PINTECH PT-350

Rate this product if you’ve used it
Contents

PINTECH PT-350 AC/DC Current Probe Instruction Manual

Model: PT-350

1. Introduction

Thank you for choosing the PINTECH PT-350 AC/DC Current Probe. This high-frequency current probe is designed for accurate current measurements in various electronic applications when used with an oscilloscope. It offers a wide bandwidth and high sensitivity, making it suitable for analyzing complex current waveforms in power supplies, semiconductor devices, motor drives, and more.

This manual provides essential information for the safe and effective use of your PT-350 current probe. Please read it thoroughly before operation and keep it for future reference.

2. Product Overview

The PINTECH PT-350 is a versatile AC/DC current probe featuring a compact design and a 5mm clamp diameter for easy attachment to conductors. It provides a 0.1V/A conversion ratio, allowing for direct current waveform observation on an oscilloscope.

PINTECH PT-350 AC/DC Current Probe showing the probe, controller, and cable.
Figure 1: PINTECH PT-350 AC/DC Current Probe components.

2.1 Key Features

  • Wide Bandwidth: DC-50MHz
  • High Current Capability: 60A Peak, 40A RMS
  • High Accuracy: 3%
  • Low Noise: <1mV
  • Fast Rise Time: <7ns
  • AC/DC Coupled Mode
  • Compact Clamp Design: 5mm diameter
  • Standard 0.1V/A Conversion Ratio

2.2 Applications

The PT-350 current probe is ideal for a wide range of applications, including but not limited to:

  • Power supply design and testing
  • Semiconductor device characterization
  • Inverter and converter analysis
  • Motor drive control systems
  • General power electronics measurements
  • Industrial and home appliance diagnostics
  • Communications equipment testing
  • Medical device research and development
  • Transportation and aerospace electronics
Detailed product features, including datasheet, application examples, product appearance, function testing, and power adapter.
Figure 2: Detailed product features, specifications, and application examples.

3. Specifications

The following table details the technical specifications for the PINTECH PT-350 AC/DC Current Probe:

Parameter Specification (PT-350)
Model PT-350
Bandwidth DC-50MHz
Peak Pulse Current 60A Peak
Maximum Current 40A RMS
Minimum Test Current 20mA
Accuracy 3%
Noise <1mV
Rise Time <7ns
Coupled Mode AC/DC
Power Supply 9V
Clamp Diameter 5mm
Conversion Ratio 0.1V/A

4. Setup

Follow these steps to set up your PINTECH PT-350 current probe:

  1. Unpack the Probe: Carefully remove the current probe and its accessories from the packaging.
  2. Connect to Oscilloscope: Connect the BNC connector of the current probe's cable to an input channel of your oscilloscope. Ensure a secure connection.
  3. Power On: Connect the 9V power adapter to the probe's controller unit and plug it into a suitable power outlet. The probe requires external power for operation.
  4. Oscilloscope Settings:
    • Set the oscilloscope input impedance to 50Ω (if available and appropriate for your oscilloscope model) or 1MΩ.
    • Adjust the vertical scale (Volts/Div) on your oscilloscope. Since the probe has a 0.1V/A conversion ratio, 1V on the oscilloscope screen will represent 10A of current. For example, if you set the oscilloscope to 100mV/Div, each division will represent 1A.
    • Set the coupling mode on the oscilloscope to DC for measuring both AC and DC components, or AC for measuring only AC components.

5. Operating Instructions

5.1 Zero Adjustment (DC Current Measurement)

Before measuring DC current, it is crucial to perform a zero adjustment to eliminate any offset. This ensures accurate readings.

  1. Ensure no current is flowing through the clamp (i.e., the clamp is open or around a conductor with no current).
  2. Locate the button on the probe's controller unit (refer to Figure 2, 'Functions Testing' section).
  3. Press and hold this button until the red LED illuminates.
  4. Release the button. When the LED turns off, the probe is zeroed and ready for DC current measurement.

5.2 Measuring Current

  1. Open the Clamp: Use the thumb wheel on the probe to slide and open the clamp jaws. The maximum conductor diameter is 5mm.
  2. Position the Conductor: Place the conductor carrying the current you wish to measure within the center of the clamp jaws. Ensure the clamp is fully closed around the conductor.
  3. Observe Waveform: Observe the current waveform on your oscilloscope screen.
  4. Interpret Readings: Use the oscilloscope's vertical scale and the probe's 0.1V/A conversion ratio to interpret the current values. For example, if the oscilloscope displays 0.5V, the current is 5A.

Important: For accurate measurements, ensure only one conductor is placed within the clamp at a time. Measuring multiple conductors will result in a sum of their currents.

6. Maintenance

  • Cleaning: Keep the probe and its accessories clean. Use a soft, dry cloth to wipe the exterior. Do not use abrasive cleaners or solvents.
  • Storage: Store the probe in a clean, dry environment, away from extreme temperatures and humidity. Protect the clamp jaws from damage.
  • Cable Care: Avoid sharp bends or kinks in the cable. Do not pull on the cable to disconnect it; always grasp the connector.
  • Power Adapter: Use only the provided 9V power adapter or a compatible replacement with the correct voltage and current rating.

7. Troubleshooting

No waveform or incorrect reading on oscilloscope:
  • Ensure the probe is properly connected to the oscilloscope input.
  • Verify the probe's power adapter is connected and the probe is powered on.
  • Check the oscilloscope's input channel settings (e.g., correct vertical scale, coupling mode).
  • Ensure the clamp is fully closed around a single conductor carrying current.
  • Perform a zero adjustment if measuring DC current.
  • Check if the current being measured is within the probe's specified range (20mA minimum, 60A Peak maximum).
Red LED on controller unit does not light up:
  • Verify the power adapter is correctly connected and receiving power.
  • Ensure the power adapter is functioning correctly.
Inaccurate DC current measurement:
  • Ensure a proper zero adjustment has been performed before measurement.
  • Check for external magnetic fields that might interfere with the measurement.

8. Warranty and Support

PINTECH products are manufactured to high-quality standards. For warranty information and technical support, please contact your authorized PINTECH distributor or the official PINTECH customer service. Please have your product model (PT-350) and purchase details ready when contacting support.