Daxtromn GGH-6.5KVA-PARALLEL

Contents

Daxtromn GGH-6.5KVA-PARALLEL Hybrid Parallel Solar Inverter Instruction Manual

Model: GGH-6.5KVA-PARALLEL

1. Product Overview

The Daxtromn GGH-6.5KVA-PARALLEL is a high-performance 6.5kVA 48V hybrid parallel solar inverter, designed to provide reliable power with a 5500W pure sine wave output. It features an 80A MPPT solar charger and can be paralleled to create systems up to 33kW, supporting both single and three-phase configurations. This inverter is built for efficient energy conversion, safety, and stability, making it suitable for various solar power applications.

Key Features:

  • Rated Power: 6500VA/5500W
  • Pure Sine Wave Output
  • 80A MPPT Solar Charger
  • Parallel Capability: Up to 6 units for 33kW total power (single or three-phase)
  • Max PV Input: 450VDC
  • Max 48V DC Charger: 400A (for 33kW system)
  • Built-in Parallel Card (no additional card required)
  • Supports Lithium, Lead-Acid, and Gel Batteries
  • BMS Protocol Support: PYLON or PACE
  • Wall-mounted design for easy installation
  • LED display and control panel
  • High efficiency (up to 93.6%)
  • AC/DC lightning protection
  • Adaptive support for lithium batteries
  • Optional WiFi remote monitoring
  • Durable stainless steel shell with baking varnish process
  • Adaptive to low-temperature environments with heating plate
Daxtromn 6.5kVA Hybrid Parallel Solar Inverter
Image: Daxtromn 6.5kVA Hybrid Parallel Solar Inverter unit.
Internal view of the Daxtromn inverter highlighting components like LED display, control panel, BMS, heating plate, and stainless steel shell.
Image: Internal view of the Daxtromn inverter highlighting key components and features such as the LED display, control panel, BMS, heating plate, and stainless steel shell, emphasizing efficient conversion, safety, and stability.

2. Setup and Installation

2.1 Physical Installation

The inverter is designed for wall-mounted installation. Ensure a secure mounting location with adequate ventilation for optimal heat dissipation. The unit features a high-quality heating pane and fast heat dissipation mechanisms, but proper airflow is still crucial.

2.2 Parallel Combination (for multi-unit systems)

The GGH-6.5KVA-PARALLEL inverter has a built-in parallel card, simplifying multi-unit installations. No additional parallel cards are required. Follow the instructions below for connecting multiple units to achieve higher power outputs.

General Link Instructions:

General wiring diagram for Daxtromn hybrid solar inverter showing connections to solar panels, generator, utility grid, wind turbine, and various AC/DC loads. It also illustrates parallel connection of multiple inverters.
Image: General wiring diagram for the Daxtromn hybrid solar inverter, illustrating connections to solar panels, a generator, utility grid, wind turbine, and various AC/DC loads. It also shows how multiple inverters can be connected in parallel for increased capacity.

Specific Parallel Configurations:

  • 5.5KW System: Single GGH-6.5KVA unit.
    Diagram showing a single 5.5kW inverter unit, with an 80A Max 48V DC Charger.
    Image: Single GGH-6.5KVA unit (5.5kW), with a maximum 80A 48V DC charger capacity.
  • 11KW System: Composed of 2 GGH-6.5KVA units in parallel.
    Diagram showing two 5.5kW inverters connected in parallel to form an 11kW 48V system, with a 160A Max 48V DC Charger.
    Image: Two GGH-6.5KVA units (5.5kW each) connected in parallel to achieve an 11kW 48V system, with a maximum 160A 48V DC charger capacity.
  • 16.5KW System: Composed of 3 GGH-6.5KVA units in parallel.
    Diagram showing three 5.5kW inverters connected in parallel to form a 16.5kW 48V system, with a 240A Max 48V DC Charger.
    Image: Three GGH-6.5KVA units (5.5kW each) connected in parallel to achieve a 16.5kW 48V system, with a maximum 240A 48V DC charger capacity.
  • 22KW System: Composed of 4 GGH-6.5KVA units in parallel.
    Diagram showing four 5.5kW inverters connected in parallel to form a 22kW 48V system, with a 320A Max 48V DC Charger.
    Image: Four GGH-6.5KVA units (5.5kW each) connected in parallel to achieve a 22kW 48V system, with a maximum 320A 48V DC charger capacity.
  • 27.5KW System: Composed of 5 GGH-6.5KVA units in parallel.
    Diagram showing five 5.5kW inverters connected in parallel to form a 27.5kW 48V system, with a 400A Max 48V DC Charger.
    Image: Five GGH-6.5KVA units (5.5kW each) connected in parallel to achieve a 27.5kW 48V system, with a maximum 400A 48V DC charger capacity.
  • 33KW System: Composed of 6 GGH-6.5KVA units in parallel.
    Diagram showing six 5.5kW inverters connected in parallel to form a 33kW 48V system, with a 400A Max 48V DC Charger.
    Image: Six GGH-6.5KVA units (5.5kW each) connected in parallel to achieve a 33kW 48V system, with a maximum 400A 48V DC charger capacity.

2.3 Electrical Connections

Refer to the "General Link Instructions" diagram for detailed electrical connections including solar panels, generator, utility grid, wind turbine, and various AC/DC loads. Ensure all connections are secure and comply with local electrical codes.

The inverter supports a maximum DC photovoltaic input of 500VDC and has a maximum battery charging current of 80A per unit.

3. Operation

The inverter features an intuitive LED display and control panel for monitoring and configuration. It provides a pure sine wave output, ensuring compatibility with sensitive electronics.

3.1 Battery Compatibility

The inverter supports various battery types, including lithium, lead-acid, and gel batteries. It employs an adaptive charging strategy for lithium batteries and a three-stage charging curve for optimal battery health. The external battery voltage required is 48V.

3.2 BMS Protocol Support

For advanced battery management, the inverter supports PYLON or PACE BMS protocols.

3.3 Grid Connection

Please note that this inverter does not support supplying power to the grid.

3.4 Remote Monitoring (Optional)

The inverter supports WiFi for remote monitoring. A WiFi module is not included in the standard package and must be purchased separately if remote monitoring functionality is desired.

4. Maintenance

To ensure the longevity and optimal performance of your Daxtromn inverter, regular maintenance is recommended:

  • Keep the inverter clean and free from dust and debris.
  • Ensure that the ventilation openings are unobstructed to allow for proper heat dissipation.
  • Periodically check all electrical connections for tightness and signs of wear or corrosion.
  • Inspect cables for any damage.
  • If operating in a low-temperature environment, ensure the heating plate is functioning correctly.

5. Troubleshooting

This section provides general troubleshooting tips. For specific error codes or complex issues, please refer to the detailed user manual (if available) or contact customer support.

  • No Power Output: Check AC input, battery connections, and ensure the inverter is turned on. Verify circuit breakers are not tripped.
  • Low Efficiency: Ensure solar panels are clean and optimally angled. Check battery health and connections.
  • Overheating: Ensure adequate ventilation around the unit. Clear any obstructions from cooling vents. Reduce load if continuously operating at maximum capacity in high ambient temperatures.
  • Battery Not Charging: Verify solar panel connections and output. Check MPPT settings and battery type configuration.

If issues persist, please contact Daxtromn customer support for assistance.

6. Specifications

Detailed specifications for the Daxtromn GGH-6.5KVA-PARALLEL Hybrid Parallel Solar Inverter:

Table of specifications for Daxtromn GGH-6.5KVA-PARALLEL inverter, including rated power, input/output AC voltage, surge power, efficiency, battery details, solar charge parameters, and general data.
Image: Comprehensive specifications table for the GGH-6.5KVA-PARALLEL inverter.
Category Parameter Value
Model & Power Model GGH-6.5KVA-Parallel
Rated Power 6500VA/5500W
Parallel Capability Yes
Work without Battery Yes
Input (AC) Voltage 230VAC
Optional Voltage Range 170-280VAC (For Personal Computers), 90-280VAC (For Home Appliances)
Frequency Range 50Hz/60Hz (Auto Sensing)
Output (AC) AC stabilized power 230VAC ±5%
Surge Power 11000VA
Peak efficiency 93.50%
Switching time 10ms (For Personal Computers); 20ms (For Home Appliances)
Wave form Pure Sine Wave
Battery Battery voltage range 42-60V
Charging curve Three-Stage
Lithium battery charging strategy Adaptive to lithium battery
Solar Charge & AC Charge Maximum photovoltaic power 5500W
Maximum PV open circuit voltage 500VDC
MPPT Range & Working Voltage 120-450VDC
Maximum Solar Charging Current 80A
Maximum AC Charging Current 60A
Solar Charger Type MPPT
General Data Product size(mm) 302*490*110
Package size(mm) 346*536*178
Net Weight(kgs) 9.7
Communication interface RS232/RS485CAN/Drycontact
Relative Humidity 5% to 95%
Operating Temperature -10°C to 50°C
Storage Temperature -15°C to 60°C
Certification Certification CE

7. Warranty and Support

The Daxtromn GGH-6.5KVA-PARALLEL Hybrid Parallel Solar Inverter comes with a 1-year warranty.

Customer Support:

  • For technical assistance, troubleshooting, or warranty claims, please contact Daxtromn customer support.
  • AliExpress offers "Fast delivery & get refunds for any issues" and "Free returns within 15 days" for eligible purchases. Refer to AliExpress terms for details.

For any questions regarding WiFi module purchase or other inquiries, please reach out to the seller.

© 2023 Daxtromn. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.