Retekess TD112-TD036

Contents

Retekess TD112 Watch Receiver and TD036 Call Button User Manual

Wireless Restaurant Pager System

1. Product Overview

The Retekess TD112 Watch Receiver and TD036 Call Button form a wireless restaurant pager system designed for efficient communication in various service environments. The system features long-distance communication, low battery reminders, and multiple language options.

Retekess TD112 Watch Receiver and TD036 Call Buttons
Figure 1: Retekess TD112 Watch Receiver and TD036 Call Buttons
Retekess TD036 and TD112 Wireless Restaurant Pager features
Figure 2: Key Features of TD036 and TD112

Functional Diagram

Functional Diagram of TD112 Watch Receiver
Figure 3: Functional Diagram of TD112 Watch Receiver (A Button, B Button, LED Display, Charging/IO port)

2. Setup and Initial Configuration

Power On, Power Off, Wake Up

  1. Power On: In the off state, long press the 'B' button to turn on the watch. If it's the first time or after a factory reset, you will be prompted to set the watch pager's name and ID.
  2. Power Off: In the standby state, long press the 'B' button for about 3 seconds to turn it off.
  3. Wake Up: In sleep mode, press any key or when the pager receives an incoming call message, the screen will wake up and enter working mode.
  4. Call Confirmation and Delete: In working mode, short press any key to confirm and delete the received call.
  5. In some settings, pressing and holding the 'A' button can continuously increase the value.

Battery Instructions

The TD112 Watch Receiver has a built-in 180mAh lithium battery. The TD036 Call Button uses 2 AAA batteries.

TD036 Call Button with removable AAA batteries
Figure 4: TD036 Call Button with removable AAA batteries
  • The watch pager uses a special charging clip method. It takes about 3 hours to be fully charged.
  • The battery icon flashes while the watch pager is charging in Standby State.
  • It displays a power icon and the battery icon flashes while it is charging in the Off State.
  • The battery icon stops flashing when fully charged.
  • When the battery is low, the battery icon will flash on the screen.

Pairing Operation

The watch pager can pair up to 500 call buttons.

  1. In the standby state, press and hold (about 1s) the 'A' button to enter setting mode.
  2. Press the 'A' or 'B' button to select "Pairing".
  3. Press and hold (about 1s) the 'A' button to enter the sub-menu.

Ext Pair (Pairing with Call Buttons)

  1. Follow steps 1-3 above.
  2. Press the 'A' or 'B' button to select "Ext Pair".
  3. Press and hold (about 1s) the 'A' button to enter the sub-menu. It shows the ID number and ID status (e.g., Pair NO 0001).
  4. Press the 'B' button to move the edit position.
  5. Press the 'A' button to select the desired value (0-9, A-Z). Press and hold (about 1s) the 'A' button to delete the current paired ID.
  6. Press the call button that needs to be paired. The watch pager will vibrate and the status will change from "NO" to "OK". This pairing operation is completed. It will automatically go to the next ID for pairing a new call button.
  7. Press and hold (about 1s) the 'B' button to return to the setting menu after pairing all call buttons.

Ket Pair (Pairing with Keypad)

  1. Follow steps 1-3 above.
  2. Press the 'A' or 'B' button to select "Ket Pair".
  3. Press and hold (about 1s) the 'A' button to enter the sub-menu. It shows the Pager ID, Keypad Serial Number, and the status.
  4. Press the 'B' button to move the edit position.
  5. Press the 'A' button to select the desired value (Pager ID: 001-999, Keypad Serial Number: 01-50. "FFF" means the Keypad Serial Number is not registered and can be paired). Press and hold (about 1s) the 'A' button to delete the current paired ID.
  6. Press the corresponding Pager ID number on the keypad. The watch pager will vibrate and show "OK" on the display. The "FFF" will be changed to the Keypad ID. This pairing operation is completed.
  7. Press and hold (about 1s) the 'B' button twice to exit the setting mode.

Watch Pager PC Software

The user can change the watch pager's settings through software. You can download the Watch Pager Software and Instruction from the official Retekess website: https://www.retekess.com/resources/download

  1. Open the Watch Pager Software on PC.
  2. Connect the watch pager (must be in standby state) to the PC with the charging cable.
  3. Perform relevant operations in the software.
  4. Press "Write" after editing the desired value.

NOTE:

  • The original data will be overwritten when using the software to write data. It is recommended to export and save the original data before making settings.
  • The "Caller ID" can be obtained automatically by pressing the corresponding button when the Watch Pager and Software are connected.

Extended Function (Page Watch Pager from PC)

Connect the Retekess USB transmitter (model: TD030) to PC. The user can page the watch pager via Watch Pager Software. The USB transmitter needs to be purchased separately.

Retekess TD030 USB Transmitter
Figure 5: Retekess TD030 USB Transmitter (purchased separately)

3. Operating Instructions

General Operation

  1. In the standby state, press and hold (about 1s) the 'A' button to enter setting mode.
  2. Press the 'A' or 'B' button to select the desired value.
  3. Press the 'A' button for 1s to enter the sub-menu.
  4. Press the 'B' button for 1s to exit and save the current function setting.

Delete Received Call Information

When the watch pager receives calls, the received call information will be displayed in a loop (cycle interval is 5s, maximum 10 calls are cycled).

  1. Press and hold any key to delete all incoming calls and return to standby state.
  2. Press any key to delete the currently displayed call information.

Set Time

  1. In the standby state, press and hold (about 1s) the 'A' button to enter setting mode.
  2. Press the 'A' or 'B' button to select "Set Time".
  3. Press and hold (about 1s) the 'A' button to enter the sub-menu.
  4. Press the 'A' or 'B' button to select "Time".
  5. Press and hold (about 1s) the 'A' button to enter the time setting. It shows Hour and Minute (e.g., 13:12).
  6. Press the 'B' button to move the edit position among Hour, Minute, Year, Month, and Date.
  7. Press the 'A' button to select the desired value.
  8. Press and hold (about 1s) the 'B' button twice to exit the setting mode.

Alarm Setting (up to two alarms can be set)

  1. In the standby state, press and hold (about 1s) the 'A' button to enter setting mode.
  2. Press the 'A' or 'B' button to select "Set Time".
  3. Press and hold (about 1s) the 'A' button to enter the sub-menu.
  4. Press the 'A' or 'B' button to select "Alarm".
  5. Press and hold (about 1s) the 'A' button to enter the Alarm Setting. It shows the alarm times.
  6. Press the 'B' button to move the edit position.
  7. Press the 'A' button to select the desired value.
  8. Press and hold (about 1s) the 'B' button twice to exit the setting mode.

Powr T (Timer Switch Setting)

  1. In the standby state, press and hold (about 1s) the 'A' button to enter setting mode.
  2. Press the 'A' or 'B' button to select "Set Time".
  3. Press and hold (about 1s) the 'A' button to enter the sub-menu.
  4. Press the 'A' or 'B' button to select "Powr T".
  5. Press and hold (about 1s) the 'A' button to enter the Timer Switch Setting. It shows the automatic switch times.
  6. Press the 'B' button to move the edit position.
  7. Press the 'A' button to select the desired value.
  8. Press and hold (about 1s) the 'B' button twice to exit the setting mode.

NOTE:

The automatic shutdown function can only be performed in the standby state. When the automatic shutdown time is reached, the display will show "Auto Off", and the watch will vibrate twice to remind the user. The user can press any key to stop the automatic shutdown within 10s.

Prompt Setting (Vibration Time)

  1. In the standby state, press and hold (about 1s) the 'A' button to enter setting mode.
  2. Press the 'A' or 'B' button to select "Prompts".
  3. Press and hold (about 1s) the 'A' button to enter the sub-menu.
  4. Press the 'A' or 'B' button to select "Vibrate T".
  5. Press and hold (about 1s) the 'A' button to enter Vibration Time Setting. It shows the vibration status and prompt time (1-15 seconds).
  6. Press the 'B' button to move the edit position.
  7. Press the 'A' button to select the desired value.
  8. Press and hold (about 1s) the 'B' button twice to exit the setting mode.

Prompt Setting (Display Time)

  1. In the standby state, press and hold (about 1s) the 'A' button to enter setting mode.
  2. Press the 'A' or 'B' button to select "Prompts".
  3. Press and hold (about 1s) the 'A' button to enter the sub-menu.
  4. Press the 'A' or 'B' button to select "Display T".
  5. Press and hold (about 1s) the 'A' button to enter Display Time Setting. It shows the display time on the screen (00-10 minutes, 00 means calling information will never auto-clear).
  6. Press the 'B' button to move the edit position.
  7. Press the 'A' button to select the desired value.
  8. Press and hold (about 1s) the 'B' button twice to exit the setting mode.

Note:

The storage time of the call information is the vibration time plus the display time.

Working Mode Setting

There are 3 working modes available: General, Single Button, and Choose Receiver. General and Choose Receiver are compatible with each other while pairing. If the user changes from General or Choose Receiver to Single Button working mode, you need to operate the pairing again.

  1. In the standby state, press and hold (about 1s) the 'A' button to enter setting mode.
  2. Press the 'A' or 'B' button to select "Modes".
  3. Press and hold (about 1s) the 'A' button to enter the sub-menu.
  4. Press the 'A' or 'B' button to select the desired value.
  5. Press and hold (about 1s) the 'B' button twice to exit the setting mode.
  • General: Allows pairing with keypad and multi-key callers.
  • Single Button: Allows pairing any key from one multi-key caller with the watch pager. Each key from one multi-key caller can call a specific watch receiver if needed, and the key names received on the watch are the same.
  • Choose Receiver: Allows setting the watch to receive calls from specific keys from one multi-key caller. The user can set desired key names following the "Key Set" instruction.

Key Set (Set the Key Name)

  1. In the standby state, press and hold (about 1s) the 'A' button to enter setting mode.
  2. Press the 'A' or 'B' button to select "Key Set".
  3. Press and hold (about 1s) the 'A' button to enter the sub-menu. It shows the key name, serial number, and selection box.
  4. Press the 'A' or 'B' button to select the desired value.
  5. Press the corresponding key from the call button that needs to be defined. The serial number will become the key value at the same time, and the key set is completed.
  6. If using Watch Pager Software to set a custom key name, press 'A' and 'B' buttons simultaneously to switch between custom and default key names.
  7. In "Choose R" working mode, press and hold (about 1s) the 'A' button to select or cancel the selection.
  8. Press and hold (about 1s) the 'B' button twice to exit the setting mode.

NOTE:

Only one key name can be set for a key. It shows "FF" on the screen if there is no serial number for the key name. If the watch pager does not respond when the call button is pressed after pairing, refer to the above steps to set the key name, or set the key name through the Watch Pager Software. (When using the Watch Pager Software to custom the key name, the cancel button needs to be edited as "CANCEL").

Language Setting

TD112 Watch Receiver with 7 language options
Figure 6: TD112 Watch Receiver with 7 language options
  1. In the standby state, press and hold (about 1s) the 'A' button to enter setting mode.
  2. Press the 'A' or 'B' button to select "Language".
  3. Press and hold (about 1s) the 'A' button to enter the sub-menu.
  4. Press the 'A' or 'B' button to select the desired value (English, Chinese, Italian, Spanish, German, French, and Portuguese are available).
  5. Press and hold (about 1s) the 'B' button twice to exit the setting mode.

Name ID Setting

  1. In the standby state, press and hold (about 1s) the 'A' button to enter setting mode.
  2. Press the 'A' or 'B' button to select "Name ID".
  3. Press and hold (about 1s) the 'A' button to enter the sub-menu. It shows the Name and ID on the screen.
  4. Press the 'B' button to move the edit position.
  5. Press the 'A' button to select the desired value (ID: 001-999, Name: A-Z, a-z, space, up to 10 characters).
  6. Press and hold (about 1s) the 'B' button twice to exit the setting mode.

Note:

The user will be reminded to set the watch pager's name and ID when the device is turned on for the first time or after a factory reset. Press and hold (about 1s) the 'B' button to exit the setting mode.

Restore Factory Setting

Clear Pairing

  1. In the standby state, press and hold (about 1s) the 'A' button to enter setting mode.
  2. Press the 'A' or 'B' button to select "Default".
  3. Press and hold (about 1s) the 'A' button to enter the sub-menu.
  4. Press the 'A' or 'B' button to select "Clear".
  5. Press and hold (about 1s) the 'A' button to clear the pairing data. It shows "Clearing ..." on the screen.
  6. Press and hold (about 1s) the 'B' button twice to exit the setting mode.

Reset

  1. In the standby state, press and hold (about 1s) the 'A' button to enter setting mode.
  2. Press the 'A' or 'B' button to select "Default".
  3. Press and hold (about 1s) the 'A' button to enter the sub-menu.
  4. Press the 'A' or 'B' button to select "Reset".
  5. Press and hold (about 1s) the 'A' button to enter reset setting. It shows "Clearing ..." on the screen. The watch pager will automatically restart after the factory reset is completed.

4. Maintenance

Water Resistance

TD036 Call Button with IP55 Waterproof rating
Figure 7: TD036 Call Button with IP55 Waterproof rating
TD112 Watch Receiver with IPX7 Waterproof rating
Figure 8: TD112 Watch Receiver with IPX7 Waterproof rating
  • The TD036 Call Button is IP55 life waterproof, offering protection against splashing water or rain. It can be cleaned with a small amount of cold water.
  • The TD112 Watch Receiver is IPX7 waterproof, making it resistant to water immersion up to 1 meter for 30 minutes. This allows it to easily handle situations like juice or soup spills in a restaurant.

Battery Care

  • For TD036 Call Buttons, ensure to replace AAA batteries when the low battery indicator flashes.
  • For TD112 Watch Receiver, charge fully for approximately 3 hours using the provided charging clip.
  • Avoid exposing batteries to extreme temperatures.

Cleaning

  • Wipe the devices with a soft, damp cloth.
  • Do not use harsh chemicals or abrasive cleaners.
  • Ensure the charging port is dry before charging.

5. Troubleshooting

Pairing Issues

  • If the watch pager does not respond when the call button is pressed after pairing, verify the key name settings as described in the "Key Set" section, or use the Watch Pager Software to set the key name.
  • Ensure the cancel button is edited as "CANCEL" when customizing key names via software.

Automatic Shutdown

  • The automatic shutdown function only operates in standby mode.
  • If the watch displays "Auto Off" and vibrates, press any key within 10 seconds to stop the shutdown.

General Interference

  • If experiencing interference, try reorienting or relocating the receiving antenna.
  • Increase the separation between the equipment and other devices.
  • Connect the equipment to an outlet on a different circuit.
  • Consult the dealer or an experienced radio/TV technician for further assistance.

6. Specifications

ComponentFeatureSpecification
TD112 Watch ReceiverPrompting modeVibrate
Standby time48-72 hours
BatteryBuilt-in 180mAh lithium battery
Waterproof levelIPX7
Remind time1-15 seconds
Size48*25*15 MM
TD036 Call ButtonWorking frequency433.92MHz
Working voltage3V (two AAA batteries)
Indicator lightRed, Green
Range120-200m (open space)
ButtonsCall, Cancel
Size26*52*93 MM
General SystemStandby power consumption2.5mA
Adapter5V1A
Capacity450 call buttons + 50 keypads + 50 custom callers
Stored call information10
Communication Distance120-200m / 394-656ft (open space)

7. Warranty and Support

Warranty Information

Most new products carry a two-year manufacturer's warranty from the date of purchase. This guarantee card should be kept by the user, no replacement if lost.

Exclusions from Warranty Coverage:

  • Any product damaged by accident.
  • Misuse or abuse of the product, or as a result of unauthorized alterations or repairs.
  • If the serial number has been altered, defaced, or removed.

Customer Support

  • Contact the seller: For warranty and after-sales service, contact the seller where you purchased the product.
  • Local Repair Center: Products can be repaired by our Local Repair Center.
  • Proof of Purchase: For warranty service, you will need to provide a receipt proof of purchase from the actual seller for verification.
  • Online Resources: For a list of Retekess-approved accessories for your radio model, visit http://www.Retekess.com.

Regulatory Compliance and Safety

Before using this radio, read the safety guide which contains important operating instructions for safe usage and RF energy awareness and control for compliance with applicable standards and regulations.

RF Energy Exposure and Product Safety Guide

This radio uses electromagnetic energy in the radio frequency (RF) spectrum. Improper use can cause biological damage. All Retekess radios are designed, manufactured, and tested to meet government-established RF exposure levels. Specific operating instructions are provided to inform users about RF energy exposure and provide simple procedures for control.

For more information on RF energy exposure and control, refer to: http://www.who.int/en/

Local Government Regulations

Users must be fully aware of and able to control their exposure to meet occupational requirements. Your Retekess radio has an RF Exposure Product Label. The user manual includes information and operating instructions required to control RF exposure and satisfy compliance requirements.

Radio License (if appropriate)

Business radios operate on regulated radio frequencies. To transmit on these frequencies, a license issued by local radio management departments (FCC, ISED, OFCOM, ANFR, BFTK, Bundesnetzagentur...) may be required. Contact your local government radio management departments for detailed classification and use of your radios. Use of this radio outside the country where it was intended to be distributed may be prohibited.

Unauthorized Modification and Adjustment

Changes or modifications not expressly approved by the party responsible for compliance may void the user's authority to operate this radio. Transmitter adjustments should only be made by technically qualified personnel. Replacement of any transmitter component not authorized by local government radio management departments equipment authorization could violate the rules.

FCC Requirements:

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference.
  2. This device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

IC Requirements:

This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada's licence-exempt RSS(s). Operation is subject to the following two conditions:

  1. This device may not cause interference.
  2. This device must accept any interference, including interference that may cause undesired operation of the device.

RF Exposure Information (if applicable)

  • DO NOT operate the radio without a proper antenna attached, as this may damage the radio and may also cause you to exceed RF exposure limits.
  • DO NOT transmit for more than 50% of total radio use time, as this can cause RF exposure compliance requirements to be exceeded.
  • During transmissions, your radio generates RF energy that can possibly cause interference with other devices or systems. To avoid such interference, turn off the radio in areas where signs are posted to do so.
  • The device complies with RF specifications when used at 5mm from your body. Third-party belt-clips, holsters, and similar accessories used by this device should not contain any metallic components.
  • DO NOT operate the transmitter in areas that are sensitive to electromagnetic radiation such as hospitals, aircraft, and blasting sites.

Avoid Choking Hazard

The product contains small parts. Not for children under 3 years.

Protect your hearing

  • Use the lowest volume necessary to do your job.
  • Turn up the volume only if you are in noisy surroundings.
  • Turn down the volume before adding headset or earpiece.
  • Limit the amount of time you use headsets or earpieces at high volume.
  • When using the radio without a headset or earpiece, do not place the radio's speaker directly against your ear.
  • Use careful with the earphone, as excessive sound pressure from earphones and headphones can cause hearing loss.

Note: Exposure to loud noises from any source for extended periods of time may temporarily or permanently affect your hearing. The louder the radio's volume, the less time is required before your hearing could be affected. Hearing damage from loud noise is sometimes undetectable at first and can have a cumulative effect.

Avoid Burns

  • Do not use any portable radio that has a damaged antenna. If a damaged antenna comes into contact with the skin when the radio is in use, a minor burn can result.
  • When the conductive material such as jewelry, keys or chains touch exposed terminals of the batteries, may complete an electrical circuit (short circuit the battery) and become hot to cause bodily injury such as burns.
  • When the transceiver is used for long transmissions, the radiator and chassis will become hot.

Safety Operation

  • Do not use charger outdoors or in moist environments, use only in dry locations/conditions.
  • Do not disassemble the charger, that may result in risk of electrical shock or fire.
  • Do not operate the charger if it has been broken or damaged in any way.
  • Do not place a portable radio in the area over an air bag or in the air bag deployment area. The radio may be propelled with great force and cause serious injury to occupants of the vehicle when the air bag inflates.
  • Pull by the plug rather than the cord when disconnecting the charger.
  • Unplug the charger from the AC outlet before attempting any maintenance or cleaning.
  • Contact Retekess for assistance regarding repairs and service.
  • The adapter shall be installed near the equipment and shall be easily accessible.
  • Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries according to the instructions.
  • The plug considered as disconnect device of adapter.
  • The operating temperature of the EUT can't exceed the specified range.

8. User Tips

  • Optimal Placement: For best signal range, ensure the watch receiver is placed in an open area, avoiding obstructions. The TD036 call buttons can be easily attached to walls using EVA double-sided tape.
  • Battery Management: Keep spare AAA batteries for the TD036 call buttons to ensure continuous service. Monitor the low battery indicator to avoid service interruptions.
  • Language Customization: Utilize the 7 language options on the TD112 watch receiver to suit your staff's needs, improving communication efficiency.
  • Software for Advanced Settings: For complex configurations like custom key names or managing multiple pagers, use the Watch Pager PC Software. Remember to back up original data before making changes.
  • Water Protection: While the devices are waterproof (IP55 for TD036, IPX7 for TD112), avoid prolonged submersion or exposure to high-pressure water jets to maintain longevity.

9. Product Demonstration Video

Video: Product demonstration covering power on/off, pairing, alarm setting, language setting, time setting, timer switch setting, and prompt setting.

EU Importer: Germany Retevis Technology GmbH, Uetzenacker 29, 38176 Wendeburg

Henan Eshow Electronic Commerce Co., Ltd, 7/F, Sanjiang Building, No.170 Nanyang Road, Huiji District, Zhengzhou, Henan, China

Web: www.retekess.com

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.