1. Introduction
The Hantek DPO6000/MPO6000 Series Digital Oscilloscopes are advanced instruments designed for precise waveform analysis. These oscilloscopes feature a high waveform capture rate of up to 400,000 FPS, a 256-grade color and color temperature display, and a comprehensive set of trigger and decoding functions. With bandwidths ranging from 80 MHz to 200 MHz and a memory depth of up to 64M, they are suitable for various applications in communication, aerospace, defense, embedded systems, computers, research, and education. MPO models also include a 16-channel logic analyzer, and all models are equipped with a 2-channel waveform generator and a touch screen for intuitive operation.

Figure 1: Front view of the Hantek DPO6000 series digital oscilloscope
2. Package Contents
Before proceeding with the setup, please verify that all items listed below are present in your package:
- Hantek DPO6000/MPO6000 Series Digital Oscilloscope Unit
- User Manual / Documentation
- USB Cable
- Power Cable
- Oscilloscope Probes (x4)

Figure 2: Packaging Accessories
3. Setup Instructions
3.1 Power Connection
- Ensure the oscilloscope is placed on a stable, flat surface with adequate ventilation.
- Connect the provided power cable to the power input port on the rear panel of the oscilloscope.
- Plug the other end of the power cable into a suitable AC power outlet (100-240V, 45-440Hz, 60W MAX).
- Press the power button on the front panel to turn on the device.

Figure 3: Rear panel with power input and warning label
3.2 Probe Connection
- Connect the BNC end of the oscilloscope probes to the input channels (CH1, CH2, CH3, CH4) on the front panel.
- Ensure a secure connection by twisting the BNC connector until it locks.
- Attach the probe tip to the circuit point you wish to measure.
- For accurate measurements, perform probe compensation as described in the operating section.
3.3 USB Connection
The oscilloscope features a USB 2.0 interface for plug-and-play connectivity without external power supply. This allows for data transfer and control via a computer.

Figure 4: USB interface and signal connections
4. Operating Instructions
4.1 Basic Operation
The DPO6000/MPO6000 series features a large 7-inch 64K color TFT true color LCD with 800x480 resolution and a touch screen for user-friendly operation. Navigate through menus and adjust settings using the touch interface or the physical control knobs and buttons.

Figure 5: Large screen and user-friendly operation interface
4.2 Key Features
- Waveform Capture Rate: Up to 400,000 frames per second (FPS) for capturing transient events.
- Display: 256-grade color and color temperature display for enhanced waveform visualization.
- Trigger Functions: Standard equipped with up to 16 types of trigger functions for precise signal isolation.
- Serial Decoding: Includes 5 types of serial decoding functions for analyzing serial bus communications.
- Logic Analyzer (MPO Models): 16-channel logic analyzer for mixed-signal analysis.
- Waveform Generator: Integrated 2-channel waveform generator for signal injection and testing.
- Multi-function Tester: Capable of various measurements including digital voltmeter, serial protocol analysis, and FFT spectrum analysis.

Figure 6: Six-in-one oscilloscope capabilities
4.3 Video Overview
Video 1: A brief overview of the Hantek DPO6000/MPO6000 series oscilloscope features and functions.
5. Specifications
5.1 General Specifications
| Attribute | Value |
|---|---|
| Brand Name | Hantek |
| Model Number | DPO6082C/DPO6084C/DPO6102C DPO6104C/DPO6202C/DPO6204C |
| DIY Supplies | Electrical |
| Certification | CE |
| Origin | Mainland China |
| Display Size | 7 Inches & Above |
| Display Resolution | 640*480 Pixels |
| Battery Included | No |
| IS Battery Demountable | Yes |
| High-concerned chemical | None |
5.2 Oscilloscope Performance Specifications
| Feature | Specification |
|---|---|
| Number of Channels | 4 Digital Channels |
| Bandwidth | 80MHz (DPO6084C/MPO6084D), 100MHz (DPO6104C/MPO6104D), 200MHz (DPO6204C/MPO6204D) |
| Real Time Sampling Rate | 1GSa/S |
| Max Waveform Capture Rate | 30,000wfm/s (60,000/400,000 for DPO/MPO models) |
| Record Length | 64M (single channel), 32M (dual channel), 16M (three/four channel), 8M (five/six channels) |
| Vertical Resolution | 500uV~10V (Analog channel 8bit, Digital channel 1bit) |
| Touch Screen | Yes |
| Peak Detection | Analog channel 4ns (Digital channel not supported) |
| Average Mode | Analog channel, N times sampling (2, 4, 8, 16, 32, 64, 128, 256, 512, 1024) (Digital channel not supported) |
| High Resolution | Up to 12bit (Digital channel not supported) |
| Minimum Detection Pulse Width | 8ns |
| Input Coupling | DC, AC or GND (Digital channel does not support) |
| Input Impedance, DC coupling | Analog channel: 25pF±3 pF, 1MΩ±2%; Digital channel: (300KΩ±2%), (8 pF±3 pF) |
| Support Probe Attenuation Coefficient | Analog channels 1X, 10X, 100X, 1000X |
| Voltage Level | 300V CAT II |
| Maximum Input Voltage | Analog channel 300VRMS (10X); Digital channel -25V~25V |
| Waveform Interpolation | (sin x)/x |
| Horizontal Scale Range | 2ns/div~100s/div (1, 2, 5 steps) |
| Time Base Mode | Y-T, X-Y, Roll |
| Number of X-Y | 1-2 channels: 1 XY channel; 3-4 channels: 1 XY channel |
| Zero Shift | ±0.5 div × Minimum base gear |
| Sampling Rate and Delay Time Accuracy | ±25ppm |
| Clock Drift | ≤± 5 ppm/year |
| Incremental Time Measurement Accuracy (Single time, "sampling" mode) | ± (1 sampling interval+100ppm × Reading+0.6ns) |
| Incremental Time Measurement Accuracy (Average of more than 16 times) | ± (1 sampling interval+100ppm × Reading+0.4 ns) |
| Sampling Interval | seconds/division ÷ 200 |
| Optional Analog Bandwidth Limitation | Typical 20MHz |
| Low Frequency Response (-3db) | ≤ 10Hz at BNC |
| Rise Time at BNC (typical) | DPO6084: ≤4.4ns; DPO6104: <3.5ns; DPO6204: ≤1.8ns |
| Vertical Gain Accuracy | ± 3% (10V/grid to 10mV/grid); ± 4% (5mV/grid to 500uV/grid) in "normal" or "average" acquisition mode. |
| DC Offset Accuracy | ± 0.1 div ± 2 mV ± 1% offset value |
| Channel Isolation | DC to maximum bandwidth: >40 dB |
Note: When using X1 probe, the bandwidth is reduced to 6MHz.
6. Maintenance
6.1 General Care
- Keep the oscilloscope clean and free from dust. Use a soft, dry cloth for cleaning the exterior.
- Avoid exposing the device to extreme temperatures, humidity, or direct sunlight.
- Do not use abrasive cleaners or solvents that could damage the casing or screen.
6.2 Heat Dissipation
The oscilloscope is designed with high-efficiency heat dissipation through cooling holes located on the body top, side, and rear of the fuselage. Ensure these vents are not obstructed during operation to prevent overheating.

Figure 7: All directional heat dissipation design
6.3 Safety Warning
WARNING: Hazardous voltage inside. Do not remove the cover unless by specified personnel.
7. Troubleshooting
If you encounter any issues with your Hantek oscilloscope, please refer to the following general troubleshooting steps:
- No Power: Check the power cable connection and ensure the power outlet is functional. Verify the power button is pressed.
- No Signal Display: Ensure probes are correctly connected to both the oscilloscope and the circuit under test. Check probe settings (e.g., 1X/10X attenuation) and channel input coupling (AC/DC/GND).
- Unstable Waveform: Adjust trigger settings (level, mode, source) to stabilize the waveform. Check for proper grounding.
- Incorrect Measurements: Verify probe compensation is correctly performed. Ensure the vertical and horizontal scales are set appropriately for the signal being measured.
- Software/Connectivity Issues: If using with a computer, ensure the correct drivers are installed and the USB connection is secure. Try restarting both the oscilloscope and the computer.
For more detailed troubleshooting or persistent issues, please contact Hantek customer support.
8. User Tips
- Probe Compensation: Always perform probe compensation when using new probes or if you suspect measurement inaccuracies. This ensures the probe's frequency response is flat.
- Grounding: Proper grounding is crucial for accurate and safe measurements. Always connect the probe's ground clip to the circuit's ground reference.
- Firmware Updates: Check the official Hantek website periodically for firmware updates to ensure your device has the latest features and bug fixes.
- Explore Trigger Modes: Experiment with different trigger modes (Edge, Pulse, Video, Slope, etc.) to effectively capture and analyze various types of signals, especially complex or intermittent ones.
- Utilize Advanced Functions: Don't hesitate to explore the built-in logic analyzer (MPO models), waveform generator, serial decoding, and FFT spectrum analysis features to maximize the utility of your oscilloscope for diverse applications.
9. Warranty and Support
Hantek provides after-sell service for a period of 1 year from the date of purchase. For any service inquiries or technical support, please contact your vendor or Hantek directly. Please retain your proof of purchase for warranty claims.