INVT CHF100A-2R2G-S2

INVT CHF100A Series Vector Universal Inverter

Model: CHF100A-2R2G-S2

1. Introduction

This manual provides essential information for the safe and efficient operation of the INVT CHF100A series vector universal inverter, specifically model CHF100A-2R2G-S2. This Variable Frequency Drive (VFD) is designed for industrial applications requiring precise motor control. It operates on a single-phase 220V power supply and is suitable for motors up to 2.2KW, offering both V/F open loop and vector control capabilities.

Front view of the INVT CHF100A-2R2G-S2 Inverter, showing the display panel, RUN/STOP buttons, and warning labels.
Figure 1: INVT CHF100A-2R2G-S2 Inverter Front Panel

2. Safety Information

WARNING: To prevent injury or electric shock, observe the following safety precautions:

  • Do not touch terminals until the DC bus capacitor has fully discharged.
  • Always follow the safety instructions provided in the complete instruction manual (if available).
  • Ensure proper grounding techniques are used during installation and operation.

Always disconnect power before performing any installation, wiring, or maintenance procedures. Only qualified personnel should install, operate, and maintain this equipment.

3. Product Overview

The INVT CHF100A-2R2G-S2 inverter features a robust design suitable for various industrial environments. The front panel includes a digital display for monitoring parameters and status, along with intuitive control buttons for operation (RUN, STOP) and navigation (directional arrows, ENTER). The unit is designed for efficient and reliable motor control.

4. Specifications

Key specifications for the CHF100A series inverters are provided below. Please refer to the table for details specific to your model.

Table showing specifications for various INVT CHF100A series inverter models, including input voltage, rated power, input current, output current, and compatible motor power.
Figure 2: INVT CHF100A Series Specifications Table

Model CHF100A-2R2G-S2 Specifics:

ParameterValue
Model No.CHF100A-2R2G-S2
Input VoltageSingle Phase 220V ±15%
Rated Power (kW)2.2
Rated Input Current (A)23.0
Rated Output Current (A)10
Compatible Motor (kW)2.2

General Properties:

  • DIY Supplies: Electrical
  • Origin: Mainland China
  • Certification: NONE

5. Setup and Wiring

Proper installation and wiring are critical for the safe and correct operation of the inverter. Ensure all power is disconnected before proceeding.

5.1 Power and Motor Connections

Connect the single-phase 220V AC power supply to the input terminals (typically R and S). Connect the motor to the output terminals (U, V, W). Ensure all connections are secure and correctly phased. A dedicated ground connection is mandatory for safety.

5.2 Control Terminal Connections

The inverter provides various control terminals for external commands, such as start/stop signals, speed reference, and fault indications. Refer to the detailed wiring diagram for specific terminal assignments and connection methods for your application.

Detailed wiring diagram for the INVT CHF100A series inverter, showing connections for power input (R, S, T), motor output (U, V, W), grounding, and various control terminals.
Figure 3: INVT CHF100A Series Wiring Diagram

The wiring diagram illustrates the connections for both power and control circuits. Pay close attention to the labeling of each terminal to avoid miswiring, which can lead to equipment damage or safety hazards.

6. Operating Instructions

The CHF100A inverter supports two primary control modes: V/F open loop control and vector control. The choice of control mode and specific parameters can be configured via the inverter's control panel.

6.1 Basic Operation

  1. Power On: After ensuring all wiring is correct and secure, apply power to the inverter.
  2. Parameter Setting: Use the navigation buttons and ENTER key on the front panel to access and adjust operational parameters. Consult the full product manual for a comprehensive list of parameters and their functions.
  3. Start/Stop: Press the green "RUN" button to start the motor and the red "STOP" button to halt operation. External control signals can also be configured for remote start/stop.
  4. Speed Adjustment: Adjust the motor speed using the designated speed reference input (e.g., potentiometer, analog input, or digital input via parameters).

6.2 Control Modes

  • V/F Open Loop Control: This mode is suitable for general-purpose applications where precise speed and torque control are not critical. It maintains a constant voltage-to-frequency ratio.
  • Vector Control: For applications requiring high performance, such as precise speed regulation, high starting torque, or fast response, vector control (also known as Field-Oriented Control) can be enabled and configured.

7. Maintenance

Regular maintenance ensures the longevity and optimal performance of your INVT CHF100A inverter.

  • Cleaning: Keep the inverter clean and free from dust and debris. Use a soft, dry cloth for cleaning. Do not use liquid cleaners.
  • Ventilation: Ensure adequate airflow around the inverter to prevent overheating. Regularly check that cooling fans are operating correctly and are not obstructed.
  • Terminal Check: Periodically inspect all wiring terminals for tightness and signs of corrosion. Loose connections can cause overheating and malfunction.
  • Environmental Conditions: Operate the inverter within its specified environmental conditions (temperature, humidity) to prevent damage.

8. Troubleshooting

This section provides solutions to common issues you might encounter. For more complex problems, consult a qualified technician or the manufacturer's support.

ProblemPossible CauseSolution
Motor not startingNo power, incorrect wiring, parameter error, emergency stop active.Check power supply, verify wiring, review parameter settings, ensure emergency stop is disengaged.
Overheat alarmInsufficient ventilation, blocked fan, excessive load.Ensure proper clearance, clean fan/heatsink, reduce motor load.
Motor runs erraticallyLoose motor connections, incorrect motor parameters, interference.Check motor wiring, verify motor parameters (e.g., rated current, frequency), check for electromagnetic interference.

9. User Tips

Based on common user experiences, here are some tips for optimizing your inverter's performance:

  • Always ensure the motor parameters (rated voltage, current, frequency) are accurately entered into the inverter settings for optimal performance and protection.
  • For applications requiring precise speed control, consider utilizing the vector control mode and performing an auto-tuning function if available, to match the inverter to your specific motor characteristics.
  • When experiencing unexpected behavior, first check all wiring connections for looseness or damage before adjusting parameters.

10. Warranty and Support

For warranty information, technical support, or service inquiries, please contact your authorized INVT distributor or the manufacturer directly. Keep your purchase receipt and product model number (CHF100A-2R2G-S2) readily available when seeking support.

The product is manufactured in Mainland China. For specific details regarding warranty periods and terms, refer to the documentation provided at the time of purchase or visit the official INVT website.

Related Documents - CHF100A-2R2G-S2

Preview AT1-2.2KW (220V) Single-Phase to Three-Phase Inverter Operating Instructions
Comprehensive operating instructions and technical specifications for the AT1-2.2KW (220V) single-phase to three-phase inverter, covering installation, wiring, control panel functions, parameter settings, and error codes.
Preview AT Series Inverter Operating Instructions - High Performance AC Motor Driver
Detailed operating instructions for the AT Simple general series Inverters (AT1, AT2, AT3), covering installation, wiring, terminal descriptions, operation panel, parameter specifications, and fault codes. Features high performance and low noise for mini AC motor drivers.
Preview V2 Series Small Power Universal AC Drive/VFD Operation Manual
Comprehensive operation manual for the V2 Series Small Power Universal AC Drive/VFD, detailing installation, wiring, operation, parameters, and troubleshooting for models ranging from 0.4KW to 7.5KW. Includes technical specifications, safety precautions, and application examples.
Preview VTS5000D Series Installation Manual - VTS Inverter Guide
Comprehensive installation manual for VTS5000D series inverters. Covers installation, wiring, specifications, parameters, and troubleshooting for VTS variable frequency drives.
Preview Huanyang GT Series Variable Frequency Drive (VFD) 0.75kW-2.2kW Technical Specifications
Detailed technical specifications, features, applications, and wiring diagrams for the Huanyang GT Series Variable Frequency Drive (VFD) models, including GT-1R5G-2, GT-2R2G-2, GT-0R7G-4, GT-1R5G-4, and GT-2R2G-4. Covers terminal descriptions, control functions, and physical specifications.
Preview INVT Goodrive20-UL Series VFD Operation Manual
This operation manual provides comprehensive guidance on the INVT Goodrive20-UL Series Variable Frequency Drive (VFD), covering safety, installation, operation, parameter settings, and troubleshooting for efficient motor control.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.