Hantek TO1000 Series

Contents

Hantek TO1000 Series Portable Digital Oscilloscope User Manual

Models: TO1254D, TO1154D, TO1204D, TO1112, TO1112C, TO1112D

1. Introduction

The Hantek TO1000 series represents a new generation of multi-function, full touch screen portable digital oscilloscopes. Designed for portability and durability, these devices integrate an oscilloscope, multimeter, signal generator, and spectrum analyzer into a single, compact unit. Featuring a thin body, light weight, and a unique hanging design, the TO1000 series is built to free your hands and withstand demanding environments with its anti-fall and shock-resistant construction.

Equipped with a large-capacity battery and fast-charging support, the TO1000 series ensures long-lasting operation and reliable performance for various testing and measurement applications.

Front view of the Hantek TO1254D portable digital oscilloscope, highlighting its compact design and touch screen interface.
Figure 1: Hantek TO1254D Portable Digital Oscilloscope
Video 1: Hantek TO1000 Series Overview, demonstrating key features and portability.

2. Key Features

  • Multi-touch Large Screen: 800x480 resolution with a user-friendly interface for intuitive operation.
  • Digital Storage Oscilloscope: Available in 2 or 4 channels, with bandwidths up to 250MHz, a sampling rate of 1GS/s, and 8M storage depth. Supports various triggers including edge, slope, pulse width, video, and timeout. Offers up to 42 measurement functions.
  • Arbitrary Function Signal Generator: Maximum output frequency of 25MHz, 12-bit high resolution, and 200MS/s sampling rate. Includes a variety of built-in arbitrary waveforms and supports AM/FM modulation. Output impedance can be switched between high and low.

    Hantek TO1254D oscilloscope displaying the signal source function interface with waveform parameters and type selection.
    Figure 2: Signal Source Function Interface
  • High-Precision Digital Multimeter: Measures AC/DC voltage, current, resistance, capacitance, diode, and continuity. Features data recording, storage, trend graphs, and statistical analysis capabilities.

    Hantek TO1254D oscilloscope displaying the digital multimeter function interface with voltage readings and measurement options.
    Figure 3: Digital Multimeter Function Interface
  • One-Key Waveform Storage: Convenient and quick saving of waveforms.
  • Durable Design: Unique hanging feet for multi-angle adjustment, anti-drop, and shock resistance.
  • Long-Lasting Battery: Built-in 10000mAh removable lithium battery provides abundant power and up to half a year of standby time.

    Rear view of the Hantek TO1254D, showing the compartment for four 18650 batteries, indicating 10000mAh strong endurance.
    Figure 4: Battery Compartment (Holds 4x 18650 Batteries)
  • Fast Charging: Standard 18W charger and Type-C interface compatible with mobile phone chargers for convenience.

    Side view of the Hantek TO1254D showing the USB ports and the Type-C charging port with a 9V2A fast charging cable connected.
    Figure 5: Type-C Fast Charging Port

3. Package Contents

Upon opening the instrument package, please verify that all items listed below are present and in good condition.

A black carrying case with 'Hantek' logo, labeled 'Instrument Package * 1'.
Figure 6: Instrument Package
  • Main Unit (Host) x 1

    The Hantek TO1254D main unit, a portable digital oscilloscope, labeled 'Host * 1'.
    Figure 7: Main Unit
  • Oscilloscope Probe(s)

    • One probe for 2-channel series models.
    • Two probes for 4-channel series models.
    An oscilloscope probe with a user's guide, labeled 'Oscilloscope Probe (One for two Channel Series and Two for four Channel Series)'.
    Figure 8: Oscilloscope Probe
  • Multimeter Probe x 1 (Standard for TO1000C/D Series only)

    Red and black multimeter probes, labeled 'Multimeter Probe * 1 (Only Standard Configuration of TO1000C/D Series)'.
    Figure 9: Multimeter Probe
  • Crocodile Clips

    • One set for 2-channel series models.
    • Two sets for 4-channel series models.
    • One additional set for models with signal source function.
    Two sets of crocodile clips, labeled 'Crocodile Clip (One for Two Channel Series and Two for four Channel Series One More for the Model With Signal Source Function)'.
    Figure 10: Crocodile Clips
  • 18W Adapter x 1

  • Type-C Charging Cable x 1

    An 18W adapter and a Type-C charging cable, labeled '18W Adapter * 1, Type-C Charging Cable * 1'.
    Figure 11: Power Adapter and Cable

4. Setup

  1. Unpacking: Carefully remove the oscilloscope and all accessories from the instrument package.
  2. Initial Charge: Before first use, fully charge the device using the provided 18W adapter and Type-C charging cable. The device supports fast charging.
  3. Battery Installation (if applicable): The device uses 18650 lithium batteries. Ensure they are correctly installed in the battery compartment if not pre-installed.
  4. Power On/Off: Press and hold the power button to turn the device on or off.
  5. Adjusting the Kickstand: Utilize the unique hanging foot design (kickstand) on the back of the device to position it at a comfortable viewing angle on a flat surface or hang it for hands-free operation.
Side view of Hantek TO1254D with its kickstand extended, showing the device standing on a surface.
Figure 12: Device with Kickstand Extended

5. Operating Instructions

The Hantek TO1000 series features a multi-touch screen for intuitive navigation and control. The main interface provides quick access to different functions: Oscilloscope (OSC), Digital Multimeter (DMM), Arbitrary Function Generator (AFG), History/Record (H/R), and Print.

Hantek TO1254D main screen showing icons for Home, OSC, DMM, AFG, H/R, and Print on the left, and main function icons like OSC, DMM, AFG, File Browser, Settings, and Pictures in the center.
Figure 13: Main User Interface

5.1. Oscilloscope (OSC) Mode

  1. From the main screen, tap the 'OSC' icon to enter oscilloscope mode.
  2. Connect the oscilloscope probe(s) to the BNC input channels (CH1, CH2, CH3, CH4) on the top of the device.
  3. Connect the probe to the circuit under test.
  4. Use touch gestures (pinch-to-zoom, drag) to adjust horizontal (time base) and vertical (voltage scale) settings.
  5. Select trigger type (Edge, Slope, Pulse Width, Video, Timeout) and adjust trigger level as needed.
  6. Utilize the 42 measurement functions for automatic waveform analysis.
  7. Tap the 'Save' icon for one-key waveform storage.
Hantek TO1254D oscilloscope displaying multiple waveforms (yellow, blue, red) on screen, with various control options at the bottom.
Figure 14: Oscilloscope Mode Displaying Multiple Waveforms
A hand interacting with the touch screen of the Hantek TO1254D, demonstrating pinch-to-zoom gesture on a sine wave.
Figure 15: Touch Screen Interaction for Waveform Adjustment

5.2. Digital Multimeter (DMM) Mode

  1. From the main screen, tap the 'DMM' icon to enter multimeter mode.
  2. Connect the multimeter probes to the dedicated input ports (V/Ω/C/+, COM, mA, A) on the side of the device.
  3. Select the desired measurement function (voltage, current, resistance, capacitance, diode, continuity) from the on-screen menu.
  4. The device will display the measurement results.
  5. Use the data recording function to monitor and record data changes over time. Trend graphs can be generated and exported.
Side view of Hantek TO1254D showing the multimeter input ports: V/Ω/C/+, COM, mA, A.
Figure 16: Multimeter Input Ports

5.3. Arbitrary Function Generator (AFG) Mode

  1. From the main screen, tap the 'AFG' icon to enter arbitrary function generator mode.
  2. Connect the output of the AFG (AFG port) to the desired circuit using crocodile clips or appropriate cables.
  3. Select the desired waveform (sine, square, ramp, pulse, arbitrary) and adjust parameters such as frequency, amplitude, and offset using the touch screen controls.
  4. The device supports AM/FM modulation.
Hantek TO1254D oscilloscope displaying the signal source function interface with waveform parameters and type selection.
Figure 17: Arbitrary Function Generator Interface

6. User Tips

  • Channel Verification: When purchasing, confirm the number of channels (e.g., 4 channels) to ensure it meets your specific application requirements.
  • Probe Calibration: Regularly calibrate your oscilloscope probes for accurate measurements. Refer to the detailed instructions in the full user manual for the calibration procedure.
  • Battery Management: To maximize battery life, fully charge the device before extended use and avoid completely draining the battery frequently. The removable battery design allows for easy replacement if needed.
  • Touch Screen Responsiveness: For optimal touch screen responsiveness, ensure the screen is clean and free from debris. Use light, precise touches.

7. Maintenance

  • Cleaning: Use a soft, dry cloth to clean the device's exterior. For the screen, use a microfiber cloth and a screen-safe cleaning solution. Avoid abrasive cleaners or solvents.
  • Storage: Store the device in a cool, dry place away from direct sunlight and extreme temperatures. If storing for an extended period, ensure the battery is partially charged (around 50%) to prevent degradation.
  • Battery Care: If the battery is removable, inspect it periodically for any signs of damage or swelling. Replace damaged batteries immediately.
  • Software Updates: Check the Hantek official website periodically for firmware updates to ensure optimal performance and access to new features.

8. Troubleshooting

  • Device Not Powering On: Ensure the battery is charged. Connect the device to the charger and attempt to power on. If using removable batteries, check if they are correctly inserted.
  • No Waveform Display: Verify that the oscilloscope probes are securely connected to both the device and the circuit under test. Check the channel settings (e.g., vertical scale, position) and trigger settings. Ensure the input signal is within the device's measurement range.
  • Multimeter Readings Incorrect: Check that the multimeter probes are correctly connected to the appropriate input jacks for the selected measurement type. Ensure the function selection matches the measurement being performed.
  • Touch Screen Unresponsive: Restart the device. If the issue persists, ensure the screen is clean.
  • Fast Charging Not Working: Verify that you are using the provided 18W adapter and Type-C cable, or a compatible fast charger. Check for any damage to the cable or charging port.

9. Specifications

9.1. General Specifications

  • Display Size: 5.0 - 6.9 Inches
  • Display Resolution: 640*480 Pixels
  • Battery Included: Yes
  • IS Battery Demountable: Yes
  • DIY Supplies: Electrical
  • Certification: CE
  • Origin: Mainland China

9.2. Oscilloscope Specifications

ParameterTO1000 Series (1G Sampling)TO1112 Series (250M Sampling)
Horizontal Scale Range2ns/div~100s/div (1, 2, 5 sequence)2ns/div~100s/div (1, 2, 5 sequence)
Incremental Time Measurement Accuracy± (1 sampling interval +100ppm × reading +0.6ns)± (1 sampling interval +100ppm × reading +0.6ns)
Average (Full Bandwidth)>16 times on average>16 times on average
Incremental Time Measurement Accuracy (Full Bandwidth)± (1 sampling interval +100ppm × reading +0.4ns)± (1 sampling interval +100ppm × reading +0.4ns)
Sampling Intervalseconds/grid ÷200seconds/grid ÷200
A/D Converter8-bit resolution, each channel sampled simultaneously8-bit resolution, each channel sampled simultaneously
Vertical Scale Range2mV/div~10V/div at input BNC10mV/div~10V/div at input BNC
Vertical Resolution8bit8bit
Vertical Sensitivity Range2mV/div~10V/div10mV/div~10V/div
Offset Range (2mV/div~100mV/div)±1V±1Vmax
Offset Range (200mV/div~1V/div)±10V±10Vmax
Offset Range (2V/div~10V/div)±50V±50Vmax
Dynamic Range±5div (8bit)±5div (8bit)
Optional Analog Bandwidth Limitation20MHz, each channel independently selectable20MHz, each channel independently selectable
DC Gain Accuracy±3% FullScale±3% FullScale
Isolation Between Channels40dB, DC to the maximum rated bandwidth of each model40dB, DC to the maximum rated bandwidth of each model
Note: Bandwidth reduced to 6MHz when using a 1X probe.
Sampling Rate Range1GSa/S250MSa/s
Acquisition ModesNormal, Average, Peak, High resolutionNormal, Average, Peak, High resolution
Waveform Interpolation(sinx)/x(sinx)/x
Detailed table of oscilloscope specifications including horizontal scale, time measurement accuracy, vertical resolution, and acquisition modes.
Figure 18: Detailed Oscilloscope Specifications

9.3. Model Comparison

ModelOscilloscope ChannelBandwidthSampling RateStorage DepthSignal Source (AFG)Multimeter
TO1154D4 CH150 MHz1GSa/S8M25MHzYes
TO1204D4 CH200 MHz1GSa/S8M25MHzYes
TO1254D4 CH250 MHz1GSa/S8M25MHzYes
TO11122 CH110 MHz250MSa/S8M--
TO1112C2 CH110 MHz250MSa/S8M-Yes
TO1112D2 CH110 MHz250MSa/S8M25MHzYes
Table comparing different Hantek TO1000 series models based on oscilloscope channels, bandwidth, sampling rate, storage depth, signal source, and multimeter functions.
Figure 19: Hantek TO1000 Series Model Comparison

10. Warranty and Support

Hantek products are designed for reliability and performance. For detailed warranty information, please refer to the official Hantek website or contact your local distributor. Technical support and service are available through authorized service centers.

For further assistance, please visit the Hantek support page or consult the comprehensive user manual provided with your device.