1. Product Overview
The JIKONG JKBMS JK-B2A24S30P is an intelligent active balancing Battery Management System (BMS) designed for large-capacity series lithium battery packs. It offers comprehensive management and protection features, including voltage acquisition, high-current active balancing, overcharge, over-discharge, overcurrent, over-temperature protection, coulomb metering, Bluetooth communication, and optional GPS remote communication.
This BMS is suitable for various lithium battery types, including Lithium Iron Phosphate (LiFePO4), Ternary Lithium, and Lithium Titanate (LTO) batteries. It features energy transfer active balancing technology with a continuous balance current of up to 2A, ensuring battery consistency, extending battery life, and delaying aging.
The system is supported by a mobile APP (Android and iOS) that connects via Bluetooth, allowing users to monitor battery status, modify working parameters, and control charge/discharge switches. Its compact size, ease of operation, and full functionality make it ideal for applications in small sightseeing vehicles, mobility scooters, shared cars, high-power energy storage, base station backup power supplies, and solar power stations.


2. Specifications
The JIKONG JKBMS JK-B2A24S30P offers robust performance and features. Below are the key parameters and default settings.
2.1. Basic Parameters
| Parameter | Value | Unit |
|---|---|---|
| Supply Voltage | 20-100 | V |
| Operating Power Consumption | <1200 | mW |
| Operating Temperature | -30-70 | °C |
| Maximum Number of Collection Strings | 24 | String |
| Maximum Balancing Current | 2 | A |
| Maximum Charging Current | 300 | A |
| Maximum Discharge Current | 300 | A |
| Maximum Instantaneous Current | 600 | A |
| Maximum Internal Loop Resistance | 0.21 | mΩ |
| Protective Plate Size (L*W*H) | 208*120.7*15.6 | mm |
| Finished Weight | 675 | g |

2.2. Default Parameters
| Parameter | Li-ion (Ternary) | LiFePO4 | LTO | Unit |
|---|---|---|---|---|
| Balancing Initial Voltage | 3 | 3 | 2 | V |
| Maximum Balancing Current | 2 | 2 | 2 | A |
| Unit Overcharge Voltage | 4.2 | 3.6 | 2.7 | V |
| Single Overcharge Protection Recovery | 4.18 | 3.55 | 2.65 | V |
| Monomer Undervoltage Protection | 2.82 | 2.6 | 1.8 | V |
| Single Undervoltage Protection Recovery | 2.85 | 2.65 | 1.85 | V |
| Automatic Shutdown Voltage | 2.8 | 2.5 | 1.7 | V |
| SOC-0% Voltage | 2.9 | 2.6 | 1.85 | V |
| SOC-100% Voltage | 4.18 | 3.5 | 2.65 | V |
| Trigger Balancing Differential Pressure | 0.01 | 0.01 | 0.01 | V |
| Charging Overcurrent Protection Delay | 30 | 30 | 30 | S |
| Charge Overcurrent Protection Release Time | 60 | 60 | 60 | S |
| Discharge Overcurrent Protection Delay | 300 | 300 | 300 | S |
| Discharge Overcurrent Protection Release Time | 60 | 60 | 60 | S |
| Short-circuit Protection Delay | 1500 | 1500 | 1500 | µS |
| Short Circuit Protection Release Time | 60 | 60 | 60 | S |
| Charging Overtemperature Protection Temperature | 70 | 70 | 70 | °C |
| Charge Overtemperature Restore Temperature | 60 | 60 | 60 | °C |
| Discharge Overtemperature Protection Temperature | 70 | 70 | 70 | °C |
| Discharge Overtemperature Recovery Temperature | 60 | 60 | 60 | °C |
| Charging Low Temperature Protection Temperature | -20 | -20 | -20 | °C |
| Charge Low Temperature to Restore Temperature | -10 | -10 | -10 | °C |
| MOS Overtemperature Protection Temperature | 100 | 100 | 100 | °C |
| MOS Overtemperature Protection Recovery Temperature | 80 | 80 | 80 | °C |
| Device Address | 0 | 0 | 0 | / |
3. Setup and Installation
The JK-B2A24S-30P series protection board is suitable for 7-24 series lithium battery packs. The specific wiring method varies depending on the number of cells in the battery pack. Always ensure all cables are connected correctly before powering on the BMS.
3.1. Packing List

3.2. Wiring Instructions
Before connecting, ensure the battery pack is properly assembled and all individual cell voltages are within a safe range. Refer to the diagrams below for specific wiring configurations based on your battery string count.
- Connect all the balance cables (sampling lines) to the battery cells, starting from B- (total negative electrode) to B1, B2, and so on, up to the highest cell.
- Insert the balance cable connector into the BMS.
- Connect the B- line (total negative of battery) and the P- line (total negative for load/charger) to the battery and load/charger respectively.
- Connect the B+ line (total positive of battery) to the BMS power supply.
- If using the heating function, connect the heating wire and temperature control switch as shown in the diagram.
- For optional features like GPS, display, CAN, RS485, connect them to the respective interfaces on the BMS.
3.2.1. Wiring for 24-String Cells

3.2.2. Wiring for 8-String Cells

3.3. Device Activation
Before starting the protection board, double-check that the balance cables are properly connected and that the P- and B- terminals are correctly wired. Ensure the protection board is securely fixed to the battery pack. Incorrect connections can lead to abnormal operation or damage.
The protection board does not have a power-on control switch. It is designed for charging activation mode. To activate, connect the charger (charger voltage should be 2V higher than the battery voltage) after the battery assembly is complete. Alternatively, if you have a display screen and button, you can activate the BMS by inserting the cable into the display interface and pressing the button.
4. Operating Instructions
4.1. APP Installation and Usage
The JIKONG BMS can be managed and monitored via a mobile application available for Android (version 7 minimum required) and iOS systems. Scan the QR code below to download the official APP.

Once installed, connect the APP to the protection board via Bluetooth to:
- Check the real-time working status of the battery.
- Modify various working parameters of the protection board.
- Control the charge and discharge switches.

4.2. Active Equalization
The BMS uses active equalization to transfer energy from higher-voltage cells to lower-voltage cells, ensuring voltage balance with minimal energy loss. Before using this function, set the battery's basic parameters (battery type, number of cells, capacity, etc.) in the APP. The default balance current is 2A, but can be adjusted based on battery capacity (recommended not to exceed 0.2C).
The balance function automatically activates when the voltage difference between any two battery strings exceeds the set threshold and turns off when the difference falls below it. If not needed, the balancing switch can be turned off in the APP.


4.3. Protection Functions
The BMS includes several protection mechanisms to ensure the safety and longevity of your battery pack:
- Overcharge Protection: Automatically cuts off charging if any cell voltage exceeds the set overcharge protection voltage. Charging resumes when all cell voltages drop below the recovery voltage.
- Undervoltage Protection: Disables discharge if any cell voltage drops below the set undervoltage protection voltage. Discharge resumes when all cell voltages rise above the recovery voltage. The BMS will also automatically shut down if any cell voltage falls below the automatic shutdown voltage.
- Overcurrent Protection (Charge/Discharge): Triggers if the charging or discharging current exceeds the set continuous current for a specified delay. The BMS will cut off the respective operation and resume after the overcurrent release time. (Note: Max continuous discharge current is 300A).
- Overtemperature Protection (Charge/Discharge): Cuts off charging/discharging if the temperature exceeds the set overtemperature protection value. Operation resumes when the temperature drops below the recovery value.
- Low Temperature Protection (Charge): Cuts off charging if the temperature drops below the set low temperature protection value. Charging resumes when the temperature rises above the recovery value. For extremely cold environments, consider using the optional heating function.
- Short Circuit Protection: Automatically triggers if a short circuit is detected during charging or discharging. The protection board will cut off the operation and resume after the short circuit protection recovery time. The delay for short circuit protection can be adjusted via the APP.
4.4. Other Functions
- Heating Function (Optional): Supports heating the battery in low-temperature conditions using a resistance heater or heating film to maintain battery activity. The heating current is 10A. This function can be controlled via the APP. It is recommended to install a normally closed temperature switch (45°C to 65°C) in series with the heating circuit for secondary protection.
- Alarm Function: Provides external alarm notifications when the BMS detects safety risks such as overtemperature, overcharge, or overdischarge.
- Battery Parallel Function (Optional): Supports parallel connection of battery packs for energy storage applications. Requires synchronous use with parallel modules and disabling "charging current limiting" in the APP.
- ACC Detection Function: Used to enable discharge. Can be activated by applying 20-100V between ACC+ and ACC- or by short-circuiting ACC+ and ACC-. Also includes a charger detection function (C_detect+ and C_detect- for 12V charger output).
- Emergency Switch: When activated via the APP, the protection board will enable charge and discharge for 30 minutes, providing emergency operation time in case of over-temperature, over-discharge, over-charge, or string drop issues.
- Intelligent Sleep: The BMS can enter an intelligent sleep mode (standby current less than 1A for 26 consecutive hours) to reduce self-consumption. It can be reactivated by pressing a button or connecting a charger.
- Communication Function (Optional): Supports CAN/RS485 communication. Users can configure the address and communication protocol via the APP based on their specific needs. Refer to the Jikong Protection Board Communication Protocol document for details.
- GPS/Display Interface (Optional): The BMS has reserved interfaces for GPS and a display screen. Users can connect an optional GPS module for battery location tracking or a JIKONG display screen to view battery information.
5. Maintenance
Regular maintenance of your JIKONG JKBMS ensures optimal performance and longevity of your battery system.
- Regular Monitoring: Use the mobile APP to regularly monitor battery cell voltages, temperatures, and current. This helps in early detection of anomalies.
- Parameter Review: Periodically review and adjust the protection parameters (overvoltage, undervoltage, overcurrent, temperature limits) via the APP to match your battery's condition and usage environment.
- Connection Integrity: Ensure all wiring connections, especially the balance cables and main power connections (P- and B-), are secure and free from corrosion. Loose connections can lead to inaccurate readings or system malfunctions.
- Firmware Updates: Check the JIKONG official website or APP for any available firmware updates to ensure your BMS has the latest features and bug fixes.
- Physical Inspection: Inspect the BMS board for any signs of physical damage, overheating, or loose components. Ensure proper ventilation around the BMS to prevent heat buildup.
- Cleaning: Keep the BMS and its connectors clean and free from dust and debris. Use a soft, dry cloth for cleaning.


6. Troubleshooting
This section provides guidance on common issues you might encounter with your JIKONG JKBMS.
- BMS Not Activating:
- Ensure all balance cables and main power connections (P- and B-) are correctly and securely connected.
- Verify that the battery pack is properly assembled and fixed.
- If using charging activation, ensure the charger voltage is at least 2V higher than the battery voltage.
- If using a display and button, ensure the cable is inserted correctly and the button is pressed.
- Abnormal Readings/Balancing Issues:
- Check all balance wire connections for looseness or corrosion.
- Verify that the battery type and cell count are correctly configured in the APP.
- Ensure the balance trigger differential pressure is set appropriately in the APP.
- Protection Triggering Frequently (Overvoltage, Undervoltage, Overcurrent, Overtemperature, Short Circuit):
- Review the default and custom protection parameters in the APP. They might be set too aggressively for your battery or application.
- For overcurrent protection, ensure the continuous current settings match your load and charger capabilities. For short circuit, consider increasing the delay time if false triggers occur due to inrush currents.
- For temperature protections, ensure NTC sensors are correctly placed and functioning. If in a cold environment, consider enabling the heating function.
- Check the battery pack health; a weak cell can cause frequent undervoltage triggers.
- Bluetooth Connection Issues:
- Ensure the APP is installed correctly and your mobile device meets the minimum Android 7 requirement.
- Restart the APP and your phone's Bluetooth.
- Ensure the BMS is powered on and within Bluetooth range.
- Check the Bluetooth connection indicator on the BMS (if available); it should be steady when connected and blinking when disconnected.
- Heating Function Not Working:
- Verify the heating wire and temperature control switch are correctly installed.
- Check the temperature control switch's set point; it might be too high for activation.
- Ensure the heating function is enabled in the APP.
If you encounter persistent issues, refer to the full PDF manual (link provided in the product description) or contact JIKONG technical support.
7. User Tips
- Initial Setup: Always double-check all wiring, especially the balance leads, before applying power. Incorrect wiring is the most common cause of initial setup problems.
- APP Customization: Take advantage of the mobile APP to fine-tune protection parameters to match your specific battery chemistry and usage patterns. This can significantly improve battery performance and lifespan.
- Temperature Management: Pay close attention to battery temperatures, especially during high charge/discharge cycles or in extreme weather. Utilize the heating function in cold conditions and ensure adequate ventilation in hot conditions.
- Monitoring: Regularly check the APP for real-time data on cell voltages, current, and temperature. This proactive monitoring can help identify potential issues before they become critical.
- Safety First: Always handle battery packs with care. Ensure proper insulation and secure mounting of the BMS to prevent short circuits or physical damage.
8. Warranty and Support
For detailed warranty information, technical support, and service inquiries, please refer to the official JIKONG documentation or contact JIKONG customer service directly. The full user manual in PDF format is available for download via the link provided in the product description.
JIKONG Official Store: Visit Store