1. Introduction
The ElecDemo Acs758 is a high-precision Hall effect DC current detection module designed for measuring direct current in the range of 0-50A. It provides both an analog voltage output (0-5V) and serial port communication for direct current value reading, making it suitable for various applications including PLC data acquisition systems. The module features an on-board potentiometer for adjustable threshold control and relay activation.
2. Features
- Analog Voltage Output: Provides a 0-5V analog signal proportional to the detected current.
- Serial Port Communication: Allows direct reading of 0-50A current values via a serial assistant when connected with a USB to TTL module.
- Adjustable Threshold: Equipped with an on-board potentiometer for setting current thresholds.
- Relay Control: Integrated relay can be controlled based on the set current threshold.
- Serial Port Threshold Control: Thresholds and relay operation can also be configured via serial commands for enhanced convenience.
- Easy Installation: Designed with mounting holes for straightforward integration into projects.
3. Specifications
| Parameter | Value |
|---|---|
| Working Voltage | 7V ~ 12V DC |
| Detection Current Range | DC 0-50A |
| Measurement Error | ± 0.1A |
| Output Signal | 0-5V Analog Voltage, Serial Port Data |
| Dimensions (L x W x H) | 80mm x 30mm x 20mm |
| Module Type | PLC Data Acquisition Module |
4. Setup
Before connecting, ensure all power sources are disconnected. Refer to the diagram below for component identification and connection points.

- Power Supply Connection: Connect a DC power source (7-12V) to the VCC Power Supply and GND pins.
- Current Input/Output: Connect the DC circuit whose current you wish to measure to the 'Current Input' and 'Current Output' terminals. Ensure correct polarity.
- Analog Output: The '0-5V analog voltage output' pin provides an analog signal proportional to the measured current. This can be connected to an ADC (Analog-to-Digital Converter) for reading.
- Serial Communication (Optional): For direct digital current readings, connect the module's GND, RX, and TX pins to a USB to TTL module. Then, connect the USB to TTL module to your computer.
- Relay Connections: The module includes a relay with 'Always open', 'Public side', and 'Normally closed end' terminals. These can be wired into a control circuit based on your application's requirements.
- Threshold Adjustment: The 'ADJ-potentiometer' allows for manual adjustment of the current threshold that triggers the relay and the 'Threshold warning light'.
5. Operating Instructions
- Power On: Apply the specified 7-12V DC power to the module. The power indicator LED should illuminate.
- Current Measurement: As current flows through the 'Current Input' and 'Current Output' terminals, the module will detect its value.
- Reading Analog Output: Monitor the '0-5V analog voltage output' pin with an appropriate measurement device (e.g., microcontroller ADC, multimeter) to obtain the current reading.
- Reading Serial Output: If connected via a USB to TTL module to a computer, open a serial terminal program (e.g., PuTTY, Arduino Serial Monitor) with the correct baud rate (refer to PDF schematic for details) to directly read the current values (0-50A).
- Adjusting Threshold:
- Potentiometer: Turn the 'ADJ-potentiometer' to set the desired current threshold. The 'Threshold warning light' will indicate when the current crosses this threshold.
- Serial Port: Use specific serial commands (detailed in the PDF schematic) to set the threshold and control the relay programmatically.
- Relay Operation: The relay will activate or deactivate based on the comparison of the measured current with the set threshold. The 'Always open', 'Public side', and 'Normally closed end' terminals will switch accordingly.

6. User Tips
- Polarity: Always double-check the polarity of the current input and power supply connections to prevent damage to the module.
- Calibration: For applications requiring high precision, it is recommended to calibrate the sensor using a known current source and fine-tune the potentiometer or serial settings.
- Stable Power: Use a stable and regulated power supply within the 7-12V range to ensure accurate and consistent readings.
- Serial Assistant: When using serial communication, ensure the correct baud rate and COM port are selected in your serial terminal software.
7. Troubleshooting
- No Power Indicator:
- Check power supply voltage (7-12V) and connections.
- Ensure correct polarity of the power supply.
- No Current Reading (Analog/Serial):
- Verify that current is actually flowing through the 'Current Input' and 'Current Output' terminals.
- Check all wiring connections for looseness or errors.
- For serial output, ensure the USB to TTL module is correctly connected and the serial port settings (baud rate, COM port) are correct.
- Inaccurate Current Reading:
- Ensure the measured current is within the 0-50A range.
- Check for external electromagnetic interference.
- Recalibrate the module using the ADJ-potentiometer or serial commands.
- Relay Not Triggering:
- Verify the current threshold setting using the potentiometer or serial interface.
- Ensure the measured current is crossing the set threshold.
- Check the relay's wiring and the load connected to it.
8. Maintenance
- Cleaning: Keep the module clean and free from dust and debris. Use a soft, dry cloth for cleaning.
- Environmental Conditions: Avoid exposing the module to extreme temperatures, high humidity, or corrosive environments.
- Connection Integrity: Periodically inspect all wiring connections to ensure they are secure and free from corrosion.
9. Warranty and Support
This ElecDemo module comes with a manufacturer's limited warranty of 3 months on defective items, excluding items damaged or misused after receipt. The displayed images are for reference, and the actual product may vary slightly due to production batches.
For technical support, questions, or to request the PDF schematic, please contact ElecDemo customer service after purchase. They will provide the necessary information and assistance.