1. Important Safety Instructions
- Read all instructions before using the appliance.
- This appliance is for indoor use only.
- Ensure the power supply matches the unit's requirements (110V, 20A).
- Do not operate the unit with a damaged cord or plug.
- Keep the unit away from heat sources and direct sunlight.
- Ensure proper ventilation and do not block air inlets or outlets.
- Always unplug the unit before cleaning or servicing.
2. Product Overview
The Gree Aovia GPC12AP-A6NNA1A is a compact and efficient portable air conditioner designed to cool and dehumidify rooms between 12 to 18 square meters. It features a conventional compressor, R32 refrigerant, and user-friendly controls.

Figure 1: Front view of the Gree Aovia Portable Air Conditioner.

Figure 2: Rear view of the unit, highlighting the exhaust port and power cord management.
3. Setup and Installation
- Unpacking: Carefully remove the air conditioner from its packaging. Retain packaging materials for future storage or transport.
- Placement: Place the unit on a flat, stable surface. Ensure there is at least 20-30 cm (8-12 inches) of clear space around the unit for proper airflow. Do not place it near curtains or other objects that could obstruct air intake or exhaust.
- Window Kit Installation (if applicable): While specific window kit details are not provided, portable air conditioners typically require an exhaust hose to vent hot air outside.
- Attach the exhaust hose to the exhaust port on the rear of the unit (refer to Figure 2).
- Install the window sealing plate in a compatible window opening.
- Extend the exhaust hose through the opening in the window sealing plate, ensuring a tight seal to prevent hot air from re-entering the room.
- Power Connection: Ensure your electrical outlet is 110V and rated for 20A. Plug the power cord directly into a grounded wall outlet. Do not use extension cords or power strips.
- Initial Check: After setup, wait at least 2 hours before turning on the unit if it has been tilted during transport, to allow refrigerants to settle.
4. Operating Instructions
4.1 Control Panel and Remote Control
The unit can be operated via the digital display on the top panel or the included remote control. The digital display indicates the current operating mode, set temperature, and any protection codes.
4.2 Operating Modes
- Cooling Mode: Select this mode for active cooling. Adjust the desired temperature using the temperature up/down buttons. The unit will cool the room to the set temperature.
- Dehumidification Mode: This mode helps reduce humidity in the room without significant cooling.
- Fan Mode: The unit offers 3 ventilation options (low, medium, high). In this mode, the compressor does not run, and the unit circulates air.
4.3 Special Functions
- Fast Cooling: Activates maximum cooling power for rapid temperature reduction.
- Timer Function: Allows you to set a specific time for the unit to turn on or off automatically.
- Sleep Mode: Optimizes operation for quietness and energy efficiency during sleep, gradually adjusting the temperature.
- Swing Function: Activates the automatic oscillation of the air outlet louvers to distribute air more evenly.
5. Maintenance
Regular maintenance ensures optimal performance and longevity of your air conditioner.
- Air Filter Cleaning: The unit is equipped with a removable filter.
- Turn off and unplug the unit before cleaning.
- Remove the air filter (location typically on the back or side, refer to unit diagrams).
- Clean the filter with a vacuum cleaner or wash it gently with lukewarm water and mild detergent.
- Rinse thoroughly and allow it to air dry completely before reinstalling.
- Clean the filter every two weeks or more frequently depending on usage and air quality.
- Water Drainage: The unit features a dual-drain output. During dehumidification or cooling, water condensation will collect inside.
- When the internal water tank is full, the unit may stop operating and display a "full water" indicator.
- Place a shallow pan or connect a drain hose (if provided) to the drainage port (usually at the bottom rear of the unit).
- Remove the drain plug to allow water to flow out.
- Replace the drain plug securely once all water has drained.
- Exterior Cleaning: Wipe the exterior of the unit with a soft, damp cloth. Do not use harsh chemicals or abrasive cleaners.
- Storage: If storing the unit for an extended period, ensure it is completely drained of water, cleaned, and dried. Store it in a cool, dry place, preferably in its original packaging.
6. Troubleshooting
Before contacting support, please check the following common issues:
| Problem | Possible Cause | Solution |
|---|---|---|
| Unit does not turn on | No power; power cord unplugged; circuit breaker tripped; water tank full. | Check power connection; reset circuit breaker; drain water tank. |
| Unit not cooling effectively | Air filter dirty; room too large; windows/doors open; exhaust hose not properly installed; air intake/outlet blocked. | Clean air filter; ensure room size is within specifications; close windows/doors; check exhaust hose connection; clear obstructions. |
| Unit is noisy | Unit not on a flat surface; air filter dirty; internal components vibrating. | Place on a flat surface; clean air filter. If noise persists, contact support. |
| Water leakage | Drain plug loose or missing; unit tilted; drain hose (if used) blocked. | Ensure drain plug is secure; place unit on a level surface; check drain hose for kinks or blockages. |
| Digital display shows error/protection code | Internal fault; sensor issue; water tank full. | Refer to specific error codes in the full manual (if available) or contact support. Often, unplugging for a few minutes and plugging back in can reset minor errors. |
7. Specifications

Figure 3: Key specifications of the Gree Aovia Portable Air Conditioner.
| Feature | Detail |
|---|---|
| Brand | Gree |
| Model Number | GPC12AP-A6NNA1A |
| Type | Portable Air Conditioner |
| Cooling Capacity | 12,000 BTU/H |
| Recommended Room Size | 12 to 18 m² |
| Cycle | Cold |
| Compressor Technology | Conventional |
| Refrigerant Gas Type | R32 |
| Air-flow | 280 m³/H |
| Noise Level | 55/53/51 dB (A) |
| Serpentine Material | Copper (condenser) with Bluefin protection against corrosion and sea air |
| Material | ABS Plastic |
| Voltage | 110V (Not Bivolt) |
| Socket Type | 20A |
| Color | White |
| Product Weight | 22.5 kg |
| Product Dimensions (W x H x D) | 28.6 cm x 32 cm x 70 cm |
| Package Weight | 27 kg |
| Package Dimensions (W x H x D) | 39.6 cm x 33.1 cm x 87.6 cm |
| Inmetro Certificate Number | 3120220027500 |
8. User Tips
- Voltage Check: Always confirm your power outlet voltage matches the unit's 110V requirement. This unit is NOT dual voltage (bivolt).
- Room Sizing: For optimal cooling, ensure the room size is within the recommended 12 to 18 m² range. Using it in a larger room will reduce its effectiveness.
- Seal Exhaust: A well-sealed exhaust hose and window kit are crucial. Any gaps will allow hot air back into the room, reducing cooling efficiency.
- Regular Cleaning: Keep the air filter clean. A dirty filter restricts airflow, reduces cooling capacity, and increases energy consumption.
- Drain Regularly: In high humidity environments, the water tank will fill faster. Drain it promptly to avoid interruptions in operation.
9. Warranty and Support
This product comes with a 01-year warranty, which includes 3 months of legal warranty plus an additional 9 months of special warranty granted by the manufacturer.
For warranty claims, technical support, or service inquiries, please contact your original point of purchase or the Gree customer service department. Please have your model number (GPC12AP-A6NNA1A) and proof of purchase ready.