1. Introduction
The INVT Goodrive10 series is an economical Variable Frequency Drive (VFD) designed for three-phase 380V applications. It features advanced SVPWM control, a compact design for efficient space utilization, and a built-in PID controller with 16-step speed control capabilities. This VFD is suitable for a wide range of industrial applications requiring precise motor control and energy efficiency.
Key Features:
- SVPWM control for enhanced performance.
- Compact design requiring less installation space.
- Built-in PID functionality with 16-step speed control.
- Standard potentiometer and external LED keypad for user-friendly operation.
- Optional C3 and C2 filters for improved electromagnetic compatibility.
- Natural cooling for single-phase or three-phase 220V 0.2-0.75kW models.
- CE certified, ensuring compliance with European safety standards.
Applications:
The Goodrive10 VFD is ideal for various industries, including:
- Packing machinery
- Food processing equipment
- Textile machinery
- Centrifugal machinery
- Carving machinery
- Wire cutting applications
2. Important Safety Warnings
Please read and understand all safety warnings before installation, operation, or maintenance of the VFD. Failure to comply may result in serious injury or equipment damage.

Specific Warnings:
- Risk of Electric Shock: Always ensure power is disconnected before installing or performing any maintenance. Wait at least 5 minutes after power off before proceeding, as capacitors may retain charge.
- Hot Surfaces: The heat sink of the VFD can become very hot during operation. Do not touch the heat sink or surrounding areas without proper cooling time.
- Read Manual: Always read the complete user manual before installation and operation to prevent accidents and ensure correct usage.
3. Technical Specifications
The following table details the technical specifications for the INVT Goodrive10 VFD series:

| Function | Specification |
|---|---|
| Power Input | |
| Input voltage (V) | Three-phase 220V (-15%) - 240V (+10%) Three-phase 380V (-15%) - 440V (+10%) |
| Input current (A) | Refer to 2.5 |
| Input frequency (Hz) | 50Hz or 60Hz, Allowed range: 47-63Hz |
| Power Output | |
| Output voltage (V) | =the input voltage (error<5%) |
| Output current (A) | Refer to 2.5 |
| Output power (kW) | Refer to 2.5 |
| Output frequency (Hz) | 50Hz/60Hz, fluctuation ±5% |
| Technical Control | |
| Control mode | SVPWM |
| Maximum output frequency | 400Hz |
| Adjustable-speed ratio | 1:100 |
| Overload capability | 150% of rated current: 1 minute 180% of rated current: 10 seconds |
| Key functions | Stop mode and anti-overtemperature of the bus |
| Temperature measurement accuracy | Overtemperature point ±3°C |
| Peripheral Interface | |
| Terminal switch input resolution | ≤ 2ms |
| Terminal analog input resolution | ≤ 20mV |
| Analog input | 1 input 0-10V/0-20mA |
| Analog output | 1 output 0-10V/0-20mA |
| Digital input | 5 common input |
| Digital output | 1 Y output (commonly used with digital output) and 1 programmable relay output |
| Communication | 485 communication |
| Running Control | |
| Running control methods | Digital setting, analog setting, multi-step speed setting, PID setting, MODBUS communication setting and so on. Switch between different settings. |
| Automatic voltage adjustment | Keep output voltage stable when the grid voltage changes. |
| Fault protection | More than 10 fault protections. |
| Other | |
| Mountable method | Wall mountable |
| Temperature of the running environment | -10~50°C. If temperature is above 40°C, derate 1% for every additional 1°C. |
| Cooling | Single-phase/three-phase 220V 0.2-0.75kW natural cooling; Single-phase/three-phase 220V 1.5-2.2kW, three-phase 380V 0.75-2.2kW. |
| Pollution degree | 2 |
| Braking unit | Embedded |
| DC reactor | Not optional |
| Braking resistor | Optional and external |
| EMC filter | Optional C3 or C2 filter |
Physical Dimensions and Weight:
- Size: 165mm (H) * 100mm (W) * 154mm (D) (for models GD10-0R7G-4-B, GD10-1R5G-4-B, GD10-2R2G-4-B)
- Weight: 3.5kg


4. Setup and Installation
4.1 Unpacking and Inspection
- Carefully unpack the VFD and inspect for any signs of damage during transit.
- Verify that all components listed in the packing list are present.
- If any damage or missing parts are found, contact your supplier immediately.
4.2 Mounting
The Goodrive10 VFD is designed for wall mounting. Ensure the mounting surface is stable and capable of supporting the VFD's weight (approx. 3.5kg). Allow adequate clearance for ventilation, especially around the heat sink.

4.3 Wiring
Wiring should only be performed by qualified personnel. Ensure all power is disconnected and locked out before making any connections. Refer to the detailed wiring diagrams in the full product manual for specific terminal connections.
4.4 Keyboard Installation (External)
If using an external keypad, refer to the following diagram for proper installation opening dimensions:

5. Operation
5.1 Control Panel Overview
The VFD features a user-friendly control panel with a display and various buttons for programming and operation.

Key Buttons:
- PRG/ESC: Program/Escape button. Used to enter/exit programming mode and escape from current menu.
- QUICK/JOG: Quick/Jog button. Used for quick parameter access or jog operation.
- RUN: Starts the motor.
- STOP/RST: Stops the motor and resets faults.
- DATA/ENT: Data/Enter button. Used to confirm parameter settings.
- SHIFT: Shift button. Used to move cursor during parameter editing.
- Up/Down Arrows: Used to navigate menus and adjust parameter values.
5.2 Basic Operation
- Power On: Apply power to the VFD. The display will light up.
- Frequency Setting: Use the Up/Down arrows or the potentiometer to set the desired output frequency.
- Start Motor: Press the RUN button to start the motor.
- Stop Motor: Press the STOP/RST button to stop the motor.
- Fault Reset: If a fault occurs, address the cause, then press the STOP/RST button to clear the fault.
5.3 Advanced Control Modes
The Goodrive10 supports various running control methods, including digital setting, analog setting, multi-step speed setting, PID setting, and MODBUS communication. Refer to the comprehensive manual for detailed instructions on configuring these advanced modes.
5.4 Product Overview Video
Watch this short video for a visual overview of the INVT Goodrive10 VFD:
6. Maintenance
Regular maintenance ensures the longevity and optimal performance of your VFD. Always disconnect power before performing any maintenance.
6.1 Cleaning
- Keep the VFD clean and free from dust and debris. Use a soft, dry cloth for cleaning.
- Periodically clean the heat sink fins to ensure efficient heat dissipation.
6.2 Environmental Conditions
- Ensure the operating environment temperature remains within -10°C to 50°C.
- If the ambient temperature exceeds 40°C, the VFD's output capacity must be derated by 1% for every additional 1°C to prevent overheating.
- Maintain proper ventilation around the VFD.
6.3 Inspection
- Regularly check all wiring connections for tightness and signs of wear or damage.
- Inspect the VFD for any unusual noises, smells, or visual abnormalities.
7. Troubleshooting
The Goodrive10 VFD is equipped with over 10 fault protections. When a fault occurs, the VFD will display an error code. Refer to the full manual for a complete list of error codes and their remedies. Below are some common issues:
| Problem | Possible Cause | Solution |
|---|---|---|
| Motor does not start | No power, incorrect wiring, fault condition, frequency set to 0. | Check power supply, verify wiring, clear any faults, ensure frequency is set above 0. |
| Overcurrent fault | Motor overload, short circuit, rapid acceleration/deceleration. | Reduce load, check motor/cables for shorts, adjust acceleration/deceleration times. |
| Overvoltage/Undervoltage fault | Input voltage fluctuation, regenerative braking. | Check input power supply, consider adding a braking resistor if regenerative braking is an issue. |
| Overheat fault | Insufficient ventilation, high ambient temperature, clogged heat sink. | Ensure proper ventilation, clean heat sink, reduce load if ambient temperature is high. |
For any persistent issues or complex fault codes, consult the detailed troubleshooting section of the complete user manual or contact technical support.
8. User Tips
- Parameter Backup: Before making significant changes to parameters, record the current settings. This allows for easy restoration if unintended behavior occurs.
- Motor Tuning: For optimal performance, especially with demanding loads, consider performing an auto-tuning function (if available in your specific model's firmware) to match the VFD to your motor's characteristics.
- Cable Length: Keep motor cable lengths as short as possible to minimize voltage drop and electromagnetic interference.
- Grounding: Ensure proper grounding of both the VFD and the motor to prevent electrical noise and ensure safety.
9. Frequently Asked Questions (FAQ)
- Q: Can I use this VFD with a single-phase motor?
- A: No, this specific series (GD10-xG-4-B) is designed for three-phase 380V input and output. Please check the model number carefully for compatibility.
- Q: What is the maximum frequency output?
- A: The maximum output frequency is 400Hz.
- Q: Is an external keypad necessary?
- A: The VFD comes with a standard potentiometer and an integrated LED keypad for basic operation. An external keypad is optional for remote control or specific installation requirements.
- Q: How do I reset a fault?
- A: After addressing the cause of the fault, press the STOP/RST button on the control panel to clear the fault and resume operation.
10. Warranty and Support
For detailed warranty information, including coverage period and terms, please refer to the warranty card included with your product or contact your authorized INVT distributor. Technical support is available through your point of purchase or the official INVT service channels.