PowMr POW-LVM2.4K-24V

Contents

PowMr 3KVA 2.4KW All-in-One Solar Hybrid Inverter

Model: POW-LVM2.4K-24V

User Manual

1. Introduction

This manual provides essential information for the safe installation, operation, and maintenance of your PowMr 3KVA 2.4KW All-in-One Solar Hybrid Inverter. This unit combines the functions of an inverter, solar charger, and battery charger to offer uninterruptible power support in a single package. It is designed for off-grid applications, providing a pure sine wave output for sensitive electronics.

Key Features:

  • Pure sine wave output for compatibility with various loads.
  • Configurable input voltage range for home appliances and personal computers via LCD setting.
  • Configurable battery charging current based on applications via LCD setting.
  • Configurable AC/Solar Charger priority via LCD setting.
  • Compatible with mains voltage or generator power.
  • Automatic restart while AC is recovering.
  • Comprehensive protection against overload, over temperature, and short circuit.
  • Smart battery charger design for optimized battery performance.
  • Cold start function.
Front view of the PowMr 2.4KW Hybrid Inverter, highlighting 2400W, 110/120V AC output, 50A PWM Solar Charging, and 24V DC Battery Voltage.
Figure 1: PowMr 2.4KW Hybrid Inverter Overview

2. Safety Instructions

Please read all instructions and cautionary markings on the unit and in this manual before installation and operation. Failure to follow these instructions may result in electric shock, fire, or severe injury.

  • Only qualified personnel should install and service this device.
  • Do not disassemble the unit. There are no user-serviceable parts inside.
  • Ensure all wiring is correctly sized and properly terminated.
  • Always disconnect all power sources (AC, solar, and battery) before performing any wiring or maintenance.
  • Do not install the inverter on flammable surfaces or near flammable materials.
  • Ensure adequate ventilation around the inverter to prevent overheating.
  • This inverter is designed for single-phase 110V-120V AC output systems only.

3. Product Components and Overview

Familiarize yourself with the inverter's display, indicators, buttons, and connection ports.

Front and rear panel diagram of the PowMr inverter, labeling LCD display, indicators, buttons, and connection ports (AC input/output, PV input, DC input/battery, RS232, ON/OFF switch).
Figure 2: Inverter Front and Rear Panel Layout
  1. LCD display
  2. Status indicator
  3. Charging Indicator
  4. Fault Indicator
  5. Function buttons (ESC, UP, DOWN, ENTER)
  6. Circuit breaker
  7. AC input
  8. Dry connect
  9. PV input
  10. ON/OFF switch
  11. AC output
  12. RS232 Communication port
  13. DC input/Battery input
Side view of the PowMr inverter with a detailed specification label.
Figure 3: Inverter Side View with Specification Label

4. Installation and Setup

4.1 Mounting the Unit

Consider the following points before selecting where to install your inverter:

  • Do not mount the inverter on flammable construction materials.
  • Mount on a solid surface.
  • Install this inverter at eye level to allow the LCD display to be read at all times.
  • For proper air circulation to dissipate heat, allow a clearance of approximately 20 cm to the side and approximately 50 cm above and below the unit.
  • The ambient temperature should be between 0°C and 55°C to ensure optimal operation.
  • The recommended installation position is to be adhered to the wall vertically.
  • Be sure to keep other objects and surfaces as shown in the diagram to guarantee sufficient heat dissipation and to have enough space for removing wires.
Mounting instructions diagram for the PowMr inverter, showing recommended clearances (20cm side, 50cm top/bottom) and emphasizing mounting on a solid, non-combustible surface.
Figure 4: Recommended Mounting Clearances

4.2 Battery Connection

Follow these steps to implement battery connection:

  1. Assemble battery ring terminals based on recommended battery cable and terminal size.
  2. The 2.4KW model supports a 24VDC system. Connect all battery packs as shown in the chart below. It is suggested to connect at least 100Ah capacity battery for the 2.4KW model.
Battery connection diagram for the 2.4KW model, showing two 12V batteries connected in series to the inverter.
Figure 5: Battery Connection Diagram (24V System)

This inverter is compatible with Flooded, AGM, Gel, and Sealed Lead Acid Batteries. Lithium batteries are not explicitly listed as compatible.

4.3 Solar Panel Connection

Connect your solar panels to the PV input terminals. Ensure that the total PV array power does not exceed 1200W and the Max. PV Array Open Circuit Voltage does not exceed 80Vdc.

5. Operation

5.1 Charging Modes

The inverter supports four charging modes, configurable via the LCD setting:

  • Solar First: Prioritizes solar power for charging.
  • Utility First: Prioritizes utility (grid) power for charging.
  • Solar and Utility: Uses both solar and utility power for charging.
  • Only Solar: Charges exclusively from solar power.

5.2 Load Output Working Modes

The inverter offers three load output working modes:

  • Utility First: Prioritizes utility power to supply the load.
  • Solar First: Prioritizes solar power to supply the load.
  • SBU First (Solar-Battery-Utility): Prioritizes solar, then battery, then utility power to supply the load.
Diagram showing four charging modes (Solar First, Utility First, Solar and Utility, Only Solar) and three load output working modes (Utility First, Solar First, SBU First) for the PowMr inverter.
Figure 6: Charging and Output Modes

6. Specifications

Detailed technical specifications for the PowMr 3KVA 2.4KW All-in-One Solar Hybrid Inverter (Model POW-LVM2.4K-24V).

Comprehensive specifications diagram for the PowMr inverter, detailing AC input, frequency, AC charge current, battery type, recommended capacity, AC output power, rate voltage, Max PV input current, PV open circuit voltage, system DC voltage, and operating voltage range.
Figure 7: Detailed Specifications
CategoryParameterValue (POW-LVM2.4K-24V)
Inverter ModeInput Voltage WaveformSinusoidal (utility or generator)
Nominal Input Voltage120Vac
Max AC Input Voltage150Vac
Nominal Input Frequency50Hz/60Hz (Auto detection)
Output Short Circuit ProtectionCircuit Breaker
Transfer Time10ms typical (UPS); 20ms typical (Appliances)
Rated Output Power3KVA/2.4KW
Output Voltage WaveformPure Sine Wave
Peak Efficiency90%
Overload Protection5s@≥150% load; 10s@110%~150% load
Surge Capacity2 * rated power for 5 seconds
Nominal DC Input Voltage24Vdc
No Load Power Consumption<20W
Solar Charging ModeMax. PV Array Power1200W
Charging Current (PWM)50Amp
System DC Voltage24Vdc
Operating Voltage Range30~32Vdc
Max. PV Array Open Circuit Voltage80Vdc
Joint Utility and Solar ChargingMax Charging Current80Amp
Default Charging Current50Amp
General SpecificationsSafety CertificationCE
Operating Temperature Range0℃ to 55℃
Storage temperature-15℃~60℃
Net Weight7.5KG
PowMr inverter dimensions (13.97in height, 10.7in width, 3.9in depth) and key specifications like Rated Output Power (2400W), Max Solar Charge Current (50A), Charging Current PWM (50AMP 24VDC), and Max. PV Array Open Circuit Voltage (80VDC).
Figure 8: Inverter Dimensions and Key Electrical Specifications

7. Troubleshooting

This section provides solutions to common issues you might encounter with your inverter.

Common Protections:

Image highlighting multi-protections of the PowMr inverter: Short Circuit, Over/Under Voltage, Over Load, and Reverse Polarity.
Figure 9: Inverter Multi-Protections
  • Short Circuit Protection: The inverter will shut down if a short circuit is detected on the output. Remove the short and restart the unit.
  • Over/Under Voltage Protection: The inverter will protect itself from input voltage outside the specified range. Check input voltage and correct.
  • Overload Protection: If the connected load exceeds the inverter's capacity, it will trigger an overload alarm and shut down. Reduce the load and restart.
  • Reverse Polarity Protection: Protects against incorrect battery connection. Ensure correct polarity when connecting batteries.

General Issues:

  • No Power Output: Check battery connections, AC input (if applicable), solar panel connections, and the ON/OFF switch. Verify circuit breakers are not tripped.
  • Inverter Not Charging Batteries: Ensure solar panels are receiving adequate sunlight and are connected correctly. Check AC input if utility charging is enabled. Verify battery type settings on the LCD.
  • LCD Display Not Working: Check power supply to the inverter. If power is present, contact support.

8. User Tips

  • Solar Panel Sizing: When connecting solar panels, ensure the total power does not exceed 1200W and the open circuit voltage (Voc) does not exceed 80Vdc to prevent damage to the unit. For example, if using 575W panels, you can connect a maximum of two panels in series if their combined voltage is within the 80Vdc limit.
  • Battery Compatibility: This inverter is designed for Flooded, AGM, Gel, and Sealed Lead Acid batteries. It does not explicitly support Lithium batteries. Always verify battery compatibility before connection.
  • Prioritize Solar: Utilize the 'Solar First' charging and output modes to maximize energy independence and reduce reliance on grid power.

9. Maintenance

  • Regular Cleaning: Keep the inverter's ventilation openings clear of dust and debris to ensure proper airflow and prevent overheating. Use a dry cloth for cleaning.
  • Connection Checks: Periodically inspect all wiring connections (battery, solar, AC) to ensure they are tight and free from corrosion.
  • Battery Health: Monitor battery voltage and performance regularly. Follow your battery manufacturer's maintenance guidelines.
  • Environmental Conditions: Ensure the inverter remains within its specified operating temperature range (0°C to 55°C) and is protected from moisture.

10. Warranty and Support

For warranty information, technical support, or service inquiries, please contact your original point of purchase or the manufacturer directly. Ensure you have your product model number (POW-LVM2.4K-24V) and serial number available when contacting support.

11. Applications

The PowMr 3KVA 2.4KW All-in-One Solar Hybrid Inverter is suitable for a variety of off-grid power needs.

Image showing various applications for the PowMr inverter, including RV, Home Storage, Camping, and Solar Power System.
Figure 10: Typical Applications
  • RV and Mobile Power Systems
  • Home Backup Power and Off-Grid Home Storage
  • Camping and Outdoor Power Solutions
  • General Solar Power Systems

Ask a question about this manual