1. Introduction
The ATORCH DC5V 30A Relay Module is designed to work in conjunction with the ATORCH DT20W Meter to provide enhanced protection and control functionalities for various electrical testing scenarios. This module enables automatic power-off protection when voltage values fall below a low threshold or exceed a high threshold, safeguarding connected products.
Key functions include:
- Automatic power-off protection during battery testing when fully charged and power-off after discharging.
- Implementation of overvoltage, low-voltage, and power outage protection functions.
This relay module is suitable for testing various batteries, power adapters, constant current loads, and power banks.
2. Product Contents
The package includes the following items:
- 1 x DC 5V 30A Relay Module
- 1 x White connector cable
- 1 x Red wire
3. Setup
The relay module must be connected to a DT20W Meter and requires an independent 5V DC power supply for operation. Ensure all connections are secure before powering on the device.
3.1 Initial Power-up and Language Selection (DT20W Meter)
Before connecting the relay, ensure your DT20W Meter is powered and configured.
Video 1: Demonstrates connecting the DT20W meter to a USB 5V power supply, selecting the language (Chinese or English) using the '+' or '-' buttons, confirming with 'M', and navigating testing interfaces.
- Connect a USB 5V power supply to the DT20W Meter's power port.
- The device will power on and display a language selection screen.
- Use the "+" or "-" buttons to select your preferred language (Chinese or English).
- Press the "M" button to confirm your selection and enter the testing interface.
3.2 Wiring the Relay Module
The relay module must be powered independently by 5V DC. It is crucial that the independent power supply for the relay does not use the same circuit as the tested power supply to avoid interference and ensure proper protection.
- The relay should be connected to the output positive pole of the circuit you wish to control.
- If the battery is being charged, connect the input to a charger and the output to a fully charged battery. The relay will automatically disconnect to prevent overcharging.
Note: The instrument panel shown in the diagrams is for schematic purposes only and is not included with the relay module.
4. Operating Instructions
4.1 Navigating Testing Interfaces
Once the DT20W Meter is powered on and language is selected, you can switch between different testing interfaces.
- From the main testing interface, short press the "+" or "-" button to cycle through various display modes and data screens.
4.2 Controlling the Relay
The relay function allows you to manually or automatically control the power flow based on the DT20W Meter's settings.
- To manually turn the relay ON or OFF, long press the "+" button on the DT20W Meter.
- The DT20W Meter's display will indicate the current status of the relay (ON or OFF).
Note: The relay function is only available when the relay module is correctly connected to the DT20W Meter and configured.
4.3 Accessing System Settings
To configure advanced settings on the DT20W Meter, including calibration and prompt thresholds:
- Long press the "M" button on the DT20W Meter to enter the background settings menu.
- Navigate through the menu using the "+" and "-" buttons.
- Settings include Language Style, Display Brightness, Standby Brightness, Standby Time, Diverter size, External Temperature Calibration, Voltage/Current Calibration Reference, Overvoltage/Low-voltage/Overpower Prompts, Over Temperature Extension, Zero No-Load Current, HID/WiFi/Bluetooth settings, Zero All Data, Default Setting, Mini Measure Amp, and Exit.
5. Maintenance
The ATORCH DC5V 30A Relay Module is designed for durability and requires minimal maintenance. To ensure optimal performance and longevity:
- Keep the module clean and free from dust and debris.
- Avoid exposing the module to extreme temperatures or humidity.
- Periodically check all wiring connections to ensure they are secure and free from corrosion.
- If any soldering appears loose or dirty, it is recommended to have it inspected by a qualified technician.
6. Troubleshooting
If you encounter issues with your ATORCH DC5V 30A Relay Module, consider the following:
- Relay not activating/deactivating:
- Ensure the relay module has its own independent 5V DC power supply.
- Verify all wiring connections between the relay, DT20W Meter, and the load/battery are correct and secure.
- Check the DT20W Meter's settings for overvoltage/low-voltage thresholds and ensure they are configured appropriately for your application.
- Confirm the manual ON/OFF function by long-pressing the "+" button on the DT20W Meter.
- Inaccurate readings on DT20W Meter:
- Ensure the DT20W Meter is properly calibrated. Refer to the DT20W Meter's manual for calibration procedures.
- Module not powering on:
- Check the 5V DC power supply connection to the relay module.
- Ensure the power supply is providing the correct voltage and current.
If problems persist, contact customer support for further assistance.
7. Specifications
| Feature | Specification |
|---|---|
| Brand Name | ATORCH |
| Model Number | DC5V 30A Relay Module (for DT20W Meter) |
| Independent Power Supply Voltage | DC 5V |
| Working Current of Relay | 30A |
| DIY Supplies | Electrical |
| Operating Temperature | -20°C ~ +60°C |
| Certification | CE |
| Data Record | No (Relay module itself) |
| Battery Included | No |
| High-concerned chemical | None |
| Package Dimensions (L x W x H) | 5 cm x 5 cm x 5 cm (approx.) |
| Package Weight | 0.145 kg (approx.) |
8. User Tips
- Check Soldering: Some users have noted slightly dirty soldering. While generally functional, a quick visual check of the solder joints can ensure long-term reliability.
- BMS Compatibility: If your battery system already includes a Battery Management System (BMS), the relay module's protection features might be redundant. Evaluate your system's needs before integrating.
- Automation Potential: This relay module, when connected to the DT20W Meter, allows for the creation of automation routines based on voltage thresholds, enhancing your power management capabilities.
- Independent Power: Always remember to provide an independent 5V power supply to the relay module to ensure proper operation and prevent potential issues with the main circuit under test.
9. Warranty and Support
For any questions, technical support, or warranty inquiries, please contact the seller or manufacturer directly. Keep your purchase records for reference.