1. Introduction
The Hantek TO1254C is a new generation multi-function full touch screen oscilloscope from the TO1000 series. It features a thin, lightweight, and portable design with a unique hanging mechanism for hands-free operation. This device integrates an oscilloscope, multimeter, signal generator, and spectrum analyzer into a single unit. It is built with anti-fall and shock-resistant corners for durability and includes a large-capacity battery for extended use and fast charging capabilities.
Video: Overview of the Hantek TO1000 series features, including portability, multi-functionality, and durability.
2. Key Features
- Multi-touch Large Screen: 800*480 resolution with a user-friendly interface for intuitive interaction.
- Oscilloscope: Standard 4 or 2 channels, up to 250MHz bandwidth, 1GS/s sampling rate, and 8M storage depth.
- High-Precision Multimeter: Functions include AC/DC voltage, current, resistance, capacitance, diode, and on-off measurement. Features data recording, storage, trend graphs, and statistical analysis.
- Signal Generator: Maximum output frequency up to 25MHz, 12-bit high resolution, 200MS/s sampling rate. Includes various arbitrary waveforms and supports AM/FM modulation.
- One-Key Waveform Storage: Convenient and quick saving of waveforms.
- Hanging Design: Unique hanging feet for multi-angle adjustment, anti-drop, and shock resistance, allowing flexible placement.
- Long-lasting Battery: Built-in 10000mAh removable lithium battery provides extended battery life and up to half a year of standby time.
- Fast Charging: Standard 18W charger with Type-C fast charging, compatible with mobile phone chargers.

Image: The Hantek TO1254C displaying its multi-function capabilities, including oscilloscope, multimeter, and signal generator modes.
3. Setup and Initial Use
3.1 Unpacking and Inspection
Carefully unpack the Hantek TO1254C and all accessories. Verify that all components listed in the "Product Accessories" section are present and undamaged. If any items are missing or damaged, contact your vendor immediately.
3.2 Charging the Device
The device comes with a built-in 10000mAh removable lithium battery. Before first use, it is recommended to fully charge the device. Use the provided 18W adapter and Type-C charging cable. The Type-C interface supports fast charging and is compatible with standard mobile phone chargers.

Image: The 18W adapter and Type-C charging cable for the Hantek TO1254C.
3.3 Powering On/Off
- To power on: Press and hold the power button located on the side of the device until the screen illuminates.
- To power off: Press and hold the power button until a shutdown prompt appears on the screen, then follow the on-screen instructions.
3.4 Initial Screen Navigation
The device features a multi-touch large screen with an intuitive UI. Navigate through the different functions (Oscilloscope, DMM, AFG, File Browser, Settings, Pictures) by tapping their respective icons on the home screen.

Image: The home screen of the Hantek TO1254C, showing icons for various functions like OSC (Oscilloscope), DMM (Digital Multimeter), and AFG (Arbitrary Function Generator).
4. Operating Instructions
4.1 Oscilloscope Function
The TO1254C is a 4-channel digital storage oscilloscope. To use the oscilloscope function:
- From the home screen, tap the "OSC" icon.
- Connect the oscilloscope probes (one for two-channel series, two for four-channel series) to the CH1, CH2, CH3, or CH4 input ports on the top of the device.
- Connect the probe to the circuit under test.
- Adjust the vertical scale (V/div) and horizontal scale (s/div) using the touch screen gestures (pinch-to-zoom) or on-screen controls.
- Configure trigger settings (Edge, Slope, Pulse Width, Video, Timeout) as needed for stable waveform capture.
- Utilize the 42 measurement functions for detailed analysis.

Image: The oscilloscope displaying multiple waveforms, indicating its multi-channel capability.

Image: Oscilloscope probes, essential for signal input. One probe is included for two-channel series, and two for four-channel series.
4.2 Digital Multimeter (DMM) Function
The DMM function allows for precise measurements of various electrical parameters.
- From the home screen, tap the "DMM" icon.
- Connect the multimeter probes to the appropriate input jacks (V/Ω/C, COM, mA, A) on the side of the device.
- Select the desired measurement mode (AC/DC voltage, current, resistance, capacitance, diode, continuity) on the screen.
- Place the probes across the component or circuit to be measured.
- The DMM also supports data recording, trend graphs, and statistical analysis, accessible through the on-screen menu.

Image: The multimeter interface showing voltage readings and measurement options.

Image: Multimeter probes, typically included as standard configuration for TO1000C/D Series.
4.3 Arbitrary Function Generator (AFG) Function
The AFG can generate various waveforms for testing purposes.
- From the home screen, tap the "AFG" icon.
- Connect the crocodile clips (or other appropriate cables) to the AFG output port.
- Select the desired waveform type (e.g., sine, square, triangle, arbitrary) and configure parameters such as frequency, amplitude, and offset using the touch screen controls.
- The device supports AM/FM modulation.

Image: The signal generator interface, showing options for waveform type, frequency, amplitude, and offset.

Image: Crocodile clips, typically included for signal generator output.
4.4 Touch Screen Operation
The device features a full touch screen for intuitive control:
- Tap: Select menu items, buttons, or input fields.
- Pinch-to-zoom: Adjust vertical and horizontal scales on the oscilloscope display.
- Drag: Move waveforms or adjust trigger levels.

Image: A hand demonstrating touch screen interaction to adjust a waveform on the Hantek TO1254C.
5. Maintenance
5.1 General Care
- Keep the device clean and dry. Avoid exposure to dust, moisture, and extreme temperatures.
- Clean the screen with a soft, lint-free cloth. Do not use abrasive cleaners or solvents.
- The device features anti-shock corners for durability, but avoid dropping it from excessive heights.
5.2 Battery Care
- To maximize battery life, avoid fully discharging the battery frequently.
- If storing the device for an extended period, charge it to about 50-70% and store it in a cool, dry place.
- The battery is removable; however, replacement should only be performed by qualified personnel.
5.3 Probe Care
- Handle probes carefully. Do not bend or twist cables excessively.
- Store probes in a clean, dry place, preferably in the provided instrument package.
- Regularly inspect probes for any signs of wear or damage.

Image: The instrument package for safe storage and transport of the Hantek TO1254C and its accessories.
6. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Device does not power on. | Battery is discharged. | Connect the device to the charger and allow it to charge for at least 30 minutes before attempting to power on again. |
| No waveform displayed on oscilloscope. | Probe not connected correctly or circuit not active. Incorrect trigger settings. | Ensure probes are securely connected to both the device and the circuit. Verify the circuit is powered. Adjust trigger level and mode. Check probe attenuation settings. |
| Multimeter readings are inaccurate. | Probes are faulty or incorrect measurement mode selected. | Check multimeter probes for damage. Ensure the correct measurement function (voltage, current, resistance) is selected for the parameter being measured. |
| Touch screen unresponsive. | Temporary software glitch or screen contamination. | Restart the device. Clean the screen with a soft, dry cloth. If the issue persists, contact support. |
7. Specifications
7.1 General Specifications
- Brand Name: Hantek
- Model Number: Hantek TO1254C
- HANTEK Model: TO1254C
- DIY Supplies: Electrical
- Certification: CE
- Origin: Mainland China
- Display Size: 5.0 - 6.9 Inches
- Display Resolution: 640*480 Pixels
- Battery Included: Yes
- IS Battery Demountable: Yes
- High-concerned chemical: None
7.2 Oscilloscope Specifications
| Parameter | TO1000 Series (1G Sampling) | TO1112 Series (250M Sampling) |
|---|---|---|
| Digital Channels | 4 | 2 |
| Band Width | 100-349MHz (TO1254C is 250MHz) | 110MHz |
| Real Time Sampling Rate | 1GSa/S | 250MSa/S |
| Max Waveform Capture Rate | 30,000wfm/s | N/A |
| Record Length | 8M | 8M |
| Horizontal Scale Range | 2ns/div~100s/div (1, 2, 5 sequence) | 2ns/div~100s/div (1, 2, 5 sequence) |
| A/D Converter | 8-bit resolution, each channel sampled simultaneously | 8-bit resolution, each channel sampled simultaneously |
| Vertical Scale Range | 2mV/div~10V/div at input BNC | 10mV/div~10V/div at input BNC |
| Vertical Resolution | 8bit | 8bit |
| Vertical Sensitivity Range | 2mV/div~10V/div | 10mV/div~10V/div |
| Offset Range | ±1V (2mV/div~100mV/div), ±10V (200mV/div~1V/div), ±50V (2V/div~10V/div) | ±1Vmax (100mV/div), ±10Vmax (1V/div), ±50Vmax (10V/div) |
| Dynamic Range | ±5div (8bit) | ±5div (8bit) |
| Optional Analog Bandwidth Limitation | 20MHz, each channel independently selectable | 20MHz, each channel independently selectable |
| DC Gain Accuracy | ±3% FullScale | ±3% FullScale |
| Isolation Between Channels | 40dB, DC to the maximum rated bandwidth of each model | 40dB, DC to the maximum rated bandwidth of each model |
| Note: Bandwidth reduced to 6MHz when using a 1X probe. | ||
| Acquisition Modes | Normal, Average, Peak, High resolution | Normal, Average, Peak, High resolution |
| Waveform Interpolation | (sinx)/x | (sinx)/x |

Image: A table detailing the oscilloscope specifications for TO1000 and TO1112 series.
7.3 Model Comparison
| Model | Oscilloscope channel | Bandwidth | Sampling Rate | Storage depth | Signal source (AFG) | Multimeter |
|---|---|---|---|---|---|---|
| TO1154D | 4 CH | 150 MHz | 1GSa/S | 8M | 25MHz | Yes |
| TO1204D | 4 CH | 200 MHz | 1GSa/S | 8M | 25MHz | Yes |
| TO1254D | 4 CH | 250 MHz | 1GSa/S | 8M | 25MHz | Yes |
| TO1112 | 2 CH | 110 MHz | 250MSa/S | 8M | - | - |
| TO1112C | 2 CH | 110 MHz | 250MSa/S | 8M | - | Yes |
| TO1112D | 2 CH | 110 MHz | 250MSa/S | 8M | 25MHz | Yes |

Image: A comparison table showing specifications for various models within the Hantek TO1000 series.
8. User Tips
- Optimize Battery Life: For prolonged field use, consider carrying a portable power bank compatible with Type-C fast charging to extend operational time.
- Screen Protection: While the screen is durable, applying a screen protector can further safeguard against scratches and impacts during heavy use.
- Probe Calibration: Periodically check and calibrate your oscilloscope probes to ensure accurate measurements, especially after significant temperature changes or rough handling.
- Software Updates: Check the official Hantek website for any firmware updates that might improve performance, add features, or fix bugs.
- Utilize Hanging Design: Take advantage of the unique hanging feet to position the device optimally, freeing your hands for probe manipulation or other tasks.
9. Warranty and Support
For warranty information, technical support, or service inquiries, please refer to the official Hantek website or contact your authorized dealer. Keep your purchase receipt as proof of purchase for warranty claims.