1. Introduction
The JIKONG JKBMS Inverter is an advanced Battery Management System (BMS) designed for efficient and safe management of various battery types, including LiFePO4, Li-ion, and LTO. This smart BMS is tailored for applications such as home energy storage systems, communication base stations, building energy storage, and industrial equipment backup power. It features active balancing, comprehensive protection functions, and versatile communication interfaces, ensuring optimal battery performance and longevity.

2. Key Features
- Active Balancing (Lossless Balancing): Achieves energy transfer between cells with higher and lower energy, ensuring voltage balance with minimal energy loss.
- Wide Voltage Range: Single cell voltage range of 1V to 5V, with balancing accuracy of ±5mV.
- High Balancing Current: Supports 2-10A continuous balanced current for improved battery consistency and extended lifespan.
- Mobile Bluetooth Communication: Equipped with a mobile APP for real-time battery status viewing, compatible with Android and iOS.
- Balanced Cascade Support: Suitable for battery packs with more than 24 cells.
- Multi-Battery Type Compatibility: Works with LiFePO4, Ternary Lithium, and Lithium Titanate batteries.
- Comprehensive Protection: Includes overcharge, over-discharge, overcurrent, short circuit, and 4-way temperature detection protection.
- MOS Temperature Detection Protection: Monitors and protects MOS components from overheating.
- Heating Function: Integrated heating capability for optimal battery operation in various conditions.
- Multiple Communication Interfaces: Supports RS485, CAN, and RS232 for PC computer monitoring and inverter protocol selection.
- Information Display: Provides real-time data on voltage, current, temperature, SOC, and accurate time records.
- Isolated Power Circuit: Enhances safety and reliability.


3. Package Contents
The standard package for the JIKONG Home Energy Storage BMS includes the following components:
- 1 * BMS Unit
- 1 * Interface Board
- 1 * Adapter Cable A (long 40cm)
- 1 * Adapter Cable B (long 40cm)
- 1 * Adapter Cable C (long 40cm)
- 1 * RS485 Cable (long 40cm)
- 2 * Sampling Line A (long 90cm)
- 2 * Sampling Line B (long 90cm)
- 1 * Sampling Line C (long 90cm)
- 1 * Switch (long 50cm)
- 1 * Heating Adapter Cable (long 15cm)
- 1 * 4.3 inch Touch Screen Display
- 1 * USB RJ45 RS485 Cable


4. Specifications
| Technical Index | JK-PB1A16S10P | JK-PB1A16S15P | JK-PB2A16S15P | JK-PB2A16S20P |
|---|---|---|---|---|
| Number of Battery Strings (Li-ion) | 7S-16S | 7S-16S | 7S-16S | 7S-16S |
| Number of Battery Strings (LiFePO4) | 8S-16S | 8S-16S | 8S-16S | 8S-16S |
| Number of Battery Strings (LTO) | 14S-16S | 14S-16S | 14S-16S | 14S-16S |
| Balance Method | Active Balance (Full State On) | |||
| Balance Current | 1A | 1A | 2A | 2A |
| Conductive Resistance in Main Circuit | 0.8mΩ | 0.4mΩ | 0.4mΩ | 0.3mΩ |
| Continuous Discharge Current | 100A | 150A | 150A | 200A |
| Maximum Discharge Current (MAX 2min) | 200A | 300A | 300A | 350A |
| Over Charge Protection Current (ADJ) | 10-100A | 10-150A | 10-150A | 10-200A |
| Other Interfaces (Default) | RS485/232/CAN | |||
| Wiring Output | Common Port | |||
| Single Cell Voltage Range | 1-5V | |||
| Voltage Acquisition Accuracy | ±5mV | |||
| Over Charge Protection Voltage | 1.2-4.35V Adjustable | |||
| Over Charge Release Voltage | 1.2-4.35V Adjustable | |||
| Over Current Detect Delay | 2-120S Adjustable | |||
| Over Discharge Protection Voltage | 1.2-4.35V Adjustable | |||
| Over Discharge Release Voltage | 1.2-4.35V Adjustable | |||
| Quantity of Temperature Detection | 4 | |||
| Temp Protection | Yes | |||
| Short Circuit Protection | Yes | |||
| Coulomb Counter | Yes | |||
| Bluetooth Function | Support for Android/iOS/Harmony | |||
| Parallel Charging Current Limiting | 10A | |||
| Address Dial Switch | 4 | |||
| DRY Contact | 2 | |||

5. Installation and Wiring
Proper installation and wiring are crucial for the safe and effective operation of your JIKONG BMS. Please follow these steps carefully:
- Connect all the cables: Ensure all necessary cables (sampling lines, adapter cables, communication cables) are prepared and ready for connection.
- Insert the cable into the BMS: Carefully connect the sampling lines and other relevant cables to their designated ports on the BMS unit.
- Connect the B-line and the P-line to the battery: Connect the main battery negative (B-) and positive (P+) lines to the corresponding terminals on the BMS.
- Important Note on B8 Cables: If your setup involves two B8 cables, only the first B8 line needs to be connected. The second B8 cable does not need to be connected.


6. Operation
6.1. 4.3-inch Touch Screen Display
The 4.3-inch LCD provides real-time monitoring of your battery system. It displays critical information such as:
- Battery Pack Total Voltage (Vol)
- Output Current (Cur)
- State of Charge (SOC)
- Delta Voltage (Delta Vol)
- Average Voltage (Ave Vol)
- MOS Temperature (MOS Temp)
- Balance Status (ON/OFF)
- Charge/Discharge Status (ON/OFF)
- Alarm Indicators (Alarm)
The display supports both English and Chinese languages. A long press on the physical switch connected to the display can turn the BMS on or off.


6.2. Mobile App Operation
The JIKONG BMS can be easily managed and monitored via a dedicated mobile application, available for Android and iOS devices. The app provides a comprehensive overview of the battery system and allows for parameter adjustments.
- Real-time Data: View voltage, current, temperature, SOC, and cycle data.
- Parameter Adjustment: Freely adjust multiple protection values such as overcharge, over-discharge, overcurrent, temperature, and balance settings.
- Alarm Function: Receive and view alarms directly within the app.
- Inverter Protocol Selection: Easily select the appropriate inverter communication protocol.

6.3. PC Software Monitoring
For advanced monitoring and configuration, the JIKONG BMS supports PC computer monitoring via RS485, CAN, and RS232 interfaces. This allows for detailed data logging, parameter adjustments, and inverter protocol settings.
- Comprehensive Monitoring: Access detailed real-time data and historical records.
- Parameter Configuration: Adjust protection parameters and operational settings.
- Inverter Protocol Setting: Configure the inverter communication protocol through the host computer.

6.4. Communication Interfaces
The JIKONG BMS offers multiple communication modes for versatile integration:
- CAN
- RS485
- UART
- RS232

Video 1: JIKONG Home Energy Storage BMS Overview
7. Maintenance
To ensure the long-term reliability and performance of your JIKONG JKBMS, regular maintenance is recommended:
- Visual Inspection: Periodically check all cables and connections for any signs of wear, damage, or loose contacts. Ensure the BMS unit is free from dust and debris.
- Firmware Updates: Check the official JIKONG website or app for any available firmware updates. Keeping the firmware up-to-date can improve performance and add new features.
- Environmental Conditions: Ensure the BMS operates within its specified temperature and humidity ranges to prevent damage.
- Battery Health Monitoring: Regularly monitor battery cell data via the display or mobile app to identify any anomalies early.
8. Troubleshooting
If you encounter issues with your JIKONG JKBMS, consider the following troubleshooting steps:
- No Power/Display: Verify all power connections are secure. Check the main battery lines (B- and P+) and ensure the BMS switch is in the ON position.
- Balancing Issues: If cells are not balancing, check the sampling line connections for continuity and proper seating. Ensure the active balancing feature is enabled in the app or PC software.
- Over-protection Alarms: If the BMS triggers overcharge, over-discharge, or overcurrent alarms, check the battery voltage and current levels. Review and adjust the protection parameters in the mobile app or PC software if necessary.
- Communication Problems: For Bluetooth issues, ensure the app is updated and Bluetooth is enabled on your mobile device. For RS485/CAN/RS232, verify cable connections and correct protocol selection in the PC software or app.
- Temperature Alarms: Check the ambient temperature and ensure proper ventilation around the BMS and battery pack. Verify temperature sensor connections.
- Dry Contact Trigger: If using dry contact triggers, ensure they are correctly configured and the trigger source is functioning as expected. Alarm details will be displayed in the mobile app.
For persistent issues, refer to the detailed instruction manual (if provided separately) or contact technical support.
9. User Tips
- Always ensure all connections are tight and properly insulated to prevent short circuits and ensure safety.
- Before making any changes to the BMS settings, especially protection parameters, understand their implications for your battery pack. Incorrect settings can lead to battery damage or safety hazards.
- Utilize the mobile app for convenient monitoring and quick adjustments. Familiarize yourself with its interface and features.
- When connecting to an inverter, ensure the correct communication protocol is selected in the BMS settings to guarantee seamless operation.
10. Support
For further assistance, detailed instruction manuals, or technical inquiries, please contact JIKONG BMS Store customer support. You may also find additional resources and app download links on the official JIKONG website.