SUSWE SU1000

Contents

SUSWE SU1000 Voltage Converter User Manual

Model: SU1000 | Brand: SUSWE

1. Introduction

The SUSWE SU1000 is a high-power, dual inverter voltage converter designed to transform single-phase 220V input into stable three-phase 380V output. This device is ideal for powering various three-phase industrial and commercial equipment from a single-phase power source. It features pure sine wave output, ensuring compatibility and protection for sensitive machinery.

Key Features:

  • Converts 220V single-phase to 380V three-phase.
  • Pure sine wave output for stable and reliable power.
  • Supports customization for specific needs.
  • Safe, efficient, and energy-saving operation.
  • Equipped with soft start and soft stop functions to protect internal components and connected equipment.

2. Safety Information

Please read and understand all safety instructions before installing, operating, or maintaining the SU1000 voltage converter. Failure to follow these instructions may result in electric shock, fire, serious injury, or death.

  • Professional Installation: Installation and wiring should only be performed by qualified electricians or trained personnel.
  • Electrical Hazards: This device operates with high voltage. Do not open the casing or attempt repairs unless you are qualified.
  • Grounding: Ensure the device is properly grounded to prevent electric shock.
  • Ventilation: Install the converter in a well-ventilated area to prevent overheating. Maintain adequate clearance around the unit for airflow.
  • Environmental Conditions: Do not expose the unit to moisture, rain, direct sunlight, or extreme temperatures outside the specified operating range (-20℃ to 50℃).
  • Emergency Stop: Familiarize yourself with the emergency stop procedure and location of the power disconnect for the input supply.

3. Product Overview

SUSWE SU1000 Voltage Converter front view

Figure 1: Front view of the SUSWE SU1000 Voltage Converter

The SU1000 converter features a robust design with a user-friendly control panel and clearly labeled terminal block for electrical connections.

Control Panel:

The front panel includes a digital display for monitoring output frequency and voltage, along with control buttons:

  • Display: Shows current operating parameters (e.g., 50.00 Hz, 23.0V).
  • Buttons: Includes 'Press to stop to pause' and 'Press to run to start' buttons for controlling operation. Additional buttons for navigation and settings may be present depending on the model.

Terminal Block:

The terminal block provides secure connections for input and output wiring:

  • N: Neutral input
  • L: Live input
  • NC: Not Connected (or specific control terminal, refer to detailed wiring diagram)
  • U, V, W: Three-phase output terminals

4. Specifications

Product specifications parameters table

Figure 2: Product Specifications Parameters

Table 1: General Specifications
ParameterValue
Product NameSU1000
TypeDC/AC Inverter (Single-phase to Three-phase)
Power Rate4KW - 22KW (model dependent)
Input Voltage180V-250V (typically 220V single-phase)
Output Voltage380V ±1~3% (three-phase)
Output Frequency50-60HZ
Output Overvoltage Protection246±4V
Voltage Regulation Time<6S
Working Temperature-20℃ ~ 50℃
Weight13-25KG (model dependent)
CertificationCE, FCC

Physical Dimensions (Approximate):

  • 4KW Model: 43.5cm (L) x 31cm (W) x 24cm (H). Net Weight: 13.3kg, Gross Weight: 14.5kg.
    4KW model dimensions

    Figure 3: 4KW Model Dimensions

  • 7.5KW-15KW SM Model: 46cm (L) x 33cm (W) x 26cm (H).
    7.5KW-15KW SM model dimensions

    Figure 4: 7.5KW-15KW SM Model Dimensions

  • 15KW-22KW SM Model: 51cm (L) x 38cm (W) x 28cm (H).
    15KW-22KW SM model dimensions

    Figure 5: 15KW-22KW SM Model Dimensions

5. Setup

5.1 Power Sizing Considerations

When selecting a single-phase to three-phase transformer, it is crucial to consider the starting current of the connected equipment. Load-end devices often have a large instantaneous starting current, typically 1.5 to 2.5 times (or even 2-3 times) their normal operating current. To prevent equipment starting impact and ensure stable operation, it is recommended to choose a converter with a power rating that is at least 2 times (or 1.5-2.5 times) the rated power of your three-phase equipment.

Power magnification for single-phase to three-phase conversion

Figure 6: Power Sizing Recommendation

5.2 Wiring Diagram

The wiring process involves connecting the 220V single-phase mains power to the input terminals and the 380V three-phase output to your equipment. Ensure all connections are secure and properly insulated.

Wiring diagram for SU1000 voltage converter

Figure 7: Wiring Diagram

Wiring Steps:

  1. Input Power (220V Mains):
    • Connect the Neutral wire from your 220V single-phase mains to the 'N' terminal.
    • Connect the Live wire from your 220V single-phase mains to the 'L' terminal.
  2. Output Power (380V Three-Phase):
    • Connect the three-phase wires for your 380V electric machine to the 'U', 'V', and 'W' terminals.
  3. Grounding: Ensure a proper ground connection is established for both the converter and the connected equipment.
  4. Check Connections: Double-check all wiring for correctness and tightness before applying power.

6. Operating Instructions

6.1 Starting the Converter

After ensuring all wiring is correct and secure, and the power sizing is appropriate for your load:

  1. Apply 220V single-phase power to the converter.
  2. Press the 'Press to run to start' button on the control panel. The converter will initiate a soft start sequence, gradually increasing the output voltage to 380V three-phase. This soft start feature protects both the converter and your connected equipment from sudden power surges.
  3. Monitor the digital display to confirm stable output frequency (50/60Hz) and voltage (380V).
Soft start feature of the converter

Figure 8: Soft Start Operation

6.2 Stopping the Converter

To safely shut down the converter:

  1. Press the 'Press to stop to pause' button on the control panel. The converter will initiate a soft stop sequence, gradually reducing the output power.
  2. Once the output is off, disconnect the input 220V single-phase power.

7. Maintenance

Regular maintenance ensures the longevity and optimal performance of your SU1000 voltage converter.

  • Cleaning: Periodically clean the exterior of the unit with a dry, soft cloth. Ensure ventilation openings are free from dust and debris. Do not use liquid cleaners or solvents.
  • Inspection: Regularly inspect all wiring connections for tightness and signs of wear or damage. Check for any unusual noises, smells, or excessive heat during operation.
  • Environment: Ensure the operating environment remains within the specified temperature range (-20℃ to 50℃) and is free from excessive humidity or corrosive substances.

8. Troubleshooting

If you encounter issues with your SU1000 converter, refer to the following basic troubleshooting steps:

  • No Output Voltage:
    • Check if the input 220V power supply is active.
    • Ensure all input and output wiring connections are secure.
    • Verify the converter is powered on and not in a paused state.
  • Incorrect Output Voltage/Frequency:
    • Check the input voltage stability.
    • Ensure the load connected is within the converter's rated capacity, considering the power magnification factor for starting current.
    • If the issue persists, contact technical support.
  • Overheating:
    • Ensure adequate ventilation around the unit.
    • Check if the ambient temperature is within the operating range.
    • Reduce the load if it exceeds the converter's capacity.
  • Equipment Not Starting:
    • Re-evaluate the power sizing of the converter relative to the equipment's starting current (refer to Section 5.1). The converter's power rating might be insufficient for the equipment's initial surge.

9. User Tips

  • Power Matching is Critical: Always remember the recommendation to select a converter with a power rating 1.5 to 2.5 times (or even 2 times) the rated power of your three-phase equipment, especially for devices with high starting currents like motors, air compressors, or welding machines. This prevents startup issues and protects your equipment.
  • Application Versatility: The SU1000 is suitable for a wide range of three-phase equipment in various scenarios, including mixers, air compressors, elevators, central air conditioners, welding machines, and for general equipment debugging.
  • Voltage Compatibility: This converter is specifically designed for 220V single-phase input and 380V three-phase output. It is not directly compatible with other voltage conversions such as 240V single-phase to 415V three-phase without specific customization or a different model. Always verify the voltage requirements of your equipment against the converter's specifications.
  • Pure Sine Wave Advantage: The pure sine wave output ensures that even sensitive electronic equipment will operate smoothly and without damage, unlike modified sine wave inverters.

10. Warranty and Support

The SUSWE SU1000 Voltage Converter comes with a 2-year warranty, ensuring peace of mind regarding product quality and performance.

For technical assistance, warranty claims, or any questions not covered in this manual, please contact your retailer or the manufacturer's customer support. Provide your product model (SU1000) and details of the issue for efficient service.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.