PINTECH N1070A

Rate this product if you’ve used it
Contents

PINTECH N1070A N Differential Probe User Manual

Model: N1070A

1. Introduction

The PINTECH N1070A is a high-voltage differential probe designed for safe and accurate measurements with oscilloscopes. It enables the observation of differential signals in high-voltage environments, providing isolation and protection for the oscilloscope and the user. This probe supports measurements up to 7000Vp-p with a bandwidth of 50MHz, making it suitable for a wide range of electrical testing applications. Key features include an automatic zero button, integrated voltage overload protection, and broad compatibility with various oscilloscope models.

PINTECH N1070A Differential Probe with accessories

The PINTECH N1070A Differential Probe and its included accessories.

2. Safety Information

WARNING: This device is designed to measure high voltages. Improper use can result in serious injury or death. Always adhere to safety procedures for high-voltage environments.

  • Maximum Input Voltage: Do not exceed the maximum input differential voltage of 7000V (DC + Peak AC) at 1/1000 attenuation or 700V (DC + Peak AC) at 1/100 attenuation.
  • Measurement Category: The probe is rated for 1000V rms CAT III. Ensure your measurement environment and all connected equipment comply with this safety rating.
  • Grounding: Always ensure proper grounding of both the oscilloscope and the circuit under test before making any connections.
  • Overload Protection: The probe features voltage overload protection and an overload warning light. If the overload light illuminates, immediately disconnect the probe from the circuit.
  • Power Supply: Use only the specified 6V power adapter or appropriate batteries. Using an incorrect power source can damage the device and pose a safety risk.
  • Inspection: Before each use, inspect the probe, cables, and test leads for any signs of damage. Do not use if damaged.

3. Package Contents

Verify that all items are present and undamaged upon unpacking:

  • 1 x PINTECH N1070A Differential Probe Unit
  • 1 x 6V Power Adapter
  • 1 x Pair of Test Hooks (Red and Black)
  • Integrated BNC Output Cable
  • Integrated Red and Black Input Leads
Power adapter and test hooks included with the probe

The included 6V power adapter and a pair of test hooks.

4. Product Overview

Familiarize yourself with the components and controls of the N1070A differential probe:

Labeled diagram of PINTECH N1070A Differential Probe showing controls and ports

Diagram showing the components of the N1070A probe, including the BNC output, power switch, adapter interface, power indicator, overload warning, attenuation switch, and banana plug input terminals.

  • BNC Output Line: This cable connects directly to an input channel on your oscilloscope.
  • Power Switch: Used to turn the differential probe unit ON or OFF.
  • 6V Adapter Interface: Connect the provided 6V power adapter here to power the probe.
  • Power Indicator Light (Red): Illuminates when the probe is powered on.
  • Overload Warning Light (Red): Flashes or illuminates when the input voltage exceeds the safe operating limits for the selected attenuation ratio.
  • Attenuation Ratio Switch: Allows selection between 1/100 and 1/1000 attenuation ratios.
  • Banana Plug Input Terminals: These are the connection points for the red and black test leads.

5. Setup

Follow these steps to set up your differential probe for measurement:

  1. Powering the Probe: The N1070A can be powered by either the included 6V power adapter or internal batteries.
    • Using the Power Adapter: Connect the provided 6V power adapter to the adapter interface on the side of the probe.
    • Using Batteries: Open the battery compartment (located on the back of the probe, refer to image below) and insert the required batteries, ensuring correct polarity.
    Diagram showing battery and adapter power options for the probe

    The probe can be powered by internal batteries (left) or an external 6V adapter (right).

    View of the battery compartment on the back of the probe

    Location of the battery compartment for battery power option.

  2. Connecting to Oscilloscope: Connect the BNC output cable of the differential probe to an input channel on your oscilloscope. Ensure the oscilloscope's input impedance is set to 1MΩ.
  3. Connecting Test Leads: Attach the red and black test leads to the banana plug input terminals on the probe. Securely attach the test hooks to the ends of the test leads.
Example setup connecting the differential probe to an oscilloscope and a power source

An example setup showing the differential probe connected to an oscilloscope and a power source for measurement.

6. Operating Instructions

  1. Power On: Flip the power switch to the 'ON' position. The red power indicator light should illuminate.
  2. Select Attenuation Ratio: Choose the appropriate attenuation ratio (1/100 or 1/1000) using the switch on the probe, based on the expected input voltage.
    • Use 1/100 for lower differential voltages (up to 700V DC+Peak AC).
    • Use 1/1000 for higher differential voltages (up to 7000V DC+Peak AC).
    Hand operating the attenuation switch on the differential probe

    A hand adjusting the attenuation ratio switch on the probe.

  3. Automatic Zero Adjustment: Press the 'Auto Zero' button (if available, or implied by the probe's design) to calibrate the probe and remove any DC offset, ensuring accurate measurements.
  4. Connect to Circuit: Carefully connect the red and black test hooks to the two points in the circuit where you intend to measure the differential voltage. Ensure secure connections and always exercise extreme caution when working with live circuits.
  5. Observe Waveform: Monitor the waveform on your oscilloscope. If the overload warning light illuminates, immediately disconnect the probe from the circuit. Re-evaluate the expected voltage and select a higher attenuation ratio if necessary, or verify that the input voltage is within the probe's specified limits.
  6. Power Off: After completing your measurements, disconnect the probe from the circuit and turn off the power switch.

7. Maintenance

  • Cleaning: Clean the exterior of the probe with a soft, dry, lint-free cloth. Do not use abrasive cleaners, solvents, or harsh chemicals, as these may damage the casing or internal components.
  • Storage: Store the probe in a dry, dust-free environment, away from direct sunlight and extreme temperatures, when not in use.
  • Battery Replacement: If operating on battery power, replace batteries when the power indicator light dims or the probe's performance degrades. Ensure to use the correct battery type and observe proper polarity during installation.
  • Calibration: For optimal accuracy and performance, periodic calibration by qualified service personnel is recommended.
  • Service: For any repairs or advanced maintenance, the product must be returned to the maintenance department designated by the manufacturer. Customers are responsible for prepaying shipping charges, duties, and taxes for products returned for warranty service.
Text detailing maintenance and warranty service terms

Important information regarding product maintenance and service returns.

8. Troubleshooting

ProblemPossible CauseSolution
Probe does not power on.No power from adapter or dead batteries.Check adapter connection and power outlet. If using batteries, replace them with fresh ones.
Overload warning light illuminates.Input voltage exceeds selected attenuation range.Immediately disconnect the probe. Select the 1/1000 attenuation ratio. If the light still illuminates, the input voltage is too high for the probe.
Incorrect or noisy readings on oscilloscope.Improper connection, incorrect oscilloscope settings, probe malfunction.Ensure all connections (probe to oscilloscope, test leads to probe, test hooks to circuit) are secure. Verify the oscilloscope's input impedance is set to 1MΩ. Press the auto-zero button. If the problem persists, contact support.

9. Specifications

ParameterValue
ModelN1070A
Bandwidth50MHz
Error+/-1%
Input Impedance4M Ohm // 7pF each side ground
Output Voltage Swing (into 50 K ohm load)+/-7V
Output Voltage Offset (typical)<+/- 5mV
Output Impedance (typical)50 ohm (for using 1M ohm input system oscilloscope)
Supply PowerExternal power leads (6V adapter or batteries)
BNC Cable Length90cm
Test Lead Length30cm
Weight500g
Dimensions (L×W×H)69x26x165mm
Attenuation Ratio1:1000 / 1:100
CMRR (typical)-80dB@60Hz, -50dB@1MHz
Maximum Input Differential Voltage (DC+ Peak AC)7000V@1/1000, 700V@1/100
Measurement Category1000V rms CAT III

10. User Tips

No specific user tips were available from provided reviews or Q&A content. However, general best practices for using differential probes include:

  • Always ensure your oscilloscope's input impedance is set to 1MΩ for accurate measurements when using this probe.
  • Before connecting to a circuit, estimate the voltage range to select the appropriate attenuation ratio. Start with the highest attenuation (1/1000) if unsure.
  • Keep the test leads as short as possible to minimize noise pickup, especially in high-frequency measurements.

11. Warranty and Support

For any technical assistance, troubleshooting, or warranty claims, please contact the seller or manufacturer directly. Keep your purchase records handy for faster service.

Maintenance Service: This product must be returned to the maintenance department designated by the company for repair. Customers are responsible for prepaying shipping charges, duties, and taxes for products returned for warranty service.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.

Was this page helpful?