1. Introduction

The PORTXVNSA SA5 is an advanced 2-in-1 multifunctional handheld device, combining a spectrum analyzer and a signal generator. Featuring an upgraded 4-inch IPS LCD high-definition display and intuitive knob design, it offers enhanced ease of operation and precise data reading. With a wide frequency range and a built-in 5000mAh battery, the SA5 is designed for portable and efficient signal analysis and generation tasks.

PORTXVNSA SA5 with accessories and user manual
Figure 1: PORTXVNSA SA5 device with included accessories and user manual.

2. Package Contents

Please check the contents of your package upon receipt. Depending on the kit purchased, you will receive the following:

Standard Kit:

  • Main unit (with 5000mAh battery, 4-inch display) x 1
  • USB Type-C data cable x 1
  • 30cm RG405 SMAJB2/SMAJB2 RF connecting cable x 2
  • SMA-SMA barrel connector x 1
  • Antenna with SMA connector x 1
  • Lanyard touch pad x 1
  • Touch pen x 1

Kit 2 (with 32GB MicroSD Card):

  • Main unit (with 5000mAh battery, 4-inch display) x 1
  • USB Type-C data cable x 1
  • 30cm RG405 SMAJB2/SMAJB2 RF cable x 2
  • SMA-SMA barrel connector x 1
  • Antenna with SMA connector x 1
  • Lanyard touch pad x 1
  • Touch pen x 1
  • 32GB MicroSD card (inserted into main unit) x 1

3. Key Features

  • Upgraded IPS LCD Display: 4-inch high-definition display for clear and accurate data reading.
  • Intuitive Controls: Enhanced knob design for easier operation and navigation.
  • Extended Battery Life: Built-in 5000mAh rechargeable battery provides approximately 10 hours of portable use.
  • Versatile 2-in-1 Functionality: Operates as both a Spectrum Analyzer and a Signal Generator.
  • Wide Frequency Range (Spectrum Analyzer): Covers 0.1-800MHz, with Ultra mode extending to 5.3GHz for calibrated signals and up to 12GHz for signal viewing.
  • Signal Generation Capabilities: Outputs sine waves from 0.1-800MHz, square waves up to 4.4GHz, and RF test signals up to 5.3GHz.
  • Adjustable Resolution Bandwidth: Switchable resolution bandpass filter ranging from 200Hz to 850kHz.
  • Optional Low Noise Amplifier (LNA): Features a built-in 20dB LNA for improved signal reception.
  • Advanced Display: Shows up to 450 points and supports 4 independently configurable curves for detailed analysis.
  • Data Storage: MicroSD card slot for saving measurement data, settings, and screenshots.
  • Input Attenuator: Adjustable step attenuator from 0dB to 31dB (note: not compatible for simultaneous use with LNA).
  • Self-Calibration: Built-in calibration signal generator for automatic self-test and input calibration.
  • PC Connectivity: Connects to a PC via USB for control and direct data transfer.
PORTXVNSA SA5 4-inch IPS LCD display and key features
Figure 2: Overview of SA5 features including 4-inch IPS LCD, 100KHz-5.3GHz range, 5000mAh battery, signal generator function, 32GB card support, and PC control.

4. Technical Specifications

FeatureSpecification
Model NumberSA5
Brand NamePORTXVNSA (Ponbos)
Display Size4-inch IPS LCD (3.0 - 4.9 Inches)
Battery Capacity5000mAh (rechargeable, approx. 10 hours use)
Spectrum Analyzer Frequency Range0.1-800MHz (Ultra mode up to 5.3GHz, view up to 12GHz)
Signal Generator OutputSine wave: 0.1-800MHz, Square wave: up to 4.4GHz, RF test signal: up to 5.3GHz
Resolution Bandwidth (RBW)200Hz to 850kHz (switchable)
Input Attenuator0dB to 31dB (step adjustable, not compatible with LNA)
Low Noise Amplifier (LNA)Built-in 20dB (optional)
Display PointsUp to 450 points
Configurable Curves4 independent curves
StorageMicroSD card slot (32GB card included in Kit 2)
PC ConnectivityUSB Type-C
Dimensions163.5mm x 92mm x 42mm
Package Weight545g
DIY SuppliesElectrical
OriginMainland China
CertificationCE
Average Noise Level-89dBm & Under
High-concerned chemicalNone

5. Initial Setup

5.1 Charging the Device

Before first use, fully charge the SA5 using the provided USB Type-C cable and a compatible power adapter (not included). The device features a 5000mAh battery for extended operation.

PORTXVNSA SA5 charging via USB-C
Figure 3: SA5 being charged via its USB-C port, highlighting the 5000mAh battery.

5.2 Inserting MicroSD Card (Optional)

If your kit includes a 32GB MicroSD card, it may already be inserted. If not, locate the MicroSD card slot on the side of the device and gently insert the card until it clicks into place. This card is used for storing measurement data, settings, and screenshots.

PORTXVNSA SA5 with MicroSD card slot and USB-C port
Figure 4: Side view of the SA5 showing the Type-C interface, SD card interface, and 3.5mm jack.

5.3 Connecting Antennas/RF Cables

Connect the appropriate antenna or RF cable to the 'RF' input port for spectrum analysis or to the 'CAL' port for calibration/signal generation output. Ensure connections are secure.

PORTXVNSA SA5 with antenna connected to RF port
Figure 5: SA5 with an antenna connected to the RF input, illustrating the physical connections.

5.4 Power On/Off

Locate the power switch on the device. Slide it to the 'ON' position to power on the SA5. The device will display a 'Starting...' message before showing the main measurement interface. To power off, slide the switch to the 'OFF' position.

6. Operating Instructions

The SA5 features a 4-inch IPS LCD touchscreen and a rotary knob for navigation and input. The video below demonstrates various operational aspects.

Video 1: Demonstration of PORTXVNSA SA5 features and basic operation.

6.1 Basic Navigation

  • Rotary Knob: Turn to scroll through menu options or adjust values. Press to select an option or confirm a value.
  • Touch Screen: Tap on menu items or input fields for direct interaction.

6.2 Spectrum Analyzer Mode

The SA5 functions as a spectrum analyzer to visualize signal frequencies and power levels.

PORTXVNSA SA5 2-in-1 function display
Figure 6: SA5 highlighting its 2-in-1 functionality as a spectrum analyzer and signal generator.

6.2.1 Setting Frequency Range

  1. From the main menu, select FREQUENCY.
  2. Choose START or STOP to set the desired frequency limits.
  3. Use the on-screen numeric keypad or the rotary knob to input the frequency value (e.g., 5.000GHz for START, 5.300GHz for STOP).
  4. Alternatively, set CENTER frequency and SPAN to define the displayed range.

6.2.2 Adjusting Level Settings

  1. From the main menu, select LEVEL.
  2. Adjust REF LEVEL (Reference Level) to set the top of the display range.
  3. Modify SCALE/DIV to change the vertical scale per division.
  4. Set ATTENUATE (Input Attenuator) from 0dB to 31dB. Note that the attenuator cannot be used simultaneously with the LNA.
  5. Enable or disable LNA (Low Noise Amplifier) as needed.

6.2.3 Trace Functions

  1. From the main menu, select TRACE.
  2. You can enable up to 4 traces (TRACE 1, TRACE 2, TRACE 3, TRACE 4).
  3. Options include: ENABLE (activate trace), FREEZE (pause trace update), CALC ON/OFF (enable/disable trace calculations), NORMALIZE, SUBTRACT OFF, TRACE + TRACE, SD + TRACE.
  4. Detector modes can be selected from the DISPLAY menu, including MIN HOLD, MAX HOLD, MAX GLORY, AVERAGE (e.g., AVER 4, AVER 16), and QUASI PEAK.

6.2.4 Display Options

  1. From the main menu, select DISPLAY.
  2. Options include: BIG NUMBER (display large numerical values), DRAW LINE, SWEEP TIME, SWEEP POINTS (e.g., 25, 50, 100, 200, 290, 450 points), SWEEP ACCURACY, ROTATE DISPLAY, LOCK DISPLAY.

6.2.5 Marker Functions

  1. From the main menu, select MARKER.
  2. Options include: HIDE MARKERS, MARKER OPS, SEARCH MARKER, RESET MARKERS, and enabling up to 8 markers (1 MARKER to 8 MARKERS).

6.2.6 Measurement Functions

  1. From the main menu, select MEASURE.
  2. Available measurements include: THD (Total Harmonic Distortion), CHANNEL POWER, LINEAR, and NOISE FIGURE.

6.3 Signal Generator Mode

When not in spectrum analyzer mode, the SA5 can function as a signal generator. It can output sine waves from 0.1-800MHz, square waves up to 4.4GHz, and RF test signals up to 5.3GHz. Specific controls for signal generation are typically found under a dedicated 'MODE' or 'GENERATE' menu option, allowing users to set frequency, amplitude, and waveform type.

6.4 Saving and Loading

The SA5 allows you to save and load configurations and measurement data.

  1. From the main menu, select STORAGE.
  2. Options include: LOAD STARTUP, LOAD (from internal memory or SD card), SAVE SETTINGS, SAVE FROM SD, STORE (to internal memory or SD card).
  3. When saving, you may be prompted to enter a name using an on-screen keyboard.

7. Maintenance

  • Cleaning: Use a soft, dry cloth to clean the device. Do not use abrasive cleaners or solvents.
  • Storage: Store the device in a cool, dry place away from direct sunlight and extreme temperatures.
  • Battery Care: For optimal battery life, avoid fully discharging the battery frequently. Charge the device regularly, even if not in use for extended periods.
  • Firmware Updates: Check the manufacturer's website periodically for firmware updates to ensure optimal performance and access to new features.

8. Troubleshooting

8.1 Device Not Powering On

  • Ensure the battery is charged. Connect the device to a power source using the USB Type-C cable.
  • Check the power switch is firmly in the 'ON' position.

8.2 No Signal Detected

  • Verify that the antenna or RF cable is correctly connected to the 'RF' input port.
  • Ensure the signal source is active and within the device's frequency range.
  • Check the attenuator and LNA settings. If LNA is enabled, ensure the attenuator is off.
  • Adjust the reference level and scale/div settings to properly display the signal.

8.3 Display Issues

  • If the screen is unresponsive, try restarting the device.
  • Adjust brightness settings in the 'CONFIG' menu.
  • If the display is frozen, check for any active 'FREEZE' trace functions.

8.4 PC Connection Problems

  • Ensure the USB Type-C cable is securely connected to both the SA5 and the PC.
  • Verify that the necessary drivers (if any) are installed on your PC.
  • Try a different USB port or cable.

9. User Tips

  • Optimize Battery Life: Reduce screen brightness and disable unnecessary features when operating on battery power to extend usage time.
  • Regular Calibration: Utilize the built-in calibration signal generator periodically to maintain measurement accuracy.
  • Experiment with Traces: Use multiple traces and trace math functions to compare signals, analyze changes over time, or subtract noise for clearer readings.
  • Utilize Storage: Save frequently used settings as presets and capture screenshots of important measurements for later review or documentation.
  • PC Integration: For complex analysis or long-term data logging, connect the SA5 to a PC to leverage larger display capabilities and software features.