+) terminal of your DC control signal (3-32VDC) to pin +3 on the relay.
  • Connect the negative (-) terminal of your DC control signal to pin -4 on the relay.

Load Output:

  • Connect one side of your AC load power source to pin 2~ on the relay.
  • Connect the other side of your AC load to pin 1~ on the relay.
  • Ensure the AC load is connected in series with the relay's output terminals and the AC load power source.

Important: A load must be connected to the solid state relay for proper testing and operation.

4. Operating Instructions

The LCTC Solid State Relays operate by receiving a control signal, which then switches the load circuit on or off. Being non-contact devices, they offer fast switching and long operational life.

  1. Power On: Ensure all wiring is correctly connected according to the diagrams in Section 3.
  2. Apply Control Signal: Apply the specified DC control voltage (3-32VDC) to the control input terminals (+3 and -4).
  3. Load Activation: When the control voltage is applied, the relay will switch on, allowing current to flow through the load circuit.
  4. Load Deactivation: When the control voltage is removed, the relay will switch off, interrupting the current to the load.
  5. Off State Time: The relay will switch off within ≤10mS after the control signal is removed.

Always operate the relay within its specified voltage and current ratings to prevent damage.

5. Maintenance

LCTC Solid State Relays are designed for long-term, maintenance-free operation due to their non-mechanical nature. However, general care can help ensure optimal performance:

  • Keep Clean: Ensure the relay and its terminals are free from dust, dirt, and moisture. Use a dry, soft cloth for cleaning if necessary.
  • Environmental Conditions: Operate the relay within its specified environmental conditions (temperature, humidity) to prevent premature failure.
  • Inspect Connections: Periodically check all wiring connections to ensure they are secure and free from corrosion.
  • Heat Dissipation: While these are low-power relays, ensure adequate ventilation around the device, especially if operating continuously at higher currents, to prevent overheating.

6. Troubleshooting

If your LCTC Solid State Relay is not functioning as expected, consider the following troubleshooting steps:

ProblemPossible CauseSolution
Relay does not switch on (load remains off)
  • No control signal or incorrect control voltage.
  • Incorrect wiring of control or load circuit.
  • Load circuit open or load faulty.
  • Relay damaged.
  • Verify control voltage (3-32VDC) is present and correctly connected to pins +3 and -4.
  • Review wiring diagrams (Figure 3 or 4) and ensure all connections are correct and secure.
  • Test the load independently to ensure it is functional. Check for breaks in the load circuit.
  • Replace the relay if all other checks pass.
Relay does not switch off (load remains on)
  • Control signal not removed or stuck high.
  • Relay damaged (e.g., output shorted).
  • Ensure the control signal is completely removed (0V) from pins +3 and -4.
  • Disconnect the control signal. If the load remains on, the relay may be damaged and needs replacement.
Relay overheats
  • Load current exceeds relay's maximum rating.
  • Insufficient ventilation.
  • Verify the load current does not exceed 6A. Consider using a relay with a higher current rating or reducing the load.
  • Ensure the relay has adequate airflow. Consider adding a heatsink if operating continuously at higher currents.

7. User Tips

  • Always use a load: When testing the relay, ensure a load is connected to the output terminals. Solid state relays require a load to properly demonstrate switching behavior.
  • Polarity for DC: For DC control and DC load models (SSR-41FDD), pay close attention to polarity (+ and -) for both the control and load circuits. Incorrect polarity can damage the relay.
  • Safety First: Always disconnect power from both the control and load circuits before performing any wiring or maintenance.

8. Warranty and Support

For any issues or questions regarding your LCTC Solid State Relay, please contact your retailer or the manufacturer's customer support. Keep your purchase receipt as proof of purchase for warranty claims.