PowMr POW-LVM2.4K-24V

Contents

PowMr 2400W Hybrid Solar Inverter User Manual

Model: POW-LVM2.4K-24V

1. Introduction

This manual describes the assembly, installation, operation, and troubleshooting of the PowMr 2400W Hybrid Solar Inverter. Please read this manual carefully before installation and operation. Keep this manual for future reference.

This multi-function inverter/charger combines the functions of an inverter, solar charger, and battery charger to provide uninterruptible power support in a portable size. Its comprehensive LCD display offers user-configurable and easy-to-access button operation for settings such as battery charging current, AC/solar charger priority, and acceptable input voltage based on different applications.

1.1 Key Features

  • Pure sine wave inverter
  • Configurable input voltage range for home appliances and personal computers via LCD setting
  • Configurable battery charging current based on applications via LCD setting
  • Configurable AC/Solar Charger priority via LCD setting
  • Compatible with mains voltage or generator power
  • Auto restart while AC is recovering
  • Overload/Over temperature/short circuit protection
  • Smart battery charger design for optimized battery performance
  • Cold start function

1.2 System Architecture

The inverter/charger can be integrated into a hybrid power system. It can power various appliances in home or office environments, including motor-type appliances like tube lights, fans, refrigerators, and air conditioners.

Diagram of Hybrid Power System showing connections between solar panels, generator/utility, inverter, battery, and home appliances.
Figure 1: Hybrid Power System Diagram. This diagram illustrates how solar power, a generator or utility, and external battery packs connect to the inverter to supply power to home appliances.
Inverter with dimensions and display details
Figure 2: Inverter dimensions and display overview. The image shows the inverter's physical size (13.97in height, 10.7in width, 3.9in depth) and its LCD display indicating input/output, battery, and load status. Key specifications like 2400W rated output, 50A max solar charge current, 50AMP 24VDC charging current, and 80VDC max PV array open circuit voltage are highlighted.
Inverter charging and output modes
Figure 3: Charging and Output Modes. This diagram illustrates four charging modes (Solar First, Utility First, Solar and Utility, Only Solar) and three load output working modes (Utility First, Solar First, SBU First).
Inverter battery compatibility
Figure 4: Multiple Battery Compatibility. The inverter is compatible with Flooded Batteries, AGM Batteries, Gel Batteries, and Sealed Lead Acid Batteries.

2. Safety Instructions

WARNING: This chapter contains important safety and operating instructions. Read and keep this manual for future reference.

  1. Before using the unit, read all instructions and cautionary markings on the unit, the batteries, and all appropriate sections of this manual.
  2. CAUTION: To reduce risk of injury, charge only deep-cycle lead-acid type rechargeable batteries. Other types of batteries may burst, causing personal injury and damage.
  3. Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.
  4. To reduce risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
  5. CAUTION: Only qualified personnel can install this device with battery.
  6. NEVER charge a frozen battery.
  7. For optimum operation of this inverter/charger, please follow required specifications to select appropriate cable size. It's very important to correctly operate this inverter/charger.
  8. Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool to spark or short circuit batteries or other electrical parts and could cause an explosion.
  9. Please strictly follow installation procedure when you want to disconnect AC or DC terminals. Please refer to the INSTALLATION section of this manual for the details.
  10. Fuses (6 pieces of 40A, 32VDC for 2.4KW) are provided as over-current protection for the battery supply.
  11. GROUNDING INSTRUCTIONS: This inverter/charger should be connected to a permanent grounded wiring system. Be sure to comply with local requirements and regulations to install this inverter.
  12. NEVER cause AC output and DC input short-circuited. Do NOT connect to the mains when DC input short circuits.
  13. Warning!! Only qualified service persons are able to service this device. If errors still persist after following troubleshooting table, please send this inverter/charger back to local dealer or service center for maintenance.

3. Setup and Installation

3.1 Unpacking and Inspection

Before installation, please inspect the unit. Ensure nothing inside the package is damaged. The package should contain:

  • The inverter unit x 1
  • User manual x 1
  • Communication cable x 1
  • Software CD x 1

For a visual guide on unpacking, refer to the product video:

Video: Unboxing the PowMr Hybrid Solar Inverter. This video demonstrates the contents of the package, including the inverter, user manual, and communication cable.

3.2 Preparation

Before connecting all wirings, remove the bottom cover by unscrewing two screws.

3.3 Mounting the Unit

Consider the following points when selecting an installation location:

  • Do not mount the inverter on flammable construction materials.
  • Mount on a solid surface.
  • Install this inverter at eye level to allow the LCD display to be read at all times.
  • For proper air circulation to dissipate heat, allow a clearance of approximately 20 cm to the side and approximately 50 cm above and below the unit.
  • The ambient temperature should be between 0°C and 55°C to ensure optimal operation.
  • The recommended installation position is to be adhered to the wall vertically.
  • Ensure other objects and surfaces are kept clear as shown in the diagram to guarantee sufficient heat dissipation and enough space for removing wires.

SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY.

Inverter mounting diagram with dimensions
Figure 5: Inverter Mounting Diagram. This image shows the recommended clearances for installation: 50cm above and below, and 20cm on the sides for proper ventilation.

Install the unit by screwing three M4 or M5 screws into the designated mounting points.

3.4 Wiring

WARNING: All wiring must be performed by qualified personnel.

3.4.1 Battery Connection

CAUTION: For safety and regulation compliance, install a separate DC over-current protector or disconnect device between the battery and inverter. It is very important to use appropriate cable for battery connection to reduce risk of injury.

The 2.4KW model supports a 24VDC system. It is suggested to connect at least a 100Ah capacity battery for the 2.4KW model.

  1. Assemble battery ring terminals based on the recommended battery cable and terminal size.
  2. Connect all battery packs as shown in the diagram.
  3. Insert the ring terminal of the battery cable flatly into the battery connector of the inverter and ensure the bolts are tightened with a torque of 2-3 Nm. Ensure polarity at both the battery and the inverter/charger is correctly connected, and ring terminals are tightly screwed to the battery terminals.

WARNING: Shock Hazard. Installation must be performed with care due to high battery voltage in series.

CAUTION:

  • Do not place anything between the flat part of the inverter terminal and the ring terminal. Otherwise, overheating may occur.
  • Do not apply anti-oxidant substance on the terminals before terminals are connected tightly.
  • Before making the final DC connection or closing the DC breaker/disconnector, ensure positive (+) is connected to positive (+) and negative (-) is connected to negative (-).
Recommended Battery Cable and Terminal Size
ModelTypical AmperageBattery CapacityWire SizeCable (mm²)Ring Terminal D(mm)Ring Terminal L(mm)Torque Value
2.4KW100A100Ah1*4 AWG226.433.22~3Nm
2.4KW100A200Ah2*8 AWG146.429.2

3.4.2 AC Input/Output Connection

WARNING: All wiring must be performed by qualified personnel. It's very important for system safety and efficient operation to use appropriate cable for AC input connection. To reduce risk of injury, please use the proper recommended cable size.

CAUTION:

  • Before connecting to AC input power source, install a separate AC breaker between the inverter and AC input power source. This ensures the inverter can be securely disconnected during maintenance and fully protected from overcurrent of AC input. The recommended specification for the AC breaker is 45A for 2.4KW.
  • There are two terminal blocks with "IN" and "OUT" markings. Do NOT mis-connect input and output connectors.
  1. Before making AC input/output connection, open the DC protector or disconnector first.
  2. Remove insulation sleeve 10mm for six conductors. Shorten phase L and neutral conductor N by 3mm.
  3. Insert AC input wires according to polarities indicated on the terminal block and tighten the terminal screws. Ensure to connect the PE protective conductor (Ground, yellow-green) first.
  4. Then, insert AC output wires according to polarities indicated on the terminal block and tighten the terminal screws. Ensure to connect the PE protective conductor (Ground, yellow-green) first.
  5. Make sure the wires are securely connected.
AC wiring diagram for inverter
Figure 6: AC Input/Output Wiring Diagram. This diagram shows the correct connection points for AC input and output, including the circuit breaker and terminal block.

CAUTION:

  • Ensure AC wires are connected with correct polarity. If L and N wires are connected reversely, it may cause utility short-circuiting when these inverters are operated in parallel.
  • Appliances such as air conditioners require at least 2-3 minutes to restart to balance refrigerant gas. If a power shortage occurs and recovers quickly, it can damage connected appliances. Check if your air conditioner has a time-delay function before installation. Otherwise, the inverter/charger may trigger an overload fault and cut off output to protect your appliance, but internal damage may still occur.
AC Input/Output Connection Specifications
ModelGaugeTorque Value
2.4KW10 AWG1.2~1.6 Nm

3.4.3 PV Connection (for models with solar charger)

WARNING: All wiring must be performed by qualified personnel. It's very important for system safety and efficient operation to use appropriate cable for PV module connection. To reduce risk of injury, please use the proper recommended cable size.

CAUTION: Before connecting to PV modules, install a separate DC circuit breaker between the inverter and PV modules.

When selecting proper PV modules, consider the following requirements:

  1. Open circuit Voltage (Voc) of PV modules must not exceed the maximum PV array open circuit voltage of the inverter (80Vdc).
  2. Maximum Power Voltage (Vmpp) of PV modules should be close to the best Vmp of the inverter or within the Vmp range (30V~32V) for best performance. If one PV module cannot meet this requirement, use several PV modules in series connection.
PV Module Selection Guide (2.4KW Inverter)
ModelTypical AmperageGaugeTorque Value
2.4KW50A8 AWG1.4~1.6 Nm
Inverter Model Specifications for Solar Charger
ParameterPOW-LVM2.4K-24V
Charging Current50Amp
System DC Voltage24Vdc
Operating Voltage Range30~32Vdc
Max. PV Array Open Circuit Voltage80Vdc
PV Module Vmp Range
ModelBest VmpVmp Range
2.4KW30Vdc30V~32V

Follow these steps to implement PV module connection:

  1. Remove insulation sleeve 10 mm for positive and negative conductors.
  2. Check correct polarity of connection cable from PV modules and PV input connectors. Connect positive pole (+) of connection cable to positive pole (+) of PV input connector. Connect negative pole (-) of connection cable to negative pole (-) of PV input connector.
  3. Make sure the wires are securely connected.
PV wiring diagram for inverter
Figure 7: PV Connection Diagram. This diagram illustrates how to connect PV modules to the inverter, ensuring correct polarity for positive and negative terminals.

3.5 Final Assembly

After connecting all wirings, replace the bottom cover by screwing the two screws back into place.

4. Operation

4.1 Power ON/OFF

Once the unit has been properly installed and the batteries are connected, simply press the On/Off switch (located on the bottom of the case) to turn on the unit.

4.2 Operation and Display Panel

The operation and display panel is on the front of the inverter. It includes three indicators, four function keys, and an LCD display, showing operating status and input/output power information.

Inverter front panel with LCD display and buttons
Figure 8: Product Overview with Labeled Components. This image highlights the LCD display, status indicator, charging indicator, fault indicator, function buttons, power on/off switch, AC input/output, PV input, battery input, circuit breaker, RS232 communication port, and dry contact.
Function Keys Description
Function KeyDescription
ESCTo exit setting mode
UPTo go to previous selection
DOWNTo go to next selection
ENTERTo confirm the selection in setting mode or enter setting mode

4.3 LCD Display Icons and Settings

The LCD display provides various information about the inverter's status and operation. The information can be cycled through using the "UP" or "DOWN" keys.

4.3.1 LED Indicators

LED Indicator Messages
LED IndicatorColorStateMessage
AC/INVGreenSolid OnOutput is powered by utility in Line mode.
FlashingOutput is powered by battery or PV in battery mode.
CHGGreenSolid OnBattery is fully charged.
FlashingBattery is charging.
FAULTRedSolid OnFault occurs in the inverter.
FlashingWarning condition occurs in the inverter.

4.3.2 LCD Display Icons

The LCD screen displays various icons to represent the inverter's status, input sources, and operational modes.

  • Input Source Information:
    • AC Icon: Indicates the AC input.
    • PV Icon: Indicates the PV input.
    • INPUT/BATT: Indicates input voltage, input frequency, PV voltage, battery voltage, and charger current.
  • Configuration Program and Fault Information:
    • 88 Icon: Indicates the setting programs.
    • 8.8▲ Icon: Indicates warning and fault codes. Flashing indicates a warning code, solid indicates a fault code.
  • Output Information:
    • OUTPUT/BATT/LOAD: Indicates output voltage, output frequency, load percentage, load in VA, load in Watt, and discharging current.
  • Battery Information:
    • CHARGING Icon: Indicates battery level (0-24%, 25-49%, 50-74%, 75-100%) in battery mode and charging status in line mode.
  • Load Information:
    • OVER LOAD Icon: Indicates overload.
    • Load Level Icons: Indicates load level by 0-24%, 25-50%, 50-74%, and 75-100%.
  • Mode Operation Information:
    • Mains Icon: Indicates unit connects to the mains.
    • PV Panel Icon: Indicates unit connects to the PV panel.
    • BYPASS Icon: Indicates load is supplied by utility power.
    • Utility Charger Icon: Indicates the utility charger circuit is working.
    • DC/AC Inverter Icon: Indicates the DC/AC inverter circuit is working.
  • Mute Operation:
    • Mute Icon: Indicates unit alarm is disabled.

4.4 LCD Settings

After pressing and holding the ENTER button for 3 seconds, the unit will enter setting mode. Use the "UP" or "DOWN" buttons to select setting programs. Press "ENTER" to confirm the selection or "ESC" to exit.

Some key settings include:

  • Program 00: Exit setting mode.
  • Program 01: Output source priority. Configures load power source priority (Solar first, Utility first, SBU priority).
  • Program 02: Maximum charging current. Configures total charging current for solar and utility chargers (Max. charging current = utility charging current + solar charging current). Setting range: 20-80A, increment of 10A.
  • Program 03: AC input voltage range. Selects acceptable AC input voltage range (Appliances: 65-140VAC, UPS: 95-140VAC).
  • Program 04: Power saving mode enable/disable.
  • Program 05: Battery type. Selects battery type (AGM, Flooded, User-Defined).
  • Program 06: Auto restart when overload occurs.
  • Program 07: Auto restart when over temperature occurs.
  • Program 09: Output frequency. (50Hz/60Hz).
  • Program 11: Maximum utility charging current.
  • Program 12: Setting voltage point back to utility source. (22.0-25.5V, increment 0.5V).
  • Program 13: Setting voltage point back to battery mode. (24-29V, increment 0.5V).
  • Program 16: Charger source priority. Configures charger source priority (Solar first, Utility first, Solar and Utility, Only Solar).
  • Program 18: Alarm control. (Alarm on/off).
  • Program 19: Auto return to default display screen. (Return to default, Stay at latest screen).
  • Program 20: Backlight control. (Backlight on/off).
  • Program 22: Beeps while primary source is interrupted. (Alarm on/off).
  • Program 23: Overload bypass. (Bypass disable/enable).
  • Program 25: Record Fault code. (Record enable/disable).
  • Program 26: Bulk charging voltage (C.V voltage). Setting range: 24.0V to 29.2V, increment 0.1V.
  • Program 27: Floating charging voltage. Setting range: 24.0V to 29.2V, increment 0.1V.
  • Program 29: Low DC cut-off voltage. Setting range: 20.0V to 24.0V, increment 0.1V.
  • Program 30: Battery equalization. (Enable/Disable).
  • Program 31: Battery equalization voltage. Setting range: 25.0V to 30V, increment 0.1V.
  • Program 33: Battery equalized time. Setting range: 5min to 900min, increment 5min.
  • Program 34: Battery equalized timeout. Setting range: 5min to 900min, increment 5min.
  • Program 35: Equalization interval. Setting range: 0 to 90 days, increment 1 day.
  • Program 36: Equalization activated immediately. (Enable/Disable).

4.5 Operating Mode Description

The inverter operates in various modes, each with specific charging and power supply behaviors:

  • Standby Mode / Power Saving Mode: The inverter is not turned on yet but can charge the battery without AC output. If power saving mode is enabled, the inverter output will be off when the connected load is very low or not detected.
  • Fault Mode: Errors caused by internal circuit issues or external reasons (e.g., over temperature, output short circuit). In this mode, PV energy and utility can still charge batteries.
  • Line Mode: The unit provides output power from the mains and charges the battery.
  • Battery Mode: The unit provides output power from the battery and PV power.

4.6 Battery Equalization

The equalization function helps reverse the buildup of negative chemical effects like stratification and removes sulfate crystals from battery plates, which can reduce battery capacity. It is recommended to equalize the battery periodically.

4.6.1 How to Apply Equalization Function

Enable the battery equalization function in monitoring LCD setting program 30. Then, apply this function by either:

  • Setting the equalization interval in program 35.
  • Activating equalization immediately in program 36.

4.6.2 When to Equalize

In the float stage, when the set equalization interval is reached, or equalization is activated immediately, the controller will enter the Equalize stage.

In the Equalize stage, the controller supplies power to charge the battery until its voltage reaches the battery equalization voltage. Constant-voltage regulation is then applied to maintain the battery voltage. The battery remains in the Equalize stage until the set battery equalized time is reached.

If the battery equalized time expires and the battery voltage does not reach the equalization voltage point, the charge controller extends the battery equalized time until the battery voltage achieves the equalization voltage. If the battery voltage is still lower than the equalization voltage when the battery equalized timeout setting is over, the charge controller stops equalization and returns to the float stage.

5. Maintenance

Regular maintenance ensures the longevity and optimal performance of your PowMr Hybrid Solar Inverter. Always disconnect all power sources (AC, DC, and PV) before performing any maintenance.

  • Cleaning: Periodically clean the exterior of the inverter with a dry, soft cloth. Ensure ventilation openings are free from dust and debris to maintain proper airflow and prevent overheating.
  • Connections: Regularly check all wiring connections (battery, AC input/output, PV input) for tightness and signs of corrosion. Loose connections can lead to poor performance or safety hazards.
  • Battery Health: Monitor battery voltage and performance. Ensure batteries are not overcharged or deeply discharged. Follow battery manufacturer guidelines for maintenance.
  • Environment: Ensure the installation environment remains within the specified operating temperature range (0°C to 55°C) and is free from excessive moisture or dust.
  • Firmware Updates: Check the official PowMr website periodically for any available firmware updates that may improve performance or address known issues.

6. Troubleshooting

This section provides information on common issues, fault codes, and warning indicators to help diagnose and resolve problems with your inverter.

6.1 Fault Reference Code

If a fault occurs, the inverter's red FAULT LED will be solid on, and an error code will be displayed on the LCD. Refer to the table below for fault descriptions and corrective actions.

Fault Reference Codes
Fault CodeFault EventWhat to do
01Fan is locked when inverter is off.Replace the fan.
02Over temperature.Check whether the air flow of the unit is blocked or whether the ambient temperature is too high.
03Battery voltage is too high.Check if specifications and quantity of batteries meet requirements. Return to repair center if issue persists.
04Battery voltage is too low.Return to repair center.
05Output short circuited or over temperature is detected by internal converter components.Check if wiring is connected well and remove abnormal load.
06Output voltage is abnormal.Return to repair center.
07Overload time out.Reduce the connected load by switching off some equipment.
08Bus voltage is too high.Reduce the connected load. Return to repair center.
09Bus soft start failed.Return to repair center.
11Main relay failed.Return to repair center.

6.2 Warning Indicator

If a warning condition occurs, the red FAULT LED will flash, and an audible alarm may sound. Refer to the table below for warning events and their indications.

Warning Indicators
Warning CodeWarning EventAudible Alarm
01Fan is locked when inverter is on.Beep three times every second.
03Battery is over-charged.Beep once every second.
04Low battery.Beep once every second.
07Overload.Beep once every 0.5 second.
10Output power derating.Beep twice every 3 seconds.

6.3 General Troubleshooting

This table provides solutions for common operational issues not covered by specific fault or warning codes.

General Troubleshooting Table
ProblemLCD/LED/BuzzerExplanation / Possible CauseWhat to do
Unit shuts down automatically during startup process.LCD/LEDs and buzzer will be active for 3 seconds and then complete off.The battery voltage is too low (<1.91V/Cell).1. Re-charge battery. 2. Replace battery.
No response after power on.No indication.1. The battery voltage is far too low (<1.4V/Cell). 2. Battery polarity is connected reversed.1. Check if batteries and the wiring are connected well. 2. Re-charge battery. 3. Replace battery.
Input voltage is displayed as 0 on the LCD and green LED is flashing.Input protector is tripped.Check if AC breaker is tripped and AC wiring is connected well.
Mains exist but the unit works in battery mode.Green LED is flashing.Insufficient quality of AC power (Shore or Generator).1. Check if AC wires are too thin and/or too long. 2. Check if generator (if applied) is working well or if input voltage range setting is correct (UPS → Appliance).
Green LED is flashing.Set "Solar First" as the priority of output source.Change output source priority to Utility first.
When the unit is turned on, internal relay is switched on and off repeatedly.LCD display and LEDs are flashing.Battery is disconnected.Check if battery wires are connected well.

7. Specifications

Detailed technical specifications for the PowMr 2400W Hybrid Solar Inverter are provided below.

7.1 Table 1 Line Mode Specifications

Line Mode Specifications
ParameterPOW-LVM2.4K-24V
Input Voltage WaveformSinusoidal (utility or generator)
Nominal Input Voltage120Vac
Low Loss Voltage95Vac±7V(UPS); 65Vac±7V (Appliances)
Low Loss Return Voltage100Vac±7V(UPS); 70Vac±7V (Appliances)
High Loss Voltage140Vac±7V
High Loss Return Voltage135Vac±7V
Max AC Input Voltage150Vac
Nominal Input Frequency50Hz/60Hz (Auto detection)
Low Loss Frequency40±1Hz
Low Loss Return Frequency42±1Hz
High Loss Frequency65±1Hz
High Loss Return Frequency63±1Hz
Output Short Circuit ProtectionCircuit Breaker
Efficiency (Line Mode)>95% (Rated R load, battery full charged)
Transfer Time10ms typical (UPS); 20ms typical (Appliances)

Output power derating: When AC input voltage drops to 95V, the output power will be derated.

7.2 Table 2 Inverter Mode Specifications

Inverter Mode Specifications
ParameterPOW-LVM2.4K-24V
Rated Output Power3KVA/2.4KW
Output Voltage WaveformPure Sine Wave
Output Voltage Regulation120Vac±5%
Output Frequency60Hz
Peak Efficiency90%
Overload Protection5s@≥150% load; 10s@110%~150% load
Surge Capacity2 * rated power for 5 seconds
Nominal DC Input Voltage24Vdc
Cold Start Voltage23.0Vdc
Low DC Warning Voltage22.0 Vdc (@load < 20%); 21.4 Vdc (@20% ≤ load < 50%); 20.2 Vdc (@load ≥ 50%)
Low DC Warning Return Voltage23.0 Vdc (@load < 20%); 22.4 Vdc (@20% ≤ load < 50%); 21.2 Vdc (@load ≥ 50%)
Low DC Cut-off Voltage21.0 Vdc (@load < 20%); 20.4 Vdc (@20% ≤ load < 50%); 19.2 Vdc (@load ≥ 50%)
High DC Recovery Voltage29 Vdc
High DC Cut-off Voltage31 Vdc
No Load Power Consumption<20W
Saving Mode Power Consumption<10W

7.3 Table 3 Charge Mode Specifications

Charge Mode Specifications
ParameterPOW-LVM2.4K-24V
Charging Algorithm3-Step
Utility Charging Mode
AC Charging Current20/30Amp (@VI/p=120Vac)
Bulk (Flooded Battery)29.2
Charging (AGM / Gel Battery)28.2
Floating Charging Voltage27Vdc
Solar Charging Mode
Max. PV Array Power1200W
Charging Current (PWM)50Amp
System DC Voltage24Vdc
Operating Voltage Range30~32Vdc
Max. PV Array Open Circuit Voltage80Vdc
Standby Power Consumption2W
DC Voltage Accuracy+/-0.3%
Joint Utility and Solar Charging
Max Charging Current80Amp
Default Charging Current50Amp

7.4 Table 4 General Specifications

General Specifications
ParameterPOW-LVM2.4K-24V
Safety CertificationCE
Operating Temperature Range0°C to 55°C
Storage temperature-15°C~60°C
Dimension (D*W*H)100x272x355 mm
Net Weight6.9 kg

7.5 Appendix: Approximate Back-up Time Table

The backup time depends on the quality, age, and type of battery. Specifications of batteries may vary depending on different manufacturers.

Approximate Back-up Time (2.4KW Model)
Load (VA)Backup Time @24Vdc 100Ah (min)Backup Time @24Vdc 200Ah (min)
3004491100
600222525
900124303
120095227
150068164
180056126
210048108
24003594
27003174
30002867

8. Warranty and Support

The PowMr 2400W Hybrid Solar Inverter comes with a 12-month warranty. For detailed warranty terms, conditions, and support information, please refer to the official user manual PDF available for download.

You can access the full user manual (PDF) for comprehensive details on installation, operation, and warranty information:

View User Manual (PDF)

For technical assistance or service, please contact your local dealer or an authorized service center.

9. User Tips

Based on general best practices for solar inverters, here are some tips for optimizing your PowMr Hybrid Solar Inverter's performance and longevity:

  • Battery Matching: Always ensure your battery bank voltage and capacity are correctly matched to the inverter's requirements (24V system, minimum 100Ah recommended).
  • Ventilation is Key: Proper airflow around the inverter is crucial to prevent overheating. Ensure the recommended clearances (50cm top/bottom, 20cm sides) are maintained.
  • Regular Monitoring: Periodically check the LCD display for any warning or fault codes. Early detection can prevent minor issues from becoming major problems.
  • Cable Sizing: Use appropriately sized cables for all connections (battery, AC, PV) as specified in the manual to minimize power loss and ensure safety.
  • Grounding: Always ensure the inverter is properly grounded to a permanent grounded wiring system as per local regulations.
  • Load Management: Avoid consistently running the inverter at its maximum capacity. Distribute loads to prevent frequent overloads, which can reduce the inverter's lifespan.