1. Introduction
The PEAKMETER PM701 Series EVSE Adapter is a professional tool designed for testing electric vehicle charging stations. It offers broad compatibility with international standards such as SAE J1772, European Standard, and NACS. This adapter provides comprehensive testing capabilities, exceptional safety features, and a robust design, enabling effective simulation of charging states, detection of electrical faults, and instant feedback. It is an ideal choice for ensuring the safe and reliable operation of EV charging stations during installation, maintenance, and troubleshooting.
Figure 1: Front view of the PEAKMETER PM701 EVSE Adapter.
2. Safety Information
Always observe safety precautions when working with electrical equipment. This device is designed for professional use. Ensure you understand all functions and potential hazards before operation.
- Read all instructions carefully before use.
- Do not operate the device if it appears damaged.
- Ensure proper grounding of the charging station before testing.
- Wear appropriate personal protective equipment (PPE).
- Refer to local electrical codes and regulations.
3. Setup
- Unpacking: Carefully remove the PM701 EVSE Adapter from its packaging. Verify all components are present: the adapter unit, and any included accessories.
- Initial Inspection: Inspect the adapter for any visible damage. Do not use if damaged.
- Connecting to a Charging Station:
Connect the PM701 EVSE Adapter to the EV charging station's charging cable. Ensure a secure connection. Note that different specifications exist in different regions; matching plug adapters may be used if necessary.
Figure 2: Connecting the PM701 to a charging station.
4. Operating Instructions
4.1. Pre-Test (Ground Connection Safety Check)
Before proceeding with any charging process inspection, ensure the safety of the ground connection to the AC EV Charger.
- Connect the PM701 to the charging station.
- Set the "CP STATE" knob on the PM701 to "A" to simulate the charge station being connected.
- Touch the "Touch" metal contact with your bare finger.
- Observe the "PE Pre-Test" red LED indicator. If it does not light up, it means there is no voltage in the ground, indicating a safe connection.
Figure 3: Close-up of PM701 controls during pre-test, showing the 'Touch' contact and 'PE Pre-Test' indicator.
4.2. Charging Process Inspection
- Standby Simulation:
Turn the "CP STATE" knob to "B" mode. This simulates that the EV Charger is connected to an EV, but charging has not yet started.
Observe the EV charger's display. It should indicate "ready" to operate, or display instructions such as "ask for payment," "connect with your smartphone," or "enter your password/token." This verifies the charger is working in standby state.
- Charging Simulation:
Turn the "CP STATE" knob to "C" mode to simulate active charging.
Based on the maximum charging current of the charging station, turn the current knob (e.g., 13A, 20A, 32A, 63A) to the corresponding Ampere. The output current must be set to match the cable used by the user, especially if the charger doesn't come with a charging cable.
The EV Charger should now indicate that it is charging. If the charging point is connected to a 3-phase electric power, the L1, L2, L3 LEDs on the PM701 will light up.
4.3. Error Simulation
The PM701 allows for simulating error conditions to test the safety response of the EV charger.
- CP Error Simulation:
Press the "CP Error" button. A pseudo error will occur simultaneously.
Observe whether the AC signal lights (L1, L2, L3) on the PM701 go off and if the EV charger immediately stops charging. This confirms the charger's ability to stop charging to avoid a serious accident in case of a CP error.
- PE Error Simulation:
Press the "PE Error" button. This creates a ground cable interrupted situation.
Observe if the EV charger immediately stops charging. This indicates the charge station is safe and responds correctly to a ground fault.
4.4. Working with Other Testers
The PM701 can be used in conjunction with other testing equipment for more detailed analysis.
- Multimeter Connection: Connect a multimeter to the L1, L2, L3, N, and PE terminals to measure voltage values in each mode when the EV charger is working.
- Oscilloscope Connection: Connect an oscilloscope to the CP signal output terminal to check the waveform when the device is working.
Figure 4: PM701 adapter connected to a multimeter for measuring voltage values.
Video 1: Demonstration of PM701 EVSE Adapter usage, including pre-test, charging simulation, and error simulation, and connection to other testers.
5. Maintenance
- Cleaning: Use a soft, dry cloth to clean the device. Do not use abrasive cleaners or solvents.
- Storage: Store the adapter in a cool, dry place, away from direct sunlight and extreme temperatures.
- Inspection: Regularly inspect the cables and connectors for any signs of wear or damage. Replace if necessary.
6. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| PE Pre-Test LED lights up | Voltage exists in the ground connection. | Do not proceed with testing. Inspect the charging station's grounding for faults. |
| EV Charger does not respond to "B" (Standby) mode | Incorrect connection, charger fault, or incompatible standard. | Ensure secure connection. Verify charger functionality independently. Check PM701 model compatibility with charger standard (SAE J1772, Type2, NACS). |
| EV Charger does not respond to "C" (Charging) mode | Incorrect current setting, charger fault, or cable issue. | Adjust current knob to match charger/cable. Check charger for errors. Inspect charging cable. |
| EV Charger does not stop charging during CP or PE Error simulation | Safety mechanism failure in EV charger. | Immediately disconnect the PM701 and EV charger. The EV charger is unsafe and requires professional repair. |
7. Specifications
| General Specifications | |
|---|---|
| Product Name | EVSE Adapter |
| Model Number | PM701 Series (PM701U, PM701E, PM701UT) |
| Test Object | AC charging station |
| Test Interface | Complies with SAE J1772 standard (PM701U), Type2 (European Standard) (PM701E), NACS (Tesla) (PM701UT) |
| Simulate Charging State | A, B, C or D |
| PE Pre-Testing | Yes |
| CP Pre-Testing | Yes |
| Simulate Cable Resistance | Yes |
| Simulated CP Error | Yes |
| Simulated PE Error | Yes |
| Leakage Tripping Test | ≥6mA/110V (PM701U, PM701UT) |
| Charging Output Terminal | 4mm port/American standard socket (PM701U, PM701UT), 4mm port/European standard socket (PM701E) |
| Support Voltage Types | Single phase or three-phase |
| Indicator Light | Yes |
| Fuse | 10A/250V |
| Voltage | <250V single-phase & <480V 3-phase voltage systems |
| Power | ≤3W |
| Applicable Models | Electric Car |
| Place of Origin | Guangdong, China |
| Environmental & Safety | |
|---|---|
| Protection Grade | Case IP54 |
| Safety Rating | IEC/EN 61010-1, IEC/EN61010-2-030, CAT III 600V |
| Measurement Category | IEC/EN 61851-1, IEC/HD 60364-7-722 |
8. User Tips
- Always double-check the "PE Pre-Test" indicator before proceeding with any other tests to ensure a safe ground connection.
- When simulating charging, ensure the current setting on the PM701 matches the charging station's maximum current and the connected cable's capacity to avoid false readings or potential issues.
- Utilize the error simulation features regularly to confirm the safety mechanisms of your EV charging stations are functioning correctly.
9. Warranty and Support
The PEAKMETER PM701 Series EVSE Adapter comes with a 12-month warranty from the date of purchase. For technical support, troubleshooting assistance, or warranty claims, please contact LINGXUN Auto Parts Store or visit the official PEAKMETER website.
Official Website: www.peak-meter.com