WINAPEX 189 Series

Contents

WINAPEX 189 Series Digital Multimeter User Manual

Models: 189C, 189D, 189E

1. Introduction

This manual provides detailed instructions for the safe and effective operation of the WINAPEX 189 series digital multimeters (Models 189C, 189D, and 189E). Please read this manual carefully before using the product and keep it for future reference.

The WINAPEX 189 series multimeters are advanced, portable rotary dial digital multimeters designed for measuring AC/DC voltage, AC/DC current, resistance, capacitance, frequency, temperature, diode, and continuity. They feature a dual-integral A/D conversion core, an ultra-bright color screen with adjustable backlight, and a unique LCD turntable for easy function selection.

WINAPEX 189E Intelligent Rotary Dial Multimeter with 6000 counts and backlit screen, showing various measurement functions like Voltage, Current, Resistor, Capacitor, Continuity Test, and Auto mode.
Figure 1: WINAPEX 189E Intelligent Rotary Dial Multimeter

2. Model Differentiation

The WINAPEX 189 series offers three models with varying features:

  • 189C: Manual Range, Temperature Measurement.
  • 189D: Manual Range.
  • 189E: Auto Range, Variable Frequency Measurement, Temperature Measurement.
Comparison of WINAPEX 189C, 189D, and 189E multimeters, highlighting their key differences in ranging, temperature measurement, and variable frequency measurement.
Figure 2: Product Differentiation (189C, 189D, 189E)

3. Safety Information

Always observe safety precautions when using electrical testing equipment. Failure to do so may result in injury or damage to the meter or equipment under test.

  • Do not exceed the maximum input values for any measurement function.
  • Ensure the test leads are properly connected and the correct function is selected before making measurements.
  • Do not use the meter if it or the test leads appear damaged.
  • Exercise extreme caution when working with voltages above 30V AC RMS, 42V peak, or 60V DC. These voltages pose a shock hazard.
  • Replace the battery when the low battery indicator appears to ensure accurate readings.
  • Always disconnect the test leads from the circuit before changing the battery or opening the meter case.

4. Product Overview

The WINAPEX 189 series multimeters are designed for ease of use and accuracy. Key components include:

Diagram of the WINAPEX 189D multimeter showing its dimensions (150mm height, 75mm width, 20mm depth) and labeled parts: Turntable, Reverse screen, Function selection, Mute, Battery compartment, HOLD button, Flashlight/REL button, 20A current socket, COM common '-' polarity plug, VΩ polarity plug hole.
Figure 3: WINAPEX 189D Multimeter Overview and Dimensions
Diagram of the WINAPEX 189E multimeter showing its key operations: Turntable gear (adjustable clockwise/counter-clockwise), liquid crystal display, Function adjustment/Buzzer, Data HOLD/Brightness adjustment, AUTO mode, Function Adjustment/Frequency switching, Flashlight illumination/Relative value measurement, 20A current socket, COM common '-' polarity plug, Universal '+' polarity plug hole.
Figure 4: WINAPEX 189E Key Operations

4.1. Controls and Display

  • LCD Display: High brightness color screen, 5999 counts, automatic polarity display.
  • Rotary Dial (Turntable): Used to select measurement functions.
  • Power Button (Red): Turns the multimeter ON/OFF.
  • REL Button (Green): For relative value measurement and flashlight illumination (short press for relative value, long press for flashlight).
  • HOLD Button (Green): For data hold and brightness adjustment (short press for data hold, long press for brightness adjustment).
  • Function Adjustment/Frequency Switching Button (Green, left): For adjusting functions or switching frequency.
  • Function Adjustment/Buzzer Button (Green, right): For adjusting functions or activating the buzzer.
  • Input Jacks:
    • COM: Common terminal (negative).
    • VΩ: Input for voltage, resistance, capacitance, frequency, diode, continuity, and temperature measurements.
    • 20A: Input for high current (up to 20A) measurements.

5. Setup

5.1. Battery Installation

The multimeter requires 2 x 1.5V AA batteries (not included). To install or replace batteries:

  1. Ensure the multimeter is turned off and all test leads are disconnected.
  2. Locate the battery compartment on the back of the device (refer to Figure 3).
  3. Open the battery compartment cover.
  4. Insert two 1.5V AA batteries, observing the correct polarity.
  5. Close the battery compartment cover securely.

5.2. Connecting Test Leads

Connect the test leads to the appropriate input jacks based on the desired measurement:

  • For most measurements (voltage, resistance, capacitance, etc.), connect the black test lead to the COM jack and the red test lead to the VΩ jack.
  • For current measurements up to 20A, connect the black test lead to the COM jack and the red test lead to the 20A jack.

6. Operating Instructions

6.1. Power On/Off

Press the red Power button to turn the multimeter ON. Press and hold the Power button again to turn it OFF.

6.2. Function Selection

The WINAPEX 189 series features an innovative LCD rotary dial for function selection. Gently rotate the turntable clockwise or counter-clockwise to cycle through the available measurement modes. For models 189C and 189D (Manual Range), you will need to manually select the appropriate range. For model 189E (Auto Range), the meter will automatically detect the measurement type and range.

WINAPEX 189E multimeter in Auto Range mode, demonstrating one-key measurement without needing to shift gears, showing icons for Capacitor, Voltage, Resistance, Diode, and VFC.
Figure 5: Auto Range Function (Model 189E)
WINAPEX 189D multimeter in Manual Range mode, showing the rotary dial with various measurement functions like Buzzer, Diode, Current (mA, A), Voltage (V), NCV, Live, Temperature, and Hz.
Figure 6: Manual Range Function (Models 189C, 189D)

6.3. Basic Measurements

After selecting the desired function and connecting the test leads, apply the probes to the circuit or component to be measured. The reading will appear on the LCD display.

  • Voltage Measurement (AC/DC): Select the appropriate voltage mode (AC V or DC V) using the rotary dial. Connect the test leads in parallel to the circuit.
  • Current Measurement (AC/DC): Select the appropriate current mode (AC A or DC A). Connect the test leads in series with the circuit. Ensure the 20A jack is used for high current measurements.
  • Resistance Measurement: Select the resistance mode (Ω). Connect the test leads across the component.
  • Capacitance Measurement: Select the capacitance mode (F). Connect the test leads across the capacitor.
  • Frequency Measurement (Hz): Select the frequency mode (Hz). Connect the test leads to the signal source.
  • Temperature Measurement (189C/189E only): Select the temperature mode (°C/°F). Connect the thermocouple to the VΩ and COM jacks.
  • Diode Test: Select the diode mode. Connect the test leads across the diode.
  • Continuity Test: Select the continuity mode. Connect the test leads across the circuit. A buzzer will sound if continuity is detected.
  • NCV (Non-Contact Voltage) / Live Wire Recognition: Select NCV/Live mode. Bring the top of the meter close to the wire to detect AC voltage without contact.

Video 1: Demonstration of WINAPEX 189E Multimeter functions including display effects, auto measurement for resistance and voltage, VFC (variable frequency voltage) measurement, buzzer, diode test, and temperature measurement.

6.4. Special Functions

  • Data Hold: Short press the HOLD button to freeze the current reading on the display. Press again to release.
  • Backlight Adjustment: Long press the HOLD button to enter backlight adjustment mode. Each short press will cycle through brightness levels (0%, 20%, 40%, 60%, 80%, 100%).
  • Flashlight: Long press the REL button to turn the flashlight ON/OFF.
  • Mute Mode: Long press the right green button (Function Adjustment/Buzzer) to turn off the function prompt sound.
  • Image showing the brightness adjustment feature of the multimeter, with a slider indicating levels from 0% to 100%.
    Figure 7: Brightness Adjustment
    Image showing the mute mode feature of the multimeter, with a speaker icon crossed out, indicating the function prompt can be turned off by long pressing the right button.
    Figure 8: Mute Mode

7. Maintenance

  • Cleaning: Wipe the meter with a dry, soft cloth. Do not use abrasives or solvents.
  • Storage: If the meter is not used for a long period, remove the batteries to prevent leakage. Store in a cool, dry place.
  • Calibration: For optimal accuracy, periodic calibration by qualified personnel is recommended.

8. Troubleshooting

ProblemPossible CauseSolution
Meter does not power on.Dead or incorrectly installed batteries.Check battery polarity or replace batteries.
"OL" displayed on screen.Over-range condition or open circuit.Select a higher range (manual range models) or check for an open circuit.
Inaccurate readings.Low battery, incorrect function/range selected, or damaged test leads.Replace batteries, verify function/range, or inspect/replace test leads.
No sound in continuity mode.Mute mode is active.Long press the right green button to deactivate mute mode.

9. Specifications

The following table outlines the general specifications and measurement ranges for the WINAPEX 189 series multimeters. Please note that specific ranges may vary slightly between models (189C, 189D, 189E).

Function189C189D189E
RangeManual RangeManual RangeAuto Range
VFC (Variable frequency measurement)//√
Temperature-20~1000℃/-20~1000℃
DC Voltage600mv/6v/60v/600v/1000V600mv/6v/60v/600v/1000V6v/60v/600v/1000V
DC Current600mA/6A/20A6A/20A6A/20A
AC Voltage6v/60v/600v/750V6v/60v/600v/750V6v/60v/600v/750V
AC Current6A/20A6A/20A6A/20A
Resistance600Ω/6KΩ/60KΩ/600KΩ/6MΩ/100MΩ600Ω/6KΩ/60KΩ/600KΩ/6MΩ/100MΩ600Ω/6KΩ/60KΩ/600KΩ/6MΩ/100MΩ
Capacitors60nF/600nF/6uF/60uF/600uF/6mF/60mF60nF/600nF/6uF/60uF/600uF/6mF/60mF60nF/600nF/6uF/60uF/600uF/6mF/60mF
Frequency6Hz/60Hz/6KHz/60KHz/600KHz/6MHz/10MHz6Hz/60Hz/6KHz/60KHz/600KHz/6MHz/10MHz6Hz/60Hz/6KHz/60KHz/600KHz/6MHz/10MHz
AUTO Mode(ACV/DCV/Ω/Beep)(ACV/DCV/Ω/Beep)(ACV/DCV/Ω/Beep)
True RMS√√√
Diode√√√
Continuity√√√
NCV√√√
Live Wires Recognition√√√
Flashlight√√√
Brightness Adjustment√√√
Auto Power off√√√
Detailed specifications table for WINAPEX 189C, 189D, and 189E multimeters, listing functions like Range, VFC, Temperature, DC/AC Voltage, DC/AC Current, Resistance, Capacitors, Frequency, AUTO Mode, True RMS, Diode, Continuity, NCV, Live Wires Recognition, Flashlight, Brightness Adjustment, and Auto Power off.
Figure 9: Detailed Function Comparison and Specifications

General Specifications:

  • Name: Smart Rotary Dial Multimeter
  • Display mode: High brightness color screen display
  • Maximum display: 5999 (3 5/6) bit automatic polarity display
  • Measurement method: Dual integration A/D conversion
  • Sampling rate: Approximately 3 times per second
  • Function selection: LCD turntable rotation and key operation
  • Over range display: The highest bit displays "OL~"
  • Low voltage display: Supported
  • Working environment: (0~40) ℃, relative humidity <80%
  • Power supply: 2 * 1.5V AA batteries (not included)
  • Size: 153mm (L) x 70mm (W) x 33mm (H)
  • Weight: Approximately 200g

10. User Tips

  • For quick checks, especially for voltage and resistance, the Auto Range feature (Model 189E) simplifies operation by eliminating the need for manual range selection.
  • Utilize the backlight adjustment feature for clear readings in various lighting conditions.
  • The high-voltage diode output measurement is particularly useful for testing various types of LEDs.
  • Remember to long-press the REL button for the flashlight function when working in dimly lit areas.

11. Warranty and Support

For warranty information and technical support, please refer to the contact details provided with your purchase or visit the official WINAPEX website. Keep your purchase receipt as proof of purchase for warranty claims.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.