1. Introduction
The YIERYI Digital Soil Meter is a versatile tool designed to help you understand and optimize your plant's growing environment. Depending on the model, it can measure various parameters including soil pH, moisture, fertility, light intensity, soil temperature, ambient temperature, air humidity, EC (Electrical Conductivity), and salt levels. This manual provides detailed instructions for the setup, operation, maintenance, and troubleshooting of your soil tester.
2. What's in the Box
The contents of your package may vary slightly depending on the specific model purchased. Please refer to the packing list for your model in the Specifications section.

3. Specifications
This section details the specifications for various models of the YIERYI Digital Soil Meter.
3.1. YY-1066L Specification
| Parameter | Value |
|---|---|
| Model | YY-1066L |
| Name | 7-in-1 Soil Tester |
| Light | LOW-, LOW, NOR, HGH, HGH+ |
| Soil moisture | DRY-, DRY, NOR, WET, WET+ |
| Soil fertility | 1-99% |
| Soil PH | 3-8.5pH |
| Soil temperature | -10 ~ 60°C; 14 ~ 140°F |
| Air humidity | 1 ~ 100% |
| Ambient temperature | -10 ~ 60°C; 14 ~ 140°F |
| Display | LCD Large Display |
| Auto Power Off | 5 minutes |
| Battery | 3 * AAA Battery (Not included) |
3.2. YY-1088G/YY1088 Specifications
| Parameter | Range/Resolution/Accuracy |
|---|---|
| PH measuring range | 0.01-14.00pH |
| PH Resolution | 0.01pH |
| PH Accuracy | ±0.05pH |
| EC measuring range | 0.01-10mS/cm |
| EC Resolution | 0.01mS/cm |
| EC Accuracy | ±2% F.S |
| TEMP measuring range | 0.1°C-80.0°C; 32.0°F-176.0°F |
| TEMP Resolution | 0.1°C; 0.1°F |
| TEMP Accuracy | ±0.5°C |
| Fertility | 0~99% |
| Fertility Resolution | 0.01mS/cm |
| Fertility Accuracy | ±2% F.S |
| Moisture measuring range | 0~10 level |
| Light | 9 level |
| Work Environment | 0.1-80°C(32.0-176°F); RH 100% |
| LCD Display | Backlight Display |
| Battery | 4*AAA Batteries (Battery Not Included) |
3.3. YY-1080 Specification
| Parameter | Range/Resolution/Accuracy |
|---|---|
| PH measuring range | 0.00-14.00pH |
| PH Resolution | 0.01pH |
| PH Accuracy | ±0.05pH |
| EC measuring range | 0.01-120mS/cm |
| EC Resolution | 0.01mS/cm |
| EC Accuracy | ±2%F.S |
| Air humidity measuring range | 0~95% |
| Air humidity Resolution | 1% |
| Air humidity Accuracy | ±2%F.S |
| TEMP measuring range | 0.0°C-80.0°C; 32.0°F-176.0°F |
| TEMP Resolution | 0.1°C;0.1°F |
| TEMP Accuracy | ±0.5°C |
| Work Environment | 0-80°C(32.0-176°F); RH 100% |
| Display LCD | Backlight Display |
| Auto-shutdown | 5 minutes |
| Battery | 4*AAA Batteries (Battery Not Included) |
3.4. SGS07 Specification
| Parameter | Value |
|---|---|
| Model | SGS07 3-IN-1 Soil Tester |
| Applicable | Measure Soil Moisture, pH, Nutrients |
| PH Range | 3.0~9.0 PH |
| Moisture | 0%~90% |
| Temp | -10℃-90℃ (14°F-194°F) |
| Size | 61.71mm * 252.8mm |
| Battery Type | 3x AAA Alkaline Batteries Required (Not Included) |
3.5. THE01879 Specification
| Parameter | Range/Resolution/Accuracy |
|---|---|
| PH measuring range | 3.5-9PH |
| Fertility measuring range | 0-3000us/cm |
| Air Humidity measuring range | 0-99% |
| Soil Moisture measuring range | 0-99% |
| Environmental illumination measuring range | 0-100000 LUX |
| °C/°F measuring range | -9°C-50.0°C, 16°F-122°F |
| Product name | Multifunction Soil Meter |
| Material | ABS+Metal probe |
| Backlight | Yes |
| Screen | LCD display |
| Battery | 2* 1.5V AAA battery (No included) |




4. Setup
4.1. Battery Installation
Before first use, install the required AAA batteries (not included) into the device. The number of batteries varies by model (3 or 4 AAA batteries). Ensure correct polarity (+/-) when inserting batteries.


5. Calibration
The instrument is factory-calibrated, but recalibration may be necessary for high precision or after prolonged use.
5.1. pH Calibration
For pH calibration, you will need pH buffer powders (7.00, 4.00, 10.01) and 250ml of water per solution.
- Pour each pH buffer powder separately into a cup with 250ml of water and stir to dissolve.
- Switch on the power of the soil meter.
- Place the electrode into the 7.00 calibration solution.
- Select PH mode (pH will jump).
- Press and hold the CAL key for 5 seconds. The display will show '7.0 jumps' and '7.0 calibration complete'.
- Clean the electrode with pure water and dry it.
- Place the electrode into the 4.00 calibration solution.
- Press and hold the CAL key for 5 seconds. The display will show '7.0 Jump'.
- Short press the CAL key, '4.0 jumps'. Press CAL again, '10.0 jumps'. '4.0 calibration complete'.
- Clean the electrode with pure water and dry it.
- Place the electrode into the 10.01 calibration solution.
- Press and hold the CAL key for 5 seconds. The display will show '7.0 Jump'.
- Short press the CAL key, '4.0 jumps'. Press CAL again, '10.0 jumps'. '10.0 calibration complete'.
- Clean the electrode with pure water and dry it.
5.2. EC Calibration
For EC calibration, you will need 1413µs/cm (1.413mS/cm) calibration solution.
- Press the ON/OFF button to turn on the meter, rinse the probe with pure water and dry it.
- Put the probe into 1413µs/cm (1.413mS/cm) calibration solution and shake it gently. Wait until the reading is stable.
- Press the "CAL" button twice; "mS" will jump.
- Press and hold "CAL" for 5 seconds and then release. "CAL" will flash once on the screen, and then a value will flash.
- When the value starts flashing, press the "CAL" button (if the flashing value is higher than 1.41) or the "HOLD/TEMP" button (if the flashing value is lower than 1.41) to adjust the value to 1.41.
- After adjusting the display value to 1.41mS, release the button and wait for the reading to stop flashing.
- After calibration is completed, rinse the probe with pure water and wipe it clean.
6. Operating Instructions
6.1. General Measurement Procedure
- Press the ON/OFF button to turn on the tester.
- Rinse the probe with clean water and wipe dry.
- Insert the probe of the measuring instrument into the soil or solution (gently shake the measuring instrument when the measurement object is a solution). Ensure the probe is inserted at least 3-5 inches (8-10cm) into the soil.
- Wait for a few seconds until the reading is stable.
- Read the measured values from the LCD display.
- Press the ON/OFF button to turn off the instrument.
- Rinse the probe, wipe it clean, and store it.

6.2. Light Measurement
For models with a light meter:
- Press the ON/OFF button to turn on the device.
- Place the soil analyzer vertically at the measuring point.
- Align the Light Meter with direct sunlight.
- Read the instrument values for light intensity.
Note: When measuring, ensure that your body or plant leaves do not obstruct the light sensor. This instrument is designed for natural sunlight; artificial light sources may not yield accurate readings.

6.3. Soil Moisture Measurement
Test the soil for wetness to determine if watering is needed. The display will show moisture levels, often indicated by a scale or descriptive terms.

6.4. Soil pH Measurement
Soil pH is crucial for nutrient effectiveness and microbial activity. The meter provides a pH range reading.

6.5. Soil EC Measurement
EC (Electrical Conductivity) indicates the amount of nutrients available in the soil. Different plants have different optimal EC ranges.

6.6. Soil Fertility Measurement
Soil fertility measures the soil's ability to provide nutrients for crop growth.

6.7. Soil Temperature Measurement
Soil temperature determines plant survival and provides a comfortable growing environment.

6.8. Bluetooth Wireless Connection (for compatible models)
Some models offer Bluetooth connectivity to view temperature and humidity changes through a mobile app, facilitating healthier plant management.

6.9. Data Export (for compatible models)
Some models allow data export to Excel or email for detailed analysis.

7. Maintenance
7.1. Cleaning and Storage
Proper cleaning and storage are essential for the longevity and accuracy of your soil meter.
- After each use, rinse the probe with pure water and wipe it clean with a soft cloth to avoid rust and corrosion.
- Do not immerse the device completely in water.
- Store the device in a dry place.

7.2. Alcohol Cleaning (if needed)
If the probe requires deeper cleaning:
- Soak the probe in alcohol for 10 minutes.
- Clean the probe gently with a brush.
- Dry with a cloth before storing.

7.3. Battery Replacement
When the low battery indicator flashes on the display, it's time to replace the batteries.
- Open the battery protective cover.
- Remove the old batteries.
- Insert new AAA batteries, paying attention to the positive and negative poles.
- Close the battery cover.

8. Troubleshooting
- Q: What can I do if the meter can't be calibrated?
- A: If you encounter issues with calibration, please contact the manufacturer or seller for support. Ensure you are using fresh calibration solutions and following the steps precisely.
- Q: Why does the value jump when the test probe encounters air?
- A: When the test probe encounters air, it will generate resistance, and it is normal for the value to jump. Ensure the probe is fully immersed in the soil or solution for stable readings.
9. User Tips
- Do not immerse the probe in the measured object for a long time, as this can slow down the electrode reaction and affect accuracy.
- Avoid completely immersing the device in water. Only the probe should be inserted into the soil or solution up to the indicated water level line (e.g., 6cm).
- Do not use the meter to measure pure water, distilled water, or corrosive liquids, as this can damage the probe or provide inaccurate readings.
- Always insert the probe into soft soil. Do not force the probe into hard stones or compacted soil, as this will damage the probe.
- For best results, insert the probe into the soil at least 8cm, preferably 10cm or more, to ensure sufficient contact for accurate readings.
- When calibrating, gently stir the solution several times to ensure no air bubbles are around the electrode, which can interfere with the reading.
- For soil measurements, it is recommended to wet the soil with water before testing to ensure better conductivity and more accurate moisture readings.
10. Warranty and Support
We are committed to providing high-quality products and services. In case of non-human damage, we offer a 6-month warranty from the date of purchase. For any questions, issues, or support needs, please feel free to contact us. We aim to respond within 24 hours.
For additional information and detailed documents, you may refer to the official user manual PDF: User manual (PDF)