1. Introduction
The JIKONG JK-BD4A Series Smart Battery Management System (BMS) is an intelligent protection board designed for large-capacity series lithium battery packs. It integrates advanced features for optimal battery performance and safety.
Key functionalities include precise voltage acquisition, high-current active balancing, and comprehensive protection against overcharge, over-discharge, overcurrent, and over-temperature. The BMS also features a coulomb meter for accurate capacity tracking, Bluetooth communication for remote monitoring, and optional GPS for location tracking.
This BMS is compatible with various battery chemistries, including Lithium-ion, LiFePO4, and LTO, making it suitable for a wide range of applications such as small sightseeing vehicles, mobility scooters, shared cars, high-power energy storage systems, base station backup power supplies, and solar power stations.


1.1. Functional Characteristics
- LED Bluetooth status indicator
- APP Bluetooth remote operation
- Battery capacity calculation
- High precision voltage acquisition (±3mV)
- High precision current acquisition
- Support information screen display
- Accurate time logging
- Support RS485 (Optional)
- Support CAN (Optional)
- Support parallel function (Optional)
- Support alarm function (Optional)
- Support heating function (Optional)
- Support GPS communication
- Charge overcurrent protection
- Charge overvoltage protection
- Charge over temperature protection
- Low temperature protection during charge
- Discharge overcurrent protection
- Discharge undervoltage protection
- Discharge over temperature protection
- Short circuit protection
2. Specifications
The JIKONG JK-BD4A series BMS offers robust performance with various models supporting different current ratings and cell configurations. Below are the general and default parameters.

2.1. General Parameters (60A/80A Protection Board)
| Project | 60A Model | 80A Model | Unit |
|---|---|---|---|
| Supply voltage | 20-100 | 20-100 | V |
| Operating power consumption | <800 | <800 | mW |
| Operating temperature | -30-70 | -30-70 | °C |
| Maximum number of collection strings | 24 | 24 | String |
| Maximum balancing current | 0.4 | 0.4 | A |
| Maximum charging current | 60 | 80 | A |
| Maximum discharge current | 60 | 80 | A |
| Maximum instantaneous current | 120 | 150 | A |
| Maximum internal loop resistance | 1.53 | 1.2 | mΩ |
| Protective plate size | 136*103*17.6 | 136*103*17.6 | mm |
| Finished weight | 260 | 260 | g |
2.2. Default Parameters
The following table outlines the default parameters for various battery types (Li-ion, LiFePO4, LTO) for the JK-BD4A series BMS. These values can be adjusted via the APP.
| Parameter | Li-ion (Default) | LiFePO4 (Default) | LTO (Default) | Unit |
|---|---|---|---|---|
| Balancing initial voltage | 3 | 3 | 2 | V |
| Maximum balancing current | 0.4 | 0.4 | 0.4 | A |
| Unit overcharge voltage | 4.2 | 3.6 | 2.7 | V |
| Single overcharge protection recovery | 4.18 | 3.55 | 2.65 | V |
| Monomer undervoltage protection | 2.82 | 2.6 | 1.8 | V |
| Single undervoltage protection recovery | 2.85 | 2.65 | 1.85 | V |
| Automatic shutdown voltage | 2.8 | 2.5 | 1.7 | V |
| SOC-0% voltage | 2.9 | 2.6 | 1.85 | V |
| SOC-100% voltage | 4.18 | 3.5 | 2.65 | V |
| Trigger balancing differential pressure | 0.01 | 0.01 | 0.01 | V |
| Charging overcurrent protection delay | 30 | 30 | 30 | S |
| Charge overcurrent protection release time | 60 | 60 | 60 | S |
| Discharge overcurrent protection delay | 300 | 300 | 300 | S |
| Discharge overcurrent protection release time | 60 | 60 | 60 | S |
| Short-circuit protection delay | 5 | 5 | 5 | µS |
| Short circuit protection release time | 30 | 30 | 30 | S |
| Charging overtemperature protection temperature | 70 | 70 | 70 | °C |
| Charge overtemperature restore temperature | 60 | 60 | 60 | °C |
| Discharge overtemperature protection temperature | 70 | 70 | 70 | °C |
| Discharge overtemperature recovery temperature | 60 | 60 | 60 | °C |
| Charging low temperature protection temperature | -20 | -20 | -20 | °C |
| Charge low temperature to restore temperature | -10 | -10 | -10 | °C |
| MOS Overtemperature protection temperature | 100 | 100 | 100 | °C |
| MOS Overtemperature protection recovery temperature | 80 | 80 | 80 | °C |
| Device address | 0 | 0 | 0 | / |
3. Installation
3.1. Packing List
Before installation, please verify that all components are present in the package:
- BMS x 1
- Switch x 1 (long 50cm)
- NTC x 1 (long 40cm)
- Sampling line B x 1 (long 70cm)
- Sampling line A x 1 (long 70cm)

3.2. Product Appearance and Dimensions
The BMS features a robust design with an aluminum alloy shell for excellent heat dissipation and protection against external environmental damage, including anti-voltage and anti-vibration properties.

The main BMS unit has dimensions of 136mm × 103mm × 17.6mm.
3.3. Interface Definition
The BMS is equipped with various interfaces to meet daily needs, including CAN, RS485, Bluetooth (BT), NTC, Soft Switch, SOC Indicator, Key Switch, and Active Equalizer. Specific ports are available for GPS, NTC, CAN, RS485, Heating, Sampling Port B, Sampling Port A, and Display/Switch Key.

The following table details the pin definitions for the main connectors:
| Connector | Pin Number | Name | Definition |
|---|---|---|---|
| HY2.0-15P (Balance & Acquisition) | 1 | B- | Total negative battery |
| 2 | B1 | The first battery positive | |
| 3 | B2 | The second battery positive | |
| 4 | B3 | The third battery positive | |
| 5 | B4 | The fourth battery positive | |
| 6 | B5 | The fifth battery positive | |
| 7 | B6 | The sixth battery positive | |
| 8 | B7 | The seventh battery positive | |
| 9 | B8 | The eighth battery positive | |
| 10 | B9 | The ninth battery positive | |
| 11 | B10 | The tenth battery positive | |
| 12 | B11 | The eleventh battery positive | |
| 13 | B12 | The twelfth battery positive | |
| 14 | B13 | The thirteenth battery positive | |
| 15 | B14 | The fourteenth battery positive | |
| HY2.0-11P (Balance & Acquisition) | 1 | B15 | The fifteenth battery positive |
| 2 | B16 | The sixteenth battery positive | |
| 3 | B17 | The seventeenth battery positive | |
| 4 | B18 | The eighteenth battery positive | |
| 5 | B19 | The nineteenth battery positive | |
| 6 | B20 | The twentieth battery positive | |
| 7 | B21 | The twenty-first battery positive | |
| 8 | B22 | The twenty-second battery positive | |
| 9 | B23 | The twenty-third battery positive | |
| HY2.0-4P (Temperature Interface) | 1 | T1A | First temperature sensor pin A |
| 2 | T1B | First temperature sensor pin B | |
| HY2.0-4P (4 external Temperature Interface) | 1 | T3A | Third temperature sensor pin A |
| 2 | T3B | Third temperature sensor pin B | |
| 3 | T4A | Fourth temperature sensor pin A | |
| 4 | T4B | Fourth temperature sensor pin B | |
| 1.25T-4PWT (GPS Interface) | 1 | VGPS | Power output, voltage close to B+ |
| 2 | TX | UART TX, 3.3V | |
| 3 | RX | UART RX, 3.3V | |
| 4 | GND | Power/signal ground | |
| A1254WF-2A (Buzzer Optional) | 1 | VCC | Buzzer power supply positive |
| 2 | GND | Buzzer power negative | |
| A1254WF-4A (Communication Interface) | 1 | RS485 B | Negative terminal of RS485 signal |
| A1254WF-6A (Display Interface) | 1 | VCC | Display power output |
| 2 | A | Display RS485 signal positive | |
| 3 | B | Display RS485 signal negative | |
| 4 | GND | Power negative terminal | |
| 5 | K+ | Activate the positive signal | |
| 6 | K- | Activate the negative signal electrode | |
| A1254WF-3A (Parallel Interface) | 1 | GND | Signal ground |
| 2 | P-EN | Parallel module enable signal, output low level to turn on parallel module | |
| 3 | P-status | Parallel module status signal | |
| 16AWG (Heating wire) | 1 | HT- | Heater element negative electrode |
3.4. Wiring Diagrams
The JK-BD4AxxS-6P/8P series protection board is suitable for 7-24 series lithium battery packs. The specific wiring method varies depending on the number of cells. Always ensure all cables are connected correctly and securely before powering on the BMS.
General Wiring Steps:
- Connect all balance cables to the battery cells, ensuring correct polarity and sequence.
- Insert the balance cable connector into the BMS.
- Connect the B-line (total negative electrode) and the P-line (total positive electrode) to the battery.
- Connect the load and charger to the designated P- and B- terminals.








4. Operation
4.1. Device Activation
Before powering on the protection board, ensure all balance cables are properly connected and that the P- and B- terminals are correctly wired. Verify that the protection board is securely fixed to the battery core. Incorrect connections can lead to abnormal operation or damage.
The BMS does not have a power-on control switch. It is designed for charging activation: the charger voltage must be 2V higher than the battery voltage. Once the battery assembly is complete, connect the charger to activate the protection board.
Alternatively, the BMS supports key activation and display activation. If you have an optional display screen and button, simply insert the cable into the display interface and press the button to activate.
4.2. APP Installation and Parameter Setting
The JIKONG BMS features a mobile APP compatible with Android, iOS, and HarmonyOS. The APP allows you to monitor battery status, modify working parameters, and control charge/discharge switches.
To install the APP, scan the QR code below. An Android version 7 or higher is required for Android devices.

After installing the APP, connect to the BMS via Bluetooth. You can then access the parameter settings to adjust values such as overcharge, over-discharge, overcurrent, temperature, and balance. Refer to the detailed 'Instructions for Setting Protection Board Parameters' in the full user manual (PDF) for comprehensive guidance.


4.3. Active Equalization
The BMS utilizes energy transfer active balancing technology to transfer energy from high-voltage cells to low-voltage cells, ensuring battery consistency and prolonging lifespan. The default balancing current is 0.4A, which can be adjusted via the APP based on battery capacity (recommended not to exceed 0.2C). The balancing function automatically activates when the cell voltage difference exceeds the set trigger value and deactivates when it falls below the threshold.

4.4. Heating Function (Optional)
For low-temperature environments, the BMS supports an optional heating function using a resistance heater or heating film. This prevents reduced battery activity and charging/discharging issues due to cold. The designed heating current is 10A. Users can enable/disable this function via the APP and should consider adding a temperature control switch (45°C to 65°C normally closed) in the heating circuit as a secondary safety measure.4.5. Communication Function (Optional)
The BMS supports optional CAN and RS485 communication functions. Users can configure the address and communication protocol via the APP to suit their specific requirements and scenarios. Refer to the Jikong Protection Board communication protocol document for detailed information.

5. Maintenance
To ensure the longevity and optimal performance of your JIKONG Smart BMS, regular maintenance and proper handling are essential:
- Environmental Conditions: Operate the BMS within the specified temperature range (-30°C to 70°C). If operating in extremely cold conditions, utilize the optional heating function to protect the battery cells.
- Physical Inspection: Periodically inspect the BMS and its connections for any signs of physical damage, loose wiring, or corrosion. The aluminum alloy shell provides robust protection, but external impacts should be avoided.
- Software Monitoring: Regularly check battery parameters and system status via the mobile APP or PC software. This allows for early detection of any anomalies in voltage, current, or temperature.
- Parameter Adjustment: Only adjust parameters via the APP or PC software if you understand the implications of the changes. Incorrect settings can affect battery performance and safety.
- Firmware Updates: Keep the BMS firmware updated to the latest version to benefit from performance improvements and bug fixes. Information on updates can be found on the official JIKONG website or through the APP.


6. Troubleshooting
The JIKONG Smart BMS is designed with multiple protection features to ensure safe operation. If an issue occurs, the BMS will trigger a protection state. Understanding these states can help in troubleshooting.
6.1. Common Protection Triggers and Solutions
- Overcharge Protection: Triggered when any cell voltage exceeds the set overcharge voltage. The BMS will stop charging. Charging will resume when all cell voltages drop below the recovery voltage.
- Over-discharge Protection: Triggered when any cell voltage drops below the set undervoltage protection. The BMS will stop discharging. Discharging will resume when all cell voltages rise above the recovery voltage. If any cell drops below the automatic shutdown voltage, the BMS will shut down.
- Overcurrent Protection (Charge/Discharge): Triggered if the charging or discharging current exceeds the set continuous current for a specified delay. The BMS will stop the respective operation. It will resume after the overcurrent release time. Ensure the maximum continuous discharge current does not exceed the design value (60A/80A).
- Overtemperature Protection: Triggered if the BMS detects temperatures above the set limits during charge or discharge. The BMS will stop the respective operation and resume when temperatures return to safe levels.
- Low Temperature Protection (Charge): Triggered if the temperature falls below the set low temperature limit during charging. The BMS will stop charging and resume when temperatures rise above the recovery limit.
- Short Circuit Protection: Triggered by a sudden high current spike. The BMS will stop operation. If this occurs during initial load connection, increasing the short circuit protection delay in the APP may resolve it, as some loads have large capacitance causing high instantaneous current.
6.2. Emergency Switch
The BMS includes an emergency switch function. If issues like over-temperature, over-discharge, overcharge, or cell string drops occur during normal use, activating the emergency switch via the APP's BMS control page will enable both charging and discharging for 30 minutes. This provides a critical window for emergency use, even if a single cell reaches its automatic shutdown voltage, preventing unexpected breakdowns.6.3. Intelligent Sleep
The intelligent sleep function allows the BMS to enter a low-power standby mode (when charge/discharge current is less than 1A for 26 consecutive hours) to reduce self-consumption. To reactivate the BMS, you can use the activation button or connect a charger.
7. User Tips
- Verify Wiring: Always double-check all balance leads and main power connections (P- and B-) before powering on the BMS to prevent damage.
- Monitor via APP: Regularly use the JIKONG Smart BMS APP to monitor your battery's health, including individual cell voltages, total voltage, current, and temperature. This helps in proactive maintenance.
- Cold Weather Operation: If operating in cold climates, ensure the optional heating function is enabled and properly configured to maintain optimal battery performance and prevent charging issues.
- Parameter Customization: While default parameters are suitable for most applications, experienced users can fine-tune protection values via the APP for specific battery types or usage scenarios. Always understand the impact of changes before applying them.
8. Warranty and Support
For warranty information, technical support, or service inquiries, please contact your seller or the manufacturer directly. Ensure you retain your proof of purchase for any warranty claims.
For detailed technical specifications, advanced parameter settings, and communication protocols, please refer to the official JIKONG Protection Board user manual PDF: JIKONG Lithium Battery Active Balance Protection Board Maintenance Manual (PDF).