1. Introduction
The BSIDE ADMS1/ADMS1CL is a compact, dual-mode smart digital multimeter designed for ease of use and versatility. It combines the functions of a voltage detector and a multimeter, making it a convenient tool for various electrical measurements. Its automatic identification feature simplifies operation, allowing the device to detect tested parameters and select the appropriate range.
The ADMS1 model features a traditional LCD display, suitable for outdoor use where sunlight might affect visibility. The ADMS1CL model, on the other hand, is equipped with an EBTN screen, offering superior clarity in indoor or low-light environments.

Figure 1: BSIDE ADMS1 Multimeter in use for non-contact voltage detection.

Figure 2: Display comparison between ADMS1CL (EBTN) and ADMS1 (LCD) models.
2. Setup
2.1 Package Contents
Before starting, please verify that all items are present in your package:
- 1 x Smart Digital Multimeter (ADMS1 or ADMS1CL)
- 1 x Test Leads (Red and Black)
- 1 x Nylon Lanyard
- 1 x User Manual (this document)

Figure 3: Typical package contents including multimeter, test leads, and manual.
2.2 Battery Installation
The multimeter requires one AAA battery (not included in the package due to aviation security regulations). To install the battery:
- Locate the battery compartment cover on the back of the device.
- Use a screwdriver to open the battery compartment.
- Insert one AAA 1.5V battery, ensuring correct polarity (+/-).
- Close the battery compartment cover and secure it with the screw.
Video 1: Product unboxing and battery installation demonstration.
2.3 Connecting Test Leads
For measurements requiring direct contact, connect the test leads to the input terminals:
- Insert the black test lead into the "COM" (Common) input terminal.
- Insert the red test lead into the "INPUT" terminal.

Figure 4: Multimeter with red and black test leads connected to input terminals.
2.4 ZT-E8 Socket Set (Optional Accessory)
If you have purchased the ADMS1CL with the ZT-E8 socket set, please ensure you select the correct socket type for your region. Available types include EUR-220V, USA-110V, and UK-230V. If no specific type is noted during purchase, the EUR-220V will be sent by default.

Figure 5: Available ZT-E8 socket types.
3. Operating Instructions
3.1 Power On/Off
- Power On: Press the red power button (U) to turn on the device. The meter will display "AUTO" mode, indicating it's ready for automatic parameter identification.
- Power Off: Long press the red power button (U) to turn off the device.
3.2 Automatic Measurement (AUTO Mode)
In AUTO mode, the multimeter automatically identifies and measures AC voltage, DC voltage, or resistance. It also displays the AC signal frequency value when applicable.
- Ensure the test leads are correctly connected (Black to COM, Red to INPUT).
- Place the test leads in parallel across the circuit, power supply, or component to be tested.
- The meter will automatically detect the type of measurement (AC Voltage, DC Voltage, Resistance) and display the result on the screen.
- Observe the analog bar on the display for dynamic changes in the measured value.

Figure 6: Examples of measurements including AC Voltage, DC Voltage, and Resistance.
3.3 Specific Measurement Functions
While in AUTO mode, you can switch to specific functions using the blue button (M) for mode selection or the flashlight button.
- AC Voltage (V~) / DC Voltage (V=): The meter automatically detects and displays AC or DC voltage. Max input 400V.
- Resistance (Ω): Measures resistance up to 10MΩ.
- Frequency (Hz): Measures frequency from 40Hz to 1000Hz.
- Continuity: If the resistance between the test leads is less than 30Ω, the beeper will sound, indicating continuity.
- Non-Contact Voltage (NCV) / Live Wire Detection (V~Alert):
- Bring the non-contact voltage sensor at the top of the meter close to the object being tested (e.g., a power outlet or wire).
- The meter will detect AC voltage in the range of 90V~1000V AC (or 6V~1000V AC for specific modes).
- The voltage signal indicator lights (Green, Yellow, Red) and the buzzer alarm will indicate the strength of the detected voltage:
- Low-range (Green): 1/3 analog bar, slow alarm.
- Mid-range (Yellow): 2/3 analog bar, quick alarm.
- High-range (Red): Full analog bar, very loud alarm.

Figure 7: NCV detection on a power outlet.
- Live Wire in Wall Detection:
- Long press the blue button (M) to switch to Live Wire in Wall detection mode.
- Place the non-contact voltage sensor near the wall. The meter can detect hidden live wires up to 5cm deep.
- The closer to the live AC voltage line, the higher the bar value, the more frequent the buzzer alarm, and the voltage signal indicator will light up.

Figure 8: Detecting live wires within a wall.
- Flashlight: Short press the blue button (M) to turn the flashlight on or off. This is useful for working in dark environments.

Figure 9: Multimeter's flashlight function in use.
Video 2: Demonstration of various measurement functions and features.
4. Maintenance
- Cleaning: Wipe the device with a dry, soft cloth. Do not use abrasive cleaners or solvents.
- Battery Replacement: Replace the AAA battery when the low battery indicator appears on the display to ensure accurate readings. Follow the battery installation steps in Section 2.2.
- Storage: Store the multimeter in a cool, dry place away from direct sunlight and extreme temperatures. The recommended storage temperature and humidity are -10~40℃ (-4~140℉) and 45%-80%RH.
- Safety: To avoid electrical shock, always remove test leads before opening the case for battery replacement or any other maintenance.
5. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Device does not power on. | Low or dead battery; incorrect battery installation. | Check battery polarity; replace with a new AAA battery. |
| Inaccurate or no readings. | Poor contact with test leads; exceeding measurement range; damaged test leads. | Ensure firm contact; verify the measurement is within the device's specified range (e.g., do not measure voltage above 400V AC/DC); inspect and replace test leads if damaged. |
| "OL" or "-OL" displayed. | Measurement exceeds the meter's maximum range. | This indicates an over-range condition. Ensure the measured value is within the device's limits. |
| NCV/Live Wire detection not working or inconsistent. | Weak signal; interference; incorrect mode. | Ensure the sensor is close to the source; minimize interference from other electrical devices; ensure correct mode is selected (long press blue button for Live Wire in Wall). |
6. Specifications
| Feature | Specification |
|---|---|
| Brand Name | BSIDE |
| Model Number | ADMS1 / ADMS1CL |
| Display Type | Digital Display, 2000 Counts |
| Screen Type | ADMS1: LCD Display; ADMS1CL: EBTN Display |
| Operating Mode | Auto Range |
| DC Voltage | 400V ±(0.8%+3) |
| AC Voltage | 400V ±(1.2%+5) |
| Measuring Resistance Range | 10MΩ ±(1.2%+3) |
| Frequency | 1000Hz ±(1.0%+5) (40Hz~1000Hz) |
| Continuity | Yes, beeper sounds if resistance < 30Ω |
| NCV Function | Yes (V~Alert, Sound and LED light alarm) |
| Live Wire in Wall Detection | Yes, <1.5cm depth detection, Voltage range: 90V~1000V AC / 6V~1000V AC |
| Flashlight | Yes |
| Indicator Light | Green (Low), Yellow (Mid), Red (High) for NCV |
| Power | AAA*1 (1.5V, not included) |
| Dimensions | 150*39*18mm |
| Weight | 65g (without battery) |
| Operating Temperature | 0 - 40 ℃ |
| Storage Temperature & Humidity | -10~40℃/-4~140℉, 45%-80%RH |
| Certification | CE, RoHS, FCC |
| Sampling Time | Approx. 0.4s |
| Temperature Coefficient | Less than 0.1x Accuracy/℃ |
| Polarity Indication | Self-indicating, '-' means Negative polarity |
| Work Height | 2000m |
| Over-range Display | 'OL' or '-OL' |

Figure 10: Dimensions of the BSIDE ADMS1 Multimeter.
7. Warranty and Support
For detailed warranty information, please refer to the terms provided by your seller at the time of purchase. For technical support or further assistance, please contact the BSIDE Tools Store directly.
A digital version of the user manual (PDF) is available for download: User Manual (PDF).
8. User Tips
- Choose the Right Display: If you frequently work outdoors in bright conditions, the ADMS1 model with its LCD display is recommended for better visibility. For indoor or low-light environments, the ADMS1CL with its EBTN screen offers superior clarity.
- Portability: The compact and lightweight design (0.065kg without battery) of the ADMS1/ADMS1CL makes it highly portable. It can easily fit into a pocket or tool bag, reducing bulk.
- Flashlight Utility: Don't forget to utilize the built-in flashlight (short press the blue button) when working in dimly lit areas or during power outages.
- Safety First: Always ensure test leads are properly inserted and avoid measuring voltages exceeding 400V AC/DC to prevent damage to the device and ensure personal safety.