1. Introduction
The MASTECH MS2138 and MS2138R are professional AC/DC digital clamp meters designed for accurate and reliable electrical measurements. These meters are suitable for a wide range of applications, including testing and maintenance in universities, vocational colleges, refining, communication, manufacturing, petroleum, national defense, electricity, power supply systems, and circuit power equipment. They feature a 4000-count display, auto and manual ranging, and various measurement functions for current, voltage, resistance, capacitance, and frequency.
2. Safety Information
Please read and understand all safety information before operating this device. Failure to follow these instructions may result in electric shock, fire, or damage to the meter or the equipment under test.
- Always adhere to local and national safety codes.
- Do not use the meter if it appears damaged or if the test leads are damaged.
- Ensure the rotary switch is in the correct position for the desired measurement before connecting the test leads.
- Do not apply more than the rated voltage, as marked on the meter, between terminals or between any terminal and ground.
- Use caution when working with voltages above 60V DC or 30V AC RMS, as these pose a shock hazard.
- When measuring current with the clamp, ensure only one wire in the circuit is clamped.
- The device has a Safety Rating of CAT III 600V.
3. Package Contents
Verify that all items are present and undamaged:
- MASTECH MS2138 or MS2138R Digital Clamp Meter
- Test leads (one red, one black)
- Carry bag
- User's manual
- *Note: 3x1.5V AAA batteries are required but not included.*

4. Key Features
- Display: 4000 counts
- Jaw Opening: Φ40mm / 1.6"
- Ranging: Auto & Manual
- Auto Power Off function
- Diode Open Voltage: 2.8V
- Continuity Buzzer: Less than 50 ±20Ω
- Relative Measurement mode
- Data Hold function
- Low Battery Display indicator
- Display Backlight for low-light conditions
- Work Light for illuminating the measurement area
- Bar Graph display
- True Root Mean Square (True RMS) for MS2138R model
- DCA automatic zero return key (MS2138R only)

5. Technical Specifications
Measurement Ranges and Accuracy
| Specifications | Range | Resolution | Accuracy |
|---|---|---|---|
| DC Voltage | 400mV | 0.1mV | ±(1.0%+2) |
| 4V/40V/400V | 0.001V/0.01V/0.1V | ±(0.7%+2) | |
| 600V | 1V | ±(0.8%+2) | |
| AC Voltage | 400mV/4V/40V/400V | 0.0001V/0.001V/0.01V/0.1V | ±(0.8%+3) |
| 600V | 1V | ±(1.0%+4) | |
| DC Current | 40A/400A/1000A | 0.01A/0.1A/1A | ±(3.0%+6) |
| AC Current | 40A/400A/1000A | 0.01A/0.1A/1A | ±(2.5%+6) |
| Resistance | 400Ω/4kΩ/40kΩ/400kΩ | 0.1Ω/0.001kΩ/0.01kΩ/0.1kΩ | ±(0.8%+3) |
| 4MΩ/40MΩ | 0.001MΩ/0.1MΩ | ±(1.2%+3) | |
| Capacitance | 40nF/400nF/4μF | 0.01nF/0.1nF/0.001μF | ±(4.0%+5) |
| 40μF/400μF/4000μF | 0.01μF/0.1μF/1μF | ±(4.0%+5) | |
| Frequency (A) | 100Hz/1kHz | 0.01Hz/0.1Hz | ±(1.5%+5) |
| >1kHz | 0.001kHz | Take it only as reference | |
| Frequency (V) | 100Hz/1kHz/10kHz | 0.01Hz/0.1Hz/0.001kHz | ±(1.5%+5) |
| >10kHz | 0.01kHz | Take it only as reference | |
| Duty Cycle | 0.1%~99% | 0.10% | ±3.0% |
General Specifications
- Power Supply: 3 × 1.5V AAA Batteries
- Product Size: 222mm × 86mm × 32mm (8.74" × 3.38" × 1.26")
- Product Weight: 323g (0.71lb)
- Certification: RoHS
- Safety Rating: CAT III 600V
- Display Type: Digital Only

6. Setup
6.1 Battery Installation
- Ensure the meter is turned off and disconnect any test leads from the input terminals.
- Locate the battery compartment cover on the back of the meter.
- Use a screwdriver to open the battery compartment.
- Insert three 1.5V AAA batteries, observing the correct polarity (+ and -).
- Replace the battery compartment cover and secure it with the screw.
6.2 Connecting Test Leads
For voltage, resistance, capacitance, frequency (V), diode, and continuity measurements, connect the test leads:
- Insert the black test lead into the "COM" (common) input jack.
- Insert the red test lead into the "VΩHz" input jack.
7. Operating Instructions
To operate the clamp meter, turn the rotary switch to the desired function. The meter will automatically select the appropriate range unless manual ranging is activated.
7.1 AC/DC Current Measurement (Clamping)
To measure AC or DC current, use the clamp jaw:
- Turn the rotary switch to the "A~" (AC Current) or "A=" (DC Current) position.
- Open the clamp jaw by pressing the trigger.
- Enclose only one conductor (wire) of the circuit within the clamp jaw. Ensure the jaw is fully closed.
- Read the current value on the display.
- For DC current, the MS2138R model features a DCA automatic zero return key for accurate readings.

7.2 AC/DC Voltage Measurement
To measure AC or DC voltage:
- Connect the test leads as described in Section 6.2.
- Turn the rotary switch to the "V~" (AC Voltage) or "V=" (DC Voltage) position.
- Touch the red test lead to the positive side of the circuit and the black test lead to the negative side (or neutral/ground for AC).
- Read the voltage value on the display.

7.3 Resistance Measurement
To measure resistance:
- Ensure the circuit is de-energized before measuring resistance.
- Connect the test leads as described in Section 6.2.
- Turn the rotary switch to the "Ω" (Resistance) position.
- Touch the test leads across the component or circuit to be measured.
- Read the resistance value on the display.

7.4 Capacitance Measurement
To measure capacitance:
- Ensure the capacitor is fully discharged before measurement.
- Connect the test leads as described in Section 6.2.
- Turn the rotary switch to the "μF" (Capacitance) position.
- Touch the test leads across the capacitor terminals.
- Read the capacitance value on the display.

7.5 Frequency and Duty Cycle Measurement
To measure frequency (Hz) or duty cycle (%):
- Connect the test leads as described in Section 6.2 for voltage-based frequency, or use the clamp for current-based frequency.
- Turn the rotary switch to the "Hz%" position.
- Apply the test leads or clamp the conductor to the signal source.
- Read the frequency or duty cycle value on the display. Use the "FUNC" button to toggle between Hz and %.

7.6 Diode Test
To test diodes:
- Ensure the circuit is de-energized.
- Connect the test leads as described in Section 6.2.
- Turn the rotary switch to the diode symbol position.
- Place the red test lead on the anode and the black test lead on the cathode of the diode.
- Read the forward voltage drop on the display. Reverse the leads to check for open circuit.

7.7 Continuity Test
To check for continuity:
- Ensure the circuit is de-energized.
- Connect the test leads as described in Section 6.2.
- Turn the rotary switch to the continuity symbol position.
- Touch the test leads across the circuit or component.
- A buzzer will sound if continuity is detected (resistance less than 50 ±20Ω).

7.8 Additional Functions
- Data Hold (HOLD button): Press to freeze the current reading on the display. Press again to release.
- Relative Measurement (REL button): Press to store the current reading as a reference value. Subsequent measurements will be displayed as a difference from this reference.
- Backlight / Work Light: Activate the display backlight and/or work light for improved visibility in dark environments.
- Auto Power Off: The meter will automatically power off after a period of inactivity to conserve battery life.
8. Maintenance
8.1 Cleaning
Wipe the meter casing with a damp cloth and mild detergent. Do not use abrasives or solvents. Ensure the meter is completely dry before use.
8.2 Battery Replacement
When the low battery indicator appears on the display, replace the batteries as described in Section 6.1. Use three new 1.5V AAA batteries.
8.3 Storage
If the meter is not used for an extended period, remove the batteries to prevent leakage. Store the meter in its carry bag in a cool, dry place, away from direct sunlight and extreme temperatures.
9. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Meter does not power on | Dead or incorrectly installed batteries | Check battery polarity and replace batteries if necessary. |
| No reading or "OL" (Overload) displayed | Incorrect function selected, out of range, or open circuit | Select the correct function. If in manual range, switch to a higher range. Check for open circuits or ensure test leads are properly connected. |
| Inaccurate readings | Low battery, dirty test leads, or external interference | Replace batteries. Clean test leads. Move away from strong electromagnetic fields. |
| Continuity buzzer not working | Resistance too high, or function not selected | Ensure resistance is below 50 ±20Ω. Select continuity function. |
10. User Tips
No specific user tips were available from provided reviews or Q&A. Always refer to the detailed operating instructions for best results.