1. Introduction

The XikeStor SKS3200-8E1X-P is a 9-port 2.5G lite-managed Ethernet switch with 10G uplink, designed for high-speed and stable data transmission. It is suitable for various network environments, from large-scale data centers and cloud computing platforms to security video surveillance networks, hotels, campuses, and small to medium-sized enterprise network projects.

This switch features web management functions, supporting VLAN division, port aggregation, port mirroring, and QoS data prioritization, making it adaptable to complex networking scenarios. It offers excellent scalability and seamless integration with existing network devices.

XikeStor SKS3200-8E1X-P Simple L2 Managed POE Switch front view
Figure 1: XikeStor SKS3200-8E1X-P Simple L2 Managed POE Switch

2. Key Features

  • 8 x 100/1000/2500M RJ45 ports + 1 x 10G SFP optical port
  • Complies with IEEE 802.3, 802.3u, 802.3ab, 802.3bz, 802.3ae, and 802.3x standards
  • Ethernet ports support 100/1000M/2500M auto-negotiation
  • Supports Auto MDI/MDIX
  • Front panel LED indicators for monitoring status and troubleshooting
  • Flow control: IEEE802.3x (full-duplex), Backpressure (half-duplex)
  • Supports QoS data prioritization
  • Web management for VLAN, Port Aggregation, QoS, Loop Setup, Bandwidth Control
  • High specification lightning protection (6KV lightning, 8KV static electricity)
  • Metal shell for durability and passive heat dissipation
Diagram showing POE power supply capabilities of the switch
Figure 2: POE Power Supply Overview. The switch provides 2.5G RJ45 ports with intelligent power supply, supporting 802.3AF/AT protocol, up to 30W per port, and a total power supply of 150W. It automatically identifies and powers devices while retaining data exchange functions. Devices like PCs, surveillance cameras, APs, and NAS can be powered.
Diagram illustrating network management functions
Figure 3: Network Management Functions. The switch supports web management for simple operation, allowing configuration of VLAN, QoS data prioritization, link aggregation (static and LACP), loop settings, and bandwidth control to manage complex networking scenarios. This includes features like Bandwidth Control, Link Aggregation, Loop Setup, QoS Data Prioritization, VLAN Segmentation, and IGMP Listening.

3. Package Contents

Verify that all items are present and in good condition. If any item is missing or damaged, contact your vendor.

  • Switch x1
  • User manual x1
  • Certificate x1
  • Power adapter x1
  • Rubber feet x4
  • Grounding screw x1

4. Setup Instructions

4.1 Physical Installation

  1. Placement: Place the switch on a stable, flat surface or mount it in a rack. Ensure adequate ventilation around the device.
  2. Power Connection: Connect the provided power adapter to the switch's power input (DC 12V1A) and then to a suitable power outlet (AC 100-240V).
  3. Grounding: For enhanced protection, connect the grounding screw to a proper ground.
  4. Attach Rubber Feet: If placing on a surface, attach the four rubber feet to the bottom of the switch to prevent slipping and provide minor elevation for airflow.

4.2 Network Connections

  1. RJ45 Ports (1-8): Connect your network devices (e.g., PCs, surveillance cameras, APs, NAS) to the 8 x 100/1000/2500M RJ45 ports using Cat5e or higher UTP/STP cables for 2.5GBase-T connections, or Cat3/4/5 for 10/100/1000M connections. These ports support PoE for compatible devices.
  2. SFP+ Port (Port 9): Insert a compatible 1G/2.5G/10G SFP+ module into the SFP+ slot. Connect fiber optic cables (e.g., MMF for 1000BASE-SX/10GBASE-SR, SMF for 1000BASE-LX/2500BASE-X/10GBASE-LR) to the SFP+ module for high-speed uplink connections.
Front view of the SKS3200-8E1X-P switch showing ports and indicators
Figure 4: Front Panel Layout. This image shows the front panel of the SKS3200-8E1X-P switch, highlighting the 8 RJ45 ports, 1 SFP+ port, and LED indicators for Power (PWR), System (SYS), Link/Act, and PoE status.
Diagram showing 10Gb SFP+ ports for various connections
Figure 5: 10Gb SFP+ Port Capabilities. The SFP+ port supports 1G/2.5G/10G rates and is compatible with various modules, DAC, and AOC cables, allowing connection to a variety of devices. It also supports multi-brand PON Stick access networking, overcoming Gigabit broadband limitations.

5. Operating Instructions

5.1 Power On/Off

  • Power On: After connecting the power adapter, the switch will automatically power on. The PWR LED will illuminate.
  • Power Off: Disconnect the power adapter from the power source.

5.2 LED Indicators

IndicatorStatusDescription
PWROnPower on
PWROffNo power
SYSOnSystem normal
SYSBlinkingSystem booting
Ports 1-8Green on2.5G link normal
Ports 1-8Yellow on10/100/1000M link normal
Ports 1-8OffNo link
Ports 1-8BlinkingData transfer
Port 9 (SFP)Green on10G/2.5G link normal
Port 9 (SFP)Yellow on1G link normal
Port 9 (SFP)OffNo link
Port 9 (SFP)BlinkingData transfer

5.3 Web Management

The switch supports web-based management for advanced configuration. To access the web interface:

  1. Connect a computer to any of the switch's RJ45 ports.
  2. Configure your computer's IP address to be in the same subnet as the switch's default management IP (refer to the full user manual PDF for default IP).
  3. Open a web browser and enter the switch's management IP address.
  4. Log in using the default credentials (refer to the full user manual PDF for default credentials).
  5. From the web interface, you can configure:
    • VLANs (802.1Q VLAN segmentation)
    • Port Aggregation (Static and LACP)
    • QoS (Traffic classification, SP and WRR scheduling, Port priority, up to 8 queues per port)
    • Port Mirroring
    • Port Security (MAC address limitation)
    • Port Rate Limiting
    • Loop Detection
    • Storm Control (Broadcast, Unknown Multicast, Unknown Unicast suppression)
    • Firmware upgrades and configuration backup/restore

For detailed instructions on specific configurations, please refer to the comprehensive user manual PDF available at XikeStor SKS3200-8E1X-P User Manual (PDF).

Video 1: Product Overview. This video provides a visual overview of the XikeStor SKS3200-8E1X-P switch, showcasing its design and key features.

6. Maintenance

6.1 General Care

  • Keep the switch in a clean, dry environment.
  • Ensure proper ventilation to prevent overheating. The switch uses passive heat dissipation.
  • Avoid exposing the device to extreme temperatures or humidity.
  • Clean the exterior with a soft, dry cloth. Do not use liquid cleaners.

6.2 Firmware Updates

Periodically check the manufacturer's website for firmware updates. Firmware updates can improve performance, add new features, and fix bugs. Refer to the web management section for instructions on how to upgrade firmware.

6.3 Factory Reset

If you encounter persistent issues or forget your management credentials, you can restore the switch to factory settings:

  • Locate the Reset button on the front panel.
  • With the switch powered on, press and hold the Reset button for 6 seconds.
  • The switch will reboot with factory default settings.

7. Troubleshooting

7.1 No Power

  • Ensure the power adapter is securely connected to the switch and a working power outlet.
  • Check if the power outlet is functional.
  • Verify the PWR LED is on. If not, check the power connections.
  • Check the Ethernet cables for proper connection and damage.
  • Ensure the connected device is powered on and functioning correctly.
  • Observe the Link/Act LEDs for the respective port. If off, there is no link.
  • Verify that the connected device's network settings are correct (e.g., IP address, subnet mask).
  • For SFP+ ports, ensure the SFP+ module is correctly inserted and compatible, and the fiber cable is intact.

7.3 Slow Network Speed

  • Check the Link/Act LED color for the port. Green indicates 2.5G, Yellow indicates 10/100/1000M. Ensure your devices support 2.5G for optimal speed.
  • Verify that the network cables meet the required specifications (e.g., Cat5e or higher for 2.5G).
  • Check for network congestion or loop issues. The switch supports loop detection.
  • Review QoS settings via web management to ensure traffic prioritization is configured as desired.

7.4 Cannot Access Web Management

  • Ensure your computer's IP address is in the same subnet as the switch's management IP.
  • Verify the physical connection between your computer and the switch.
  • Try resetting the switch to factory defaults if you suspect incorrect configuration or forgotten credentials.

8. Technical Specifications

ParameterValue
Model NumberSKS3200-8E1X-P
Main Control ChipRTL8373N
I/O Interfaces8 x 100/1000/2500M RJ45, 1 x 10G SFP+
Power Supply (Adapter)AC 100-240V
Power Supply (Switch)DC 12V1A
Power Consumption24W Max
Backplane Bandwidth60Gbps
Packet Forwarding Rate44.64Mpps
Packet Buffer8Mbit
Jumbo Frame16356 bytes
MAC Address Table4K
Forwarding ModeStore and Forward
VLANRange 1-4094, up to 31 active VLANs
Heat Dissipation ModePassive heat dissipation
Dimensions (L x W x H)156.2 x 94 x 37 mm
Operating Temperature-10°C to 50°C
Storage Temperature-40°C to 70°C
Operating Humidity10%-90%, non-condensing
Storage Humidity5%-95%, non-condensing
CertificationsCE, FCC, RoHS, PSE, UKCA, WEEE

8.1 Network Protocols & Standards

  • IEEE 802.3 (Ethernet)
  • IEEE 802.3u (Fast Ethernet)
  • IEEE 802.3ab (Gigabit Ethernet)
  • IEEE 802.3bz (2.5G/5G Ethernet)
  • IEEE 802.3z (Gigabit Ethernet)
  • IEEE 802.3ae (10G Ethernet)
  • IEEE 802.3x (Flow Control)
  • IEEE 802.1D Spanning Tree Protocol
  • IEEE 802.1w Rapid Spanning Tree Protocol
  • IEEE 802.1Q VLAN tagging
  • RFC 768 UDP, RFC 791 IP, RFC 792 ICMP, RFC 2068 HTTP, RFC 1112 IGMP v1, RFC 2236 IGMP v2

8.2 Cabling Requirements

  • 10Base-T: Cat3/4/5 or higher UTP/STP (≤100m)
  • 100Base-TX: Cat5 or higher UTP/STP (≤100m)
  • 1000Base-TX: Cat5 or higher UTP/STP (≤100m)
  • 2.5GBase-T: Cat5e or higher UTP/STP (≤100m)
  • 5GBase-T: Cat6 or higher UTP/STP (≤100m)
  • 10GBase-T: Cat6a or higher UTP/STP (≤100m)
  • 1000BASE-SX: 62.5µm MMF (2m-275m) or 50µm MMF
  • 1000BASE-LX: 62.5µm/50µm MMF (2m-550m) or 10µm SMF (2m-5km)
  • 2500BASE-X: G.652D SMF (2m-500m or 2m-5km)
  • 10GBASE-SR: OM1/OM2/OM3 or higher MMF (2m-300m)
  • 10GBASE-LR: IEC B1.1 and B1.3 compliant SMF (2m-10km)

9. User Tips

No specific user reviews or Q&A content were provided to generate user tips. However, based on the product's features, here are some general tips:

  • Leverage Web Management: For optimal network performance and security, utilize the web management interface to configure VLANs, QoS, and link aggregation according to your network's specific needs.
  • Check Firmware Regularly: Keep the switch's firmware updated to benefit from the latest features, performance improvements, and security patches.
  • Cable Quality Matters: For 2.5G and 10G connections, ensure you use high-quality Ethernet cables (Cat5e or higher) and appropriate fiber optic cables to achieve advertised speeds and stability.
  • PoE Planning: When using PoE, ensure your powered devices (PDs) are 802.3AF/AT compliant and that the total power consumption does not exceed the switch's 150W budget.

10. Warranty and Support

For warranty information, technical support, or further assistance, please refer to the official XikeStor website or contact your vendor directly. The full user manual PDF contains more detailed information regarding support and service.

Full User Manual (PDF): XikeStor SKS3200-8E1X-P User Manual (PDF)

© 2023 XikeStor. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.