1. Introduction
This manual provides essential information for the safe installation, operation, and maintenance of your PowMr 3KVA 2.4KW All-in-One Solar Hybrid Inverter. This unit combines the functions of an inverter, solar charger, and battery charger to offer uninterruptible power support in a single package. It is designed for off-grid applications, providing a pure sine wave output for sensitive electronics.
Key Features:
- Pure sine wave output for compatibility with various loads.
- Configurable input voltage range for home appliances and personal computers via LCD setting.
- Configurable battery charging current based on applications via LCD setting.
- Configurable AC/Solar Charger priority via LCD setting.
- Compatible with mains voltage or generator power.
- Automatic restart while AC is recovering.
- Comprehensive protection against overload, over temperature, and short circuit.
- Smart battery charger design for optimized battery performance.
- Cold start function.

2. Safety Instructions
Please read all instructions and cautionary markings on the unit and in this manual before installation and operation. Failure to follow these instructions may result in electric shock, fire, or severe injury.
- Only qualified personnel should install and service this device.
- Do not disassemble the unit. There are no user-serviceable parts inside.
- Ensure all wiring is correctly sized and properly terminated.
- Always disconnect all power sources (AC, solar, and battery) before performing any wiring or maintenance.
- Do not install the inverter on flammable surfaces or near flammable materials.
- Ensure adequate ventilation around the inverter to prevent overheating.
- This inverter is designed for single-phase 110V-120V AC output systems only.
3. Product Components and Overview
Familiarize yourself with the inverter's display, indicators, buttons, and connection ports.

- LCD display
- Status indicator
- Charging Indicator
- Fault Indicator
- Function buttons (ESC, UP, DOWN, ENTER)
- Circuit breaker
- AC input
- Dry connect
- PV input
- ON/OFF switch
- AC output
- RS232 Communication port
- DC input/Battery input

4. Installation and Setup
4.1 Mounting the Unit
Consider the following points before selecting where to install your inverter:
- Do not mount the inverter on flammable construction materials.
- Mount on a solid surface.
- Install this inverter at eye level to allow the LCD display to be read at all times.
- For proper air circulation to dissipate heat, allow a clearance of approximately 20 cm to the side and approximately 50 cm above and below the unit.
- The ambient temperature should be between 0°C and 55°C to ensure optimal operation.
- The recommended installation position is to be adhered to the wall vertically.
- Be sure to keep other objects and surfaces as shown in the diagram to guarantee sufficient heat dissipation and to have enough space for removing wires.

4.2 Battery Connection
Follow these steps to implement battery connection:
- Assemble battery ring terminals based on recommended battery cable and terminal size.
- The 2.4KW model supports a 24VDC system. Connect all battery packs as shown in the chart below. It is suggested to connect at least 100Ah capacity battery for the 2.4KW model.

This inverter is compatible with Flooded, AGM, Gel, and Sealed Lead Acid Batteries. Lithium batteries are not explicitly listed as compatible.
4.3 Solar Panel Connection
Connect your solar panels to the PV input terminals. Ensure that the total PV array power does not exceed 1200W and the Max. PV Array Open Circuit Voltage does not exceed 80Vdc.
5. Operation
5.1 Charging Modes
The inverter supports four charging modes, configurable via the LCD setting:
- Solar First: Prioritizes solar power for charging.
- Utility First: Prioritizes utility (grid) power for charging.
- Solar and Utility: Uses both solar and utility power for charging.
- Only Solar: Charges exclusively from solar power.
5.2 Load Output Working Modes
The inverter offers three load output working modes:
- Utility First: Prioritizes utility power to supply the load.
- Solar First: Prioritizes solar power to supply the load.
- SBU First (Solar-Battery-Utility): Prioritizes solar, then battery, then utility power to supply the load.

6. Specifications
Detailed technical specifications for the PowMr 3KVA 2.4KW All-in-One Solar Hybrid Inverter (Model POW-LVM2.4K-24V).

| Category | Parameter | Value (POW-LVM2.4K-24V) |
|---|---|---|
| Inverter Mode | Input Voltage Waveform | Sinusoidal (utility or generator) |
| Nominal Input Voltage | 120Vac | |
| Max AC Input Voltage | 150Vac | |
| Nominal Input Frequency | 50Hz/60Hz (Auto detection) | |
| Output Short Circuit Protection | Circuit Breaker | |
| Transfer Time | 10ms typical (UPS); 20ms typical (Appliances) | |
| Rated Output Power | 3KVA/2.4KW | |
| Output Voltage Waveform | Pure Sine Wave | |
| Peak Efficiency | 90% | |
| Overload Protection | 5s@≥150% load; 10s@110%~150% load | |
| Surge Capacity | 2 * rated power for 5 seconds | |
| Nominal DC Input Voltage | 24Vdc | |
| No Load Power Consumption | <20W | |
| Solar Charging Mode | Max. PV Array Power | 1200W |
| Charging Current (PWM) | 50Amp | |
| System DC Voltage | 24Vdc | |
| Operating Voltage Range | 30~32Vdc | |
| Max. PV Array Open Circuit Voltage | 80Vdc | |
| Joint Utility and Solar Charging | Max Charging Current | 80Amp |
| Default Charging Current | 50Amp | |
| General Specifications | Safety Certification | CE |
| Operating Temperature Range | 0℃ to 55℃ | |
| Storage temperature | -15℃~60℃ | |
| Net Weight | 7.5KG |

7. Troubleshooting
This section provides solutions to common issues you might encounter with your inverter.
Common Protections:

- Short Circuit Protection: The inverter will shut down if a short circuit is detected on the output. Remove the short and restart the unit.
- Over/Under Voltage Protection: The inverter will protect itself from input voltage outside the specified range. Check input voltage and correct.
- Overload Protection: If the connected load exceeds the inverter's capacity, it will trigger an overload alarm and shut down. Reduce the load and restart.
- Reverse Polarity Protection: Protects against incorrect battery connection. Ensure correct polarity when connecting batteries.
General Issues:
- No Power Output: Check battery connections, AC input (if applicable), solar panel connections, and the ON/OFF switch. Verify circuit breakers are not tripped.
- Inverter Not Charging Batteries: Ensure solar panels are receiving adequate sunlight and are connected correctly. Check AC input if utility charging is enabled. Verify battery type settings on the LCD.
- LCD Display Not Working: Check power supply to the inverter. If power is present, contact support.
8. User Tips
- Solar Panel Sizing: When connecting solar panels, ensure the total power does not exceed 1200W and the open circuit voltage (Voc) does not exceed 80Vdc to prevent damage to the unit. For example, if using 575W panels, you can connect a maximum of two panels in series if their combined voltage is within the 80Vdc limit.
- Battery Compatibility: This inverter is designed for Flooded, AGM, Gel, and Sealed Lead Acid batteries. It does not explicitly support Lithium batteries. Always verify battery compatibility before connection.
- Prioritize Solar: Utilize the 'Solar First' charging and output modes to maximize energy independence and reduce reliance on grid power.
9. Maintenance
- Regular Cleaning: Keep the inverter's ventilation openings clear of dust and debris to ensure proper airflow and prevent overheating. Use a dry cloth for cleaning.
- Connection Checks: Periodically inspect all wiring connections (battery, solar, AC) to ensure they are tight and free from corrosion.
- Battery Health: Monitor battery voltage and performance regularly. Follow your battery manufacturer's maintenance guidelines.
- Environmental Conditions: Ensure the inverter remains within its specified operating temperature range (0°C to 55°C) and is protected from moisture.
10. Warranty and Support
For warranty information, technical support, or service inquiries, please contact your original point of purchase or the manufacturer directly. Ensure you have your product model number (POW-LVM2.4K-24V) and serial number available when contacting support.
11. Applications
The PowMr 3KVA 2.4KW All-in-One Solar Hybrid Inverter is suitable for a variety of off-grid power needs.

- RV and Mobile Power Systems
- Home Backup Power and Off-Grid Home Storage
- Camping and Outdoor Power Solutions
- General Solar Power Systems