1. Product Overview

The Bykski Granzon GFM III is a digital display DDC water cooling pump designed for PC liquid cooling loops. It features wireless speed adjustment, a ceramic bearing sleeve, and a maximum lift head of 6 meters. The pump is equipped with a 2-inch real-time display screen for monitoring various parameters.

Bykski Granzon GFM III DDC Pump with digital display
Bykski Granzon GFM III Digital Display DDC Pump

2. Safety Information

  • This pump supports only 12V DC power supply via a large 4D interface. Connecting power supplies with higher or lower voltage will damage the internal drive circuit and void all warranty services.
  • Use only purified water, ethylene glycol, propylene glycol, fluorinated liquid, or low-viscosity mineral oil as coolants. Corrosive, acidic, alkaline, conductive, or high-viscosity oils are strictly forbidden as they can abrade the ceramic shaft sleeve and corrode internal metal flow channels.
  • Never run the pump without coolant in the loop. Dry operation will cause instant overheating damage to the ceramic bearing and motor coil, which is not covered by free warranty repair.
  • The maximum allowable operating water temperature is 60°C. Do not use the pump in environments where coolant temperature exceeds this limit, as high temperatures accelerate the aging of rubber sealing rings and can lead to fluid leakage.
  • Do not drop, impact, disassemble, or modify the pump housing and display module without official authorization. Internal precision electronic components and ceramic shaft sleeves are vulnerable to deformation and damage from external impact.
  • The displayed Flow value is simulated data based on RPM and should not be used as a precise industrial flow measurement.
  • Avoid installing the pump in a fully closed space without ventilation. Continuous high-load operation with poor heat dissipation can trigger automatic overheat protection and affect cooling loop stability.
  • Keep small metal screws and electronic parts away from children to prevent pinching injuries or accidental swallowing.

3. Specifications

FeatureDescription
Model NumberGFM III
TypeDDC Pump Kit
Shaft StructureWear-resistant ceramic shaft sleeve
BearingCeramic
Maximum Lift Head6 Meters
Power Supply Standard12V DC, Large 4D power interface
Control ModeManual speed adjustment (wireless), Motherboard PWM automatic speed regulation
Display Screen2-inch HD digital display (Yes)
RGB SupportNO RGB
Dimensions (Front Panel)62.00mm x 62.00mm
Dimensions (Pump Body Thickness)40.30mm (Excluding Thread Screws)
CompatibilityStandard G1/4 thread interface, compatible with mainstream PC liquid cooling radiators, water blocks, reservoirs, hard/soft tubes.
OriginMainland China
CertificationNONE
Dimensions of the Bykski Granzon GFM III DDC Pump
Pump Dimensions (Front: 62x62mm, Thickness: 40.3mm)

4. Setup

4.1 Pre-installation Check

  1. Inspect the pump housing, display screen, thread ports, and rubber sealing rings for any scratches, cracks, or deformation. If any damage is found, do not proceed with installation and contact Granzon EU after-sales support.
  2. Prepare qualified coolant that matches the allowed liquid list (see Safety Information).
  3. Clean the entire cooling loop, including the reservoir, tubes, and radiators, to remove any metal debris, dust, or impurities that could cause bearing abrasion.

4.2 Hardware Installation

  1. Connect the pump's G1/4 thread ports to your liquid cooling tubes/reservoir using matched G1/4 fittings. Evenly tighten the connectors without excessive force to prevent thread sliding and coolant leakage.
  2. Plug the large 4D power cable into the pump's power interface. Connect the other end to a PC power supply 12V large 4D output port. Ensure sufficient wire length to avoid pulling the pump body during chassis vibration.
  3. Fix the pump onto a chassis pump bracket using matching screws. Place a vibration damping pad between the pump and the bracket to reduce operational noise.

5. Operation

5.1 Display & Speed Mode Operation

  1. After powering on the PC, the 2-inch screen on the pump will light up automatically, displaying RPM, Flow, Voltage, and Load data synchronously.
  2. Switch Mode Operation:
    • Manual Mode: Activate manual mode to adjust the pump rotation speed using wireless control. RPM can be increased or decreased in 100 RPM steps, with a maximum limit of 4800 RPM.
    • PWM Auto Mode: Switch to automatic mode. The pump will receive a PWM signal from the motherboard fan header and automatically adjust RPM based on CPU/GPU temperature feedback.

5.2 Display Screen Area Definition

LabelNameFunction Explanation
ARPMReal-time display of pump motor rotation speed (0-4800 RPM maximum)
BManual Mode IndicatorIndicates manual speed mode (adjust RPM in 100 RPM increments) or automatic PWM mode (auto adjust speed following motherboard PWM signal)
CFlow (Simulated)Analog flow value calculated by current RPM; higher precision when loop water resistance is lower, not actual measured flow
DVoltageReal-time input working voltage of the pump (nominal 12V)
ELoadReal-time motor operating load percentage (0-100%)
Bykski Granzon GFM III DDC Pump display modes showing RPM, Flow, and Load at different speeds
Display showing various RPM, Flow, and Load values

6. Maintenance

  • Daily Monitoring: Regularly observe the Load and RPM data. If the Load remains above 90% for an extended period, shut down the PC and inspect the cooling loop for blockages, air accumulation, or abnormal pipeline resistance.
  • Coolant Replacement: When replacing coolant, fully power off the pump and drain all residual liquid. Never disassemble the pump body with liquid remaining inside to avoid short circuits in the display electronics.
  • System Cleaning: Periodically clean the entire cooling loop, including the reservoir, tubes, and radiators, to prevent the buildup of metal debris, dust, and impurities that can cause bearing abrasion.

7. Troubleshooting

  • Pump Not Powering On: Ensure the pump is connected to a stable 12V DC power supply via the large 4D interface. Incorrect voltage will damage the internal circuitry.
  • High Load/Reduced Performance: If the display shows a Load consistently above 90%, check for blockages in the cooling loop, air bubbles, or excessive resistance in the tubing. Address these issues to prevent motor overload.
  • Pump Overheating: Ensure the pump is not running dry (without coolant). Dry operation causes rapid overheating and damage. Also, ensure adequate ventilation around the pump and avoid installing it in fully closed spaces.
  • Inaccurate Flow Readings: Remember that the displayed flow value is simulated. If you suspect issues with actual flow, check for physical obstructions or pump performance rather than relying solely on the simulated value for precise diagnostics.
  • Pump Damage After Installation: If damage is discovered during pre-installation check, do not proceed and contact support. Damage from improper installation or use of forbidden coolants may void warranty.

8. User Tips

  • Compatibility Check: Before purchasing or installing, carefully check the pump's dimensions (62x62x40.3mm) to ensure it fits your PC case and cooling setup, especially if using a distribution plate.
  • Avoid Continuous Max Speed: Do not run the pump at its full 4800 RPM continuously for more than 8 hours, as prolonged maximum speed operation can significantly shorten the ceramic bearing's service life.
  • Environmental Conditions: Maintain an ambient working temperature between 0°C and 45°C. Placing the pump near heating components with temperatures exceeding 60°C can damage the digital display screen.
  • Leak Testing: After full pipeline assembly and filling with coolant, exhaust all internal air bubbles. Perform a 12-hour offline leak test before formally starting your PC.

9. Warranty and Support

This product is designed for consumer PC liquid cooling systems. Industrial fluid transportation, chemical liquid circulation, and outdoor harsh environment use are prohibited and will void the warranty.

Warranty services may be voided if:

  • The pump is connected to power supplies with voltage higher or lower than 12V.
  • The pump is run dry (without coolant), causing overheating damage.
  • The pump housing or display module is disassembled or modified without official authorization.
  • Corrosive, acidic, alkaline, conductive, or high-viscosity oils are used as coolants.

For further assistance or to report product damage, please contact Granzon EU after-sales support.

A detailed user manual in PDF format is available for download: View User Manual (PDF)

© 2023 Bykski. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.