Hantek TO1152D

Contents

Hantek TO1152D Multi-function Full Touch Screen Tablet Digital Oscilloscope User Manual

Model: TO1152D | Brand: Hantek

1. Introduction

The Hantek TO1152D is a new generation multi-function full touch screen tablet digital oscilloscope designed for portability and versatility. It integrates an oscilloscope, multimeter, signal generator, and spectrum analyzer into a single, compact device. Its thin and lightweight body, combined with a unique hanging design, makes it easy to carry and use in various environments. The device features a durable, anti-fall and shock-resistant construction, and is powered by a large-capacity battery with fast charging support for extended operation.

Video: Hantek TO1000 Series Product Overview, showcasing its multi-functionality and portability.

Hantek TO1152D main screen showing icons for Oscilloscope, DMM, AFG, H/R, and Print functions.

Image: Main interface of the Hantek TO1152D, highlighting its integrated functions.

2. Package Contents

Please check the package carefully for the following items:

  • Hantek TO1152D Host Unit (x1)
  • Oscilloscope Probe (x2 for 4-channel models, x1 for 2-channel models)
  • Multimeter Probe (x1, for TO1000C/D Series standard configuration only)
  • Crocodile Clip (x2 for 4-channel models, x1 for 2-channel models; one additional for models with signal source function)
  • 18W Adapter (x1)
  • Type-C Charging Cable (x1)
  • Instrument Package (x1)
Hantek TO1152D Host Unit
Host Unit
Oscilloscope Probe
Oscilloscope Probe
Multimeter Probe
Multimeter Probe
Crocodile Clip
Crocodile Clip
18W Adapter and Type-C Charging Cable
18W Adapter & Type-C Cable
Instrument Package
Instrument Package

3. Setup

3.1 Battery Installation and Charging

The Hantek TO1152D comes with a built-in 10000mAh removable lithium battery. Ensure the battery is properly seated before first use. To charge the device, use the provided 18W adapter and Type-C charging cable. The device supports fast charging, allowing you to quickly replenish power. The Type-C interface is compatible with many mobile phone chargers, offering convenience.

Internal view of Hantek TO1152D showing four 18650 batteries.
Image: Internal battery compartment showing 4x 18650 batteries.
Side view of Hantek TO1152D showing Type-C charging port and USB port.
Image: Type-C fast charging port.

3.2 Initial Power-On

Press and hold the power button to turn on the device. The multi-touch screen will display the main interface, offering access to various functions.

3.3 Connecting Probes

Depending on the function you intend to use (oscilloscope or multimeter), connect the appropriate probes to the designated ports on the device. Ensure connections are secure.

Top view of Hantek TO1152D showing AFG, CH1, CH2, CH3, CH4 input ports.

Image: Input ports for AFG and Oscilloscope Channels (CH1-CH4).

4. Operating Instructions

4.1 General Touch Screen Operation

The device features a multi-touch large screen with an 800*480 resolution. The user interface is designed to be friendly and easy to use. Navigate through menus and adjust settings using touch gestures similar to a tablet device.

Hantek TO1152D screen showing a waveform being adjusted by touch.
Image: Touch screen interaction for waveform adjustment.
Hantek TO1152D screen showing a waveform being zoomed or panned by touch.
Image: Multi-touch gesture for zooming/panning waveforms.

4.2 Oscilloscope Function

The Hantek TO1152D functions as a 4-channel digital storage oscilloscope with a bandwidth up to 250MHz, a sampling rate of 1GS/s, and a storage depth of 8M. It supports various trigger types including edge, slope, pulse width, video, and timeout. Up to 42 measurement functions are available for comprehensive analysis.

Hantek TO1152D oscilloscope display showing multiple waveforms and measurement data.

Image: Oscilloscope display showing multiple channels and measurement results.

4.3 Signal Generator Function (AFG)

The arbitrary function signal generator offers an output frequency up to 25MHz, 12-bit high resolution, and a 200MS/s sampling rate. It includes a variety of built-in arbitrary waveforms and supports AM/FM modulation. The output resistance can be switched between high and low impedance.

Hantek TO1152D signal generator interface showing waveform selection and parameters.

Image: Signal Generator interface for waveform and parameter selection.

4.4 Digital Multimeter Function (DMM)

The high-precision multimeter function allows for AC and DC voltage, current, resistance, capacitance, diode, and on-off measurements. It also features a data recording function to monitor and record changes in these parameters over time, generating trend graphs or allowing data export.

Hantek TO1152D multimeter display showing voltage measurement and a trend graph.

Image: Multimeter display showing voltage measurement and data trend.

4.5 Waveform Storage

The device supports one-key waveform storage, providing a convenient and quick way to save important measurement data.

5. Maintenance

5.1 Cleaning

To clean the device, use a soft, dry cloth. For stubborn dirt, a slightly damp cloth with mild detergent can be used, ensuring no liquid enters the ports or screen edges. Do not use abrasive cleaners or solvents.

5.2 Battery Care

To maximize battery life, avoid fully discharging the device frequently. Store the device in a cool, dry place when not in use for extended periods. The device has a long-lasting battery life and can stand by for up to half a year, but regular charging is recommended if stored for very long durations.

5.3 General Care

The Hantek TO1152D features an anti-fall and shock-resistant design. However, avoid unnecessary drops or impacts. When using the hanging feet, ensure the device is securely placed to prevent accidental falls. Keep the device away from extreme temperatures, humidity, and direct sunlight.

6. Troubleshooting

  • Device does not power on: Ensure the battery is charged. Connect the device to the charger and try again. If the battery is removable, ensure it is correctly installed.
  • Screen unresponsive: Try restarting the device. If the issue persists, ensure the screen is clean and free from debris.
  • Inaccurate measurements: Check that probes are correctly connected and calibrated. Ensure the correct function mode (oscilloscope, multimeter) is selected for your measurement.
  • Fast battery drain: Reduce screen brightness or disable unused functions to conserve power. Ensure the device is fully charged before use.
  • Charging issues: Verify that the 18W adapter and Type-C cable are functioning correctly. Try a different compatible charger if available.

7. Specifications

FeatureSpecification (TO1000 Series)Specification (TO1112 Series)
Brand NameHantek
Model NumberTO1152D (Other models: TO1154D, TO1204D, TO1254D, TO1112, TO1112C, TO1112D)
CertificationCE
OriginMainland China
DIY SuppliesElectrical
Digital Channels42
Bandwidth100-349MHz (TO1152D: 150MHz, TO1204D: 200MHz, TO1254D: 250MHz)110MHz
Real Time Sampling Rate1GSa/S250MSa/S
Record Length8M
Max Waveform Capture Rate30,000wfm/s
Display Size5.0 - 6.9 Inches
Display Resolution640*480 Pixels
Battery IncludedYes
IS Battery DemountableYes
High-concerned chemicalNone
Horizontal Scale Range2ns/div~100s/div (1, 2, 5 sequence)2ns/div~100s/div (1, 2, 5 sequence)
Incremental Time Measurement Accuracy (Full Bandwidth)± (1 sampling interval +100ppm× reading +0.6ns)
>16 times on average
±(1 sampling interval +100ppm× reading +0.4ns)
Sampling interval = seconds/grid ÷200
± (1 sampling interval +100ppm× reading +0.6ns)
>16 times on average
±(1 sampling interval +100ppm× reading +0.4ns)
Sampling interval = seconds/grid ÷200
A/D Converter8-bit resolution, each channel sampled simultaneously
Vertical Scale Range2mV/div~10V/div at input BNC10mV/div~10V/div at input BNC
Vertical Resolution8bit
Vertical Sensitivity Range2mV/div~10V/div (TO1000 Series)
10mV/div~10V/div (TO1112 Series)
Offset Range±1V (2mV/div~100mV/div)
±10V (200mV/div~1V/div)
±50V (2V/div~10V/div)
±1Vmax (100mV/div)
±10Vmax (1V/div)
±50Vmax (10V/div)
Dynamic Range±5div (8bit)
Optional Analog Bandwidth Limitation, Typical20MHz, Each channel is independently selectable
DC Gain Accuracy±3% FullScale
Isolation Between Channels40dB, DC to the maximum rated bandwidth of each model
Note: Bandwidth reduced to 6MHz when using a 1X probe.
Detailed specifications table for Hantek TO1000 and TO1112 series oscilloscopes, covering horizontal and vertical settings.
Image: Detailed Oscilloscope Specifications (Part 1).
Detailed specifications table for Hantek TO1000 and TO1112 series oscilloscopes, covering DC gain, channel isolation, and acquisition modes.
Image: Detailed Oscilloscope Specifications (Part 2).
Model comparison table for Hantek TO1000 and TO1112 series, showing oscilloscope channels, bandwidth, sampling rate, storage depth, signal source, and multimeter availability.
Image: Model Comparison Table.

8. User Tips

  • Maximize Portability: Utilize the unique hanging design to free your hands when working in tight spaces or on the go.
  • Efficient Charging: Take advantage of the Type-C fast charging capability. You can often use your mobile phone's fast charger for convenience.
  • Data Logging: For long-term monitoring, remember to use the multimeter's data recording function to track trends in voltage, current, or resistance.
  • Quick Waveform Capture: Use the one-key waveform storage feature to quickly save important measurement results for later analysis.

9. Warranty and Support

For warranty information, technical support, or service inquiries, please refer to the official Hantek website or contact your authorized dealer. Keep your purchase receipt as proof of purchase for warranty claims.