Hi-Link HLK-LD2402

Contents

HLK-LD2402 24G Millimeter Wave Radar Sensing Module User Manual

Brand: Hi-Link | Model: HLK-LD2402

1. Introduction

The HLK-LD2402 is a static human life sensor designed for precise detection of human presence, including motion and micro-motion. This module integrates a highly simplified 24 GHz sensor hardware with intelligent algorithm firmware. It features an AIoT millimeter wave sensor, high-performance 24 GHz transmitting and receiving antenna, and essential peripheral circuits. The human presence sensing algorithm utilizes millimeter-wave radar distance measurement technology and advanced proprietary radar signal processing to accurately perceive and report human presence in real-time within indoor environments.

2. Key Features

  • Equipped with a single-chip intelligent millimeter wave sensor SoC and intelligent algorithm firmware.
  • Ultra-small sensor size: 20 mm x 20 mm.
  • Load the default human body sensing configuration, enabling plug-and-play functionality.
  • Operates in the 24 GHz ISM band, compliant with FCC, CE, and Committee-free spectrum regulations.
  • Flexible power supply: 3.3 V, 5V, supporting a wide voltage range of 3.0 V ~ 3.6 V and 4.5 V ~ 5.5 V.
  • Low average working current: 50 mA.
  • Detects moving, fretting, and the presence of human bodies.
  • Reports detection results in real-time.
  • Maximum detection distance for human motion induction is 10 meters.
  • Wide detection angle, covering up to 60 degrees.
  • Supports various installation methods, including ceiling and wall mounting.
  • Independently configurable trigger and hold states, offering strong anti-interference capabilities.

3. Technical Specifications

HLK-LD2402 Module Specifications
ParameterValue
Model NumberHLK-LD2402
Brand Namebibikoo (Hi-Link)
OriginMainland China
Operating Frequency Band24-24.25GHz
Maximum Sweep Bandwidth0.25GHz
Supply Voltage3.0V-3.6V (also 4.5V-5.5V wide range)
Size20mm x 20mm
Detection Accuracy±0.15m
Average Working Current50 mA
Data Refresh Cycle165 ms
Communication MethodTTL Serial Communication
Camera EquippedNo
CompatibilityOthers
Transmitting Power13dBm
Detection Distance6m (adjustable)
Detection Angle±60°
Output TypeSerial protocol / High and low levels
Product Dimensions20*20mm
Operating Temperature-40℃ ~ 85℃
Radar Sensing Module Selection Table
Figure 3.1: Radar Sensing Module Selection Table, highlighting HLK-LD2402 specifications.

4. Setup and Connection

The HLK-LD2402 module is designed for straightforward integration. It features five pin holes (J2) for power supply and communication, and a separate J1 interface for MCU program burning and debugging. The pin spacing is compatible with both 2.54mm and 2.00mm jack spacing.

4.1 Pinout Diagram

HLK-LD2402 Pinout Diagram
Figure 4.1: Front and back view of the HLK-LD2402 module, showing J1 (SWD) and J2 (Power/Communication) pin labels.

J2 Interface (Power & Communication):

  • Pin 1 (V): Power Supply Input (3.0V-3.6V or 4.5V-5.5V)
  • Pin 2 (IO): General Purpose Input/Output (High/Low Level Output)
  • Pin 3 (GND): Ground
  • Pin 4 (TX): Serial Data Transmit
  • Pin 5 (RX): Serial Data Receive

J1 Interface (SWD): Used for MCU program burning and debugging. Specific pin functions for J1 are typically for advanced development and debugging, including SWDIO, SWCLK, Reset, and VCC/GND connections.

4.2 Connection Examples

The module can be connected using standard DuPont lines or integrated into a test kit for easier development.

HLK-LD2402 Test Kit-A
Figure 4.2: HLK-LD2402 module with 2.54mm DuPont lines (Test Kit-A).
HLK-LD2402 Test Kit-B
Figure 4.3: HLK-LD2402 module with DuPont lines and a USB-TTL converter (Test Kit-B) for PC communication.

5. Operation

The HLK-LD2402 module operates as a human body stationary micro-motion sensor, primarily communicating via TTL serial communication. It provides real-time detection results and can output high or low logic levels based on detection events.

5.1 Detection Principle

The module uses 24G millimeter wave radar technology to detect subtle movements, including micro-motion (like breathing) and static presence of a human body. The intelligent algorithm processes the radar signals to differentiate between various states of human presence.

5.2 Serial Communication (TTL)

Connect the module's TX and RX pins to a compatible TTL serial interface (e.g., a microcontroller's UART or a USB-TTL converter connected to a computer). The module will transmit detection data through its TX pin. Refer to the module's specific communication protocol documentation (not provided here) for details on data format and commands.

HLK-LD2402 TTL Serial Communication and IO Output
Figure 5.1: HLK-LD2402 highlighting TTL serial communication and IO high/low level output capabilities.

5.3 IO High and Low Level Output

The IO pin can be configured to provide a high or low logic level output based on detection events. This can be used to trigger external circuits or indicate presence/absence without needing to parse serial data. The specific behavior (e.g., high on detection, low on no detection) is typically configurable via the module's firmware settings.

5.4 Configuration

The module supports independent configuration of trigger and hold states. This allows for fine-tuning the sensitivity and response time to suit different application requirements and minimize false positives due to transient events. Configuration details are typically accessed via serial commands.

6. Maintenance

  • Cleaning: Keep the module clean and free from dust and debris. Use a soft, dry cloth for cleaning. Avoid using liquids or abrasive materials.
  • Environment: Operate the module within its specified operating temperature range (-40℃ to 85℃). Avoid exposure to extreme temperatures, high humidity, or corrosive environments.
  • Physical Damage: Handle the module with care to prevent physical damage to the PCB, antennas, or components.
  • Power Supply: Ensure a stable power supply within the specified voltage range (3.0V-3.6V or 4.5V-5.5V) to prevent damage.

7. Troubleshooting

Common Issues and Solutions
ProblemPossible CauseSolution
No detection or inconsistent detectionIncorrect power supply; Obstructions in detection area; Module not properly oriented; Environmental interference.Verify power supply voltage; Ensure clear line of sight for the module; Adjust module orientation for optimal coverage; Minimize sources of electromagnetic interference.
No serial data outputIncorrect wiring (TX/RX swapped); Incorrect serial port settings (baud rate, parity, stop bits); Module not powered on.Check TX/RX connections; Confirm serial port settings match module requirements; Ensure module is powered correctly.
IO output not respondingIO pin not configured correctly; External circuit issue; Module not detecting presence.Review firmware configuration for IO pin behavior; Check external circuit connections; Verify module is detecting presence via serial output.
False detectionsVibrations; Air currents; Nearby moving objects; High sensitivity settings.Mount the module securely to minimize vibrations; Avoid placing near fans or vents; Adjust sensitivity settings (trigger/hold states) via serial commands.

8. User Tips

  • For initial setup and testing, consider using a USB-TTL converter (like those found in Test Kit-B) to easily interface the module with a computer and monitor serial output.
  • Experiment with different mounting heights and angles to optimize the detection area for your specific application. The 60-degree detection angle provides flexibility.
  • If experiencing false positives, try adjusting the trigger and hold state parameters through serial commands. This can help filter out minor environmental disturbances.
  • Ensure the power supply is stable and within the recommended voltage range to guarantee reliable operation and prevent damage to the module.

9. Warranty and Support

For warranty information, technical support, or further inquiries regarding the HLK-LD2402 module, please contact Shenzhen Hi-Link Electronic Co., Ltd. directly. Refer to the seller's official website or contact details provided at the point of purchase for the most up-to-date support information.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.