1. Introduction
The Hantek 6104BC is a high-performance PC USB Oscilloscope designed for a wide range of electrical engineering applications. This device offers capabilities comparable to benchtop oscilloscopes, featuring 4 independent analog channels, a 1GSa/s real-time sampling rate, 2mV-10V/DIV input sensitivity, and a 100MHz bandwidth. Its compact size and USB 2.0 interface make it a portable and convenient tool for professionals and hobbyists alike.
This manual provides essential information for setting up, operating, maintaining, and troubleshooting your Hantek 6104BC oscilloscope.
Product Overview Video
This video provides a visual overview of the Hantek 6104BC PC USB Oscilloscope and its features.
Key Features
- 4 independent analog channels with 1GSa/s real-time sampling rate.
- 100MHz bandwidth and 2mV-10V/DIV input sensitivity.
- USB 2.0 interface for plug-and-play connectivity.
- Compact and portable design with an anodized aluminum casing for durability and heat resistance.
- Pass/fail test functionality and resourceful trigger functions (Edge, Pulse, Video, Alternative).
- Dynamic cursor tracking, waveform record and replay.
- Software support for Windows 7, Windows 8, and Windows 10.
- Waveform data output to EXCEL, BMP, JPG formats.
- Over 20 types of automatic measurement functions.
- Waveform averaging, afterglow, lightness control, reverse, add, subtract, multiply, divide, X-Y display.
- Integrated FFT spectrum analyzer.
- Ability to connect multiple oscilloscopes to one computer to expand channel count.
- USBXI standard interface for assembling instruments.
- Secondary development library (DLL) and examples for Labview, VB, VC.
2. Package Contents
Please verify that all items listed below are included in your package:
- 1 x Hantek 6104BC PC USB Digital Storage Oscilloscope
- 2 x Dolphin/Gator Clip Cables
- 2 x Oscilloscope Probes (PP-150 for 100MHz model)
- 1 x USB Power Line
- 1 x Upper-computer Software CD with User Manual

Image: Contents of the Hantek 6104BC package, including the oscilloscope unit, probes, clip cables, USB cable, and software CD.
3. Setup Guide
- Unpack the Device: Carefully remove the Hantek 6104BC oscilloscope and all accessories from its packaging.
- Connect to Computer: Connect the oscilloscope to your computer using the provided USB power line. The device utilizes a USB 2.0 interface for both data transfer and power.
- Software Installation:
- Insert the included software CD into your computer's CD-ROM drive.
- Follow the on-screen instructions to install the Hantek oscilloscope software and necessary drivers.
- Alternatively, if your computer does not have a CD drive or for the latest version, download the software from the official Hantek website.
The software supports Windows 7, Windows 8, and Windows 10 operating systems.
- Connect Probes: Attach the oscilloscope probes to the BNC connectors on the front panel of the Hantek 6104BC. Ensure a secure connection.
- Power On: Once connected and software is installed, the device is ready for use. The oscilloscope is a plug-and-play device.

Image: The Hantek 6104BC oscilloscope connected to a tablet, demonstrating its use with a PC interface for waveform display and analysis.
4. Operating Instructions
The Hantek 6104BC oscilloscope software provides an intuitive interface similar to traditional benchtop oscilloscopes. Familiarize yourself with the software layout and controls for effective operation.
Basic Operation
- Launching Software: Double-click the Hantek oscilloscope software icon on your desktop to launch the application.
- Channel Selection: Select the desired analog channels (CH1, CH2, CH3, CH4) for measurement within the software interface.
- Input Sensitivity: Adjust the input sensitivity (2mV/div to 10V/div) to match the amplitude of the signal being measured.
- Time Base Adjustment: Set the time base range (2ns/div to 1000s/div) to capture the desired duration of the waveform.
- Trigger Settings: Configure the trigger mode (Edge, Pulse, Video, Alternative) and trigger source (CH1, CH2, CH3, CH4) to stabilize the waveform display.
Advanced Functions
- Automatic Measurements: Utilize the software's automatic measurement functions for parameters such as Vpp, Vamp, Vmax, Vmin, Vtop, Vmid, Vbase, Vavg, Vrms, Vcrms, Preshoot, Overshoot, Frequency, Period, Rise Time, Fall Time, Positive Width, Negative Width, and Duty Cycle.
- Cursor Measurements: Use cross, trace, horizontal, and vertical cursors for precise manual measurements.
- Waveform Processing: Apply waveform signal processes including addition, subtraction, multiplication, division, FFT (Fast Fourier Transform), and inversion.
- Pass/Fail Test: Configure pass/fail criteria to automatically check if waveforms meet specified limits, suitable for production line testing.
- Waveform Recording and Replay: Record and replay waveforms for detailed analysis and comparison.
- Data Export: Export waveform data to common formats like EXCEL, BMP, and JPG for documentation and further analysis.

Image: Front view of the Hantek 6104BC oscilloscope, showing the four BNC input connectors.
5. Technical Specifications
Below are the detailed technical specifications for the Hantek 6104BC PC USB Oscilloscope:
| Parameter | Specification |
|---|---|
| Model | Hantek6104BC |
| Bandwidth | 100MHz |
| Digital Channels | 4 CH |
| Real-time Sampling Rate | 1GSa/s |
| Memory Depth | 64K |
| Time Base Precision | ±50ppm |
| Time Base Range | 2ns/div-1000s/div (1-2-4 sequences) |
| Input Impedance | 1MΩ 25pF |
| Input Sensitivity | 2mV/div~10V/div |
| Vertical Resolution | 8Bit |
| Vertical Displacement Range | 2mV ~ 10V/div @ x1 probe; 20mV ~ 100V/div @ x10 probe; 200mV ~ 1000V/div @ x100 probe; 2V ~ 10000V/div @ x1000 probe |
| DC Gain Accuracy | ±3% |
| Trigger Bandwidth | 20MHz |
| Trigger Mode | Edge, Pulse, Video, Alternative |
| Trigger Source | CH1, CH2, CH3, CH4 |
| Waveform Signal Process | +,-,x,÷,FFT, Invert |
| Cursors Measurement | Cross, Trace, Horizontal, Vertical |
| Auto Measurement | Vpp, Vamp, Vmax, Vmin, Vtop, Vmid, Vbase, Vavg, Vrms, Vcrms, Preshoot, Overshoot, Frequency, Period, Rise Time, Fall Time, Positive Width, Negative Width, Duty Cycle |
| Dimensions (Volume) | 210mm x 125mm x 37mm |
| Weight | 0.46KG |
| DIY Supplies | Electrical |
| Origin | Mainland China |
| Certification | CE |
| Battery Included | No |
| IS Battery Demountable | No |
| High-concerned chemical | None |

Image: A table summarizing the technical specifications for the Hantek 6074BC and 6104BC models, including bandwidth, sampling rate, and input sensitivity.
6. Care and Maintenance
To ensure the longevity and optimal performance of your Hantek 6104BC oscilloscope, follow these maintenance guidelines:
- Cleaning: The outer casing is made of anodized aluminum, which offers good heat and abrasive resistance. Clean the exterior with a soft, dry cloth. For stubborn dirt, a slightly damp cloth can be used, but ensure no moisture enters the device. Avoid using harsh chemicals or abrasive cleaners.
- Storage: Store the oscilloscope in a cool, dry place away from direct sunlight, extreme temperatures, and high humidity. When not in use, it is recommended to store it in its original packaging or a protective case.
- Handling: Handle the device with care to prevent physical damage. Avoid dropping or subjecting it to strong impacts.
- Probe Care: Keep the oscilloscope probes clean and free from dust or debris. Store them properly to prevent bending or damage to the tips.
- Software Updates: Regularly check the official Hantek website for software and driver updates to ensure compatibility and access to the latest features and bug fixes.
7. Troubleshooting
If you encounter issues with your Hantek 6104BC oscilloscope, please refer to the following common troubleshooting steps:
- Device Not Recognized:
- Ensure the USB cable is securely connected to both the oscilloscope and your computer.
- Try connecting to a different USB port on your computer.
- Verify that the necessary drivers are correctly installed. Reinstall the software if needed.
- Test the oscilloscope on another computer to rule out computer-specific issues.
- No Waveform Display:
- Check that the oscilloscope probes are properly connected to the device and the circuit under test.
- Ensure the input signal is within the oscilloscope's voltage range. Adjust the input sensitivity if necessary.
- Verify that the trigger settings are correctly configured. An unstable trigger can result in a blank or erratic display.
- Confirm that the correct channels are enabled in the software.
- Software Crashes or Freezes:
- Ensure your operating system (Windows 7, 8, or 10) is up to date.
- Close other demanding applications running on your computer.
- Reinstall the Hantek software.
- Check for the latest software version on the Hantek website.
If these steps do not resolve your issue, please contact customer support for further assistance.
8. User Tips
While no specific user tips were available from reviews or Q&A, here are some general recommendations for optimizing your experience with the Hantek 6104BC oscilloscope:
- Probe Calibration: Periodically calibrate your oscilloscope probes to ensure accurate measurements. Refer to the software's calibration utility or the detailed user manual on the provided CD for instructions.
- Grounding: Always ensure proper grounding of your oscilloscope and the circuit under test to prevent noise and ensure safety.
- Software Exploration: Take time to explore all features and settings within the Hantek software. Many advanced analysis tools can significantly enhance your measurement capabilities.
- Environmental Conditions: Operate the oscilloscope within its specified environmental conditions (temperature, humidity) to maintain performance and prevent damage.
9. Warranty and Support
Hantek provides after-sales service for this product. Please refer to the following information regarding warranty and support:
- Warranty Period: The product comes with a 1-year after-sales service from the date of purchase.
- Service Coverage: During the warranty period, the manufacturer will cover one-way freight for service (from China to your location).
- Defective Parts: In case of missing or defective parts, notify the seller no later than 5 days after receiving the item for re-shipment arrangements.
- Exchanges: For exchanges, the buyer must email an exchange notice prior to returning the item and will bear the freight and handling fees.
- Contact Support: For any technical issues, warranty claims, or support inquiries, please contact the seller or Hantek customer service directly. Refer to the contact information provided with your purchase or on the official Hantek website.

Image: Details of the After Service Policy, outlining warranty and exchange procedures.