1. Introduction
The EARU EAL-1 series is a high-performance Electronic Residual Current Circuit Breaker (RCBO/RCCB/MCB) designed to provide comprehensive protection against leakage current, overload, and short circuits in electrical systems. This device is suitable for various applications, including household lighting distribution boxes and EV charging circuits. It is available in Type AC, Type A, and Type B to cater to different types of leakage current detection requirements.
Key Features:
- Leakage protection
- Overload protection
- Short circuit protection
- 2-pole configuration
- Rated Voltage: 230V~ 50/60Hz
- Mechanical lifespan: 20,000 cycles
- CE Certified, compliant with IEC/EN61009-1 and GB16917.1 standards
- Rail-mounted installation
- PC flame retardant material for enhanced safety

Figure 1: Overview of EARU EAL-1 Circuit Breaker (Type A, Type B, Type AC)
2. Safety Information
WARNING: Installation and maintenance should only be performed by qualified electricians in accordance with local electrical codes and regulations. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Always disconnect power before installing or servicing the circuit breaker.
- Ensure proper grounding.
- Do not operate the device if it appears damaged.
- Verify correct wiring connections to prevent malfunction.
- The device is designed for specific current and voltage ratings; do not exceed these limits.
3. Setup and Installation
The EARU EAL-1 circuit breaker is designed for 35mm standard rail installation, making it suitable for direct mounting in household lighting distribution boxes.
3.1 Component Identification

Figure 2: Component Identification and Basic Wiring Diagram
- Wiring Terminal (1, 2, N): Points for connecting live (L) and neutral (N) wires.
- Leakage Value: Indicates the residual current sensitivity (e.g., 30mA).
- Function Model: Specifies the type (e.g., Type A, Type B, Type AC).
- Test Button (T): Used for monthly functional testing.
- Wiring Diagram: Illustrates internal connections.
- Rated Voltage: Operating voltage (e.g., 230V~).
- Breaking Capacity: Maximum fault current the breaker can safely interrupt (e.g., 6000A).
- Visible Window: Indicator for circuit status (Green: Breaker open/circuit stops running; Red: Circuit breaker closed/circuit operating normally).
- Rated Current: Maximum continuous current (e.g., C40 for 40A).
- T-type Operating Handle: Lever to manually switch the breaker ON/OFF.
3.2 Mounting
The circuit breaker features a fixed buckle for easy rail-mounted installation. Simply align the device with the 35mm DIN rail and press firmly until it clicks into place.

Figure 3: Example of 35MM Standard Rail Installation
3.3 Wiring Connections
Connect the live (L) and neutral (N) wires to the designated wiring terminals. The terminals are fixed with screws for secure connections. Ensure all connections are tight to prevent loose contacts and overheating.

Figure 4: Close-up of Wiring Terminals and Visualization Window
Wire Selection Guide:
| Rated Current | Copper Core Wire (mm²) | Load Power (W) | Practical Scenarios |
|---|---|---|---|
| 1-5A | <1mm | <1100w | Small power equipment |
| 6A | ≥1mm | ≤1320w | Lighting |
| 10A | ≥1.5mm | ≤2200w | Lighting |
| 16A | ≥2.5mm | ≤3520w | Lighting socket |
| 20A | ≥2.5mm | ≤4400w | Bedroom socket |
| 25A | ≥4mm | ≤5500w | Kitchen and bathroom sockets |
| 32A | ≥6mm | ≤7040w | Kitchen and bathroom sockets |
| 40A | ≥10mm | ≤8800w | Power main switch |
| 50A | ≥10mm | ≤11000w | Power main switch |
| 63A | ≥16mm | ≤13200w | Power main switch |
| 80A | ≥16mm | ≤17600w | Power main switch |
| 100A | ≥25mm | ≤22000w | Power main switch |
| 125A | ≥35mm | ≤27500w | Power main switch |
Table 1: Recommended Copper Wire Sizes based on Rated Current and Load Power. This list is for reference only. Please choose the specific model based on the size of the house and the power consumption of the household appliances.
4. Operating Instructions
4.1 Turning On/Off
- To turn the circuit ON, push the T-type operating handle UP. The visible window will show RED, indicating the circuit is closed and operating normally.
- To turn the circuit OFF, push the T-type operating handle DOWN. The visible window will show GREEN, indicating the breaker is open and the circuit has stopped running.

Figure 5: Window Indicator showing ON (Red) and OFF (Green) states.
4.2 Understanding Different Types (AC, A, B)
The EAL-1 series offers different types of leakage protection:
- Type AC: Provides protection against AC leakage current only. It does not respond to pulsating DC leakage current.
- Type A: Protects against AC leakage current and also pulsating DC leakage current.
- Type B: Builds upon Type A, emphasizing additional protection against smooth DC residual current. This type is often recommended for applications like EV chargers.

Figure 6: Visual comparison and description of Type AC, Type A, and Type B.
Video 1: Demonstration of the circuit breaker's operation, including switching on/off and using the test button.
5. Maintenance
5.1 Monthly Test
To ensure the leakage protection function is working correctly, press the 'Test Monthly' button (marked 'T') on the front of the circuit breaker once a month. The breaker should trip immediately. If it does not trip, the device may be faulty and should be replaced by a qualified electrician.
5.2 Cleaning
Keep the circuit breaker clean and free from dust and debris. Use a dry, soft cloth for cleaning. Do not use liquid cleaners or solvents.
6. Troubleshooting
If the circuit breaker trips, it indicates a fault condition (leakage, overload, or short circuit). Follow these steps:
- Identify the Cause: Disconnect all appliances or loads connected to the circuit.
- Reset the Breaker: Push the operating handle fully to the OFF position (down), then back to the ON position (up).
- Test the Circuit: If the breaker holds, reconnect appliances one by one to identify the faulty device or wiring section.
- Persistent Tripping: If the breaker trips immediately after resetting, or if it trips frequently, there is a persistent fault in the wiring or an appliance. Consult a qualified electrician for inspection and repair.
- Test Button Failure: If the 'Test Monthly' button does not trip the breaker, the device is faulty and must be replaced.
7. Specifications
| Parameter | Value |
|---|---|
| Product Series | EAL-1 |
| Product Type | AC/A/B type |
| Rated Voltage | 230V~ 50/60Hz |
| Rated Current Options | 6/10/16/20/25/32/40/50/63A |
| Leakage Value Options | 10/30/100/300mA |
| Mechanical Lifespan | 20,000 cycles |
| Mounting | 35mm DIN rail mounted |
| Product Certification | CE |
| Standard | IEC/EN61009-1 GB16917.1 |
| Rated Short-Circuit Capacity | 6000A |
| Product Function | Overload/Short Circuit/Leakage Protection |
| Is Smart Device | No |
| High-concerned chemical | None |

Figure 7: Product Dimensions and Detailed Parameters
8. User Tips
- Correct Type Selection: For EV charging applications, consider using a Type B RCBO for enhanced protection against smooth DC residual currents.
- Regular Testing: Make the monthly test a routine to ensure the leakage protection mechanism is always functional.
- Professional Installation: Always have the circuit breaker installed by a certified electrician to guarantee safety and compliance.
- Wire Gauge: Refer to the wire selection guide (Table 1) to ensure appropriate wire thickness for your rated current to prevent overheating and ensure optimal performance.