1. Introduction
The Hantek TO1000 series represents a new generation of multi-function, full touch screen portable digital oscilloscopes. Designed for portability and durability, these devices integrate an oscilloscope, multimeter, signal generator, and spectrum analyzer into a single, compact unit. Featuring a thin body, light weight, and a unique hanging design, the TO1000 series is built to free your hands and withstand demanding environments with its anti-fall and shock-resistant construction.
Equipped with a large-capacity battery and fast-charging support, the TO1000 series ensures long-lasting operation and reliable performance for various testing and measurement applications.

2. Key Features
- Multi-touch Large Screen: 800x480 resolution with a user-friendly interface for intuitive operation.
- Digital Storage Oscilloscope: Available in 2 or 4 channels, with bandwidths up to 250MHz, a sampling rate of 1GS/s, and 8M storage depth. Supports various triggers including edge, slope, pulse width, video, and timeout. Offers up to 42 measurement functions.
Arbitrary Function Signal Generator: Maximum output frequency of 25MHz, 12-bit high resolution, and 200MS/s sampling rate. Includes a variety of built-in arbitrary waveforms and supports AM/FM modulation. Output impedance can be switched between high and low.

Figure 2: Signal Source Function Interface High-Precision Digital Multimeter: Measures AC/DC voltage, current, resistance, capacitance, diode, and continuity. Features data recording, storage, trend graphs, and statistical analysis capabilities.

Figure 3: Digital Multimeter Function Interface - One-Key Waveform Storage: Convenient and quick saving of waveforms.
- Durable Design: Unique hanging feet for multi-angle adjustment, anti-drop, and shock resistance.
Long-Lasting Battery: Built-in 10000mAh removable lithium battery provides abundant power and up to half a year of standby time.

Figure 4: Battery Compartment (Holds 4x 18650 Batteries) Fast Charging: Standard 18W charger and Type-C interface compatible with mobile phone chargers for convenience.

Figure 5: Type-C Fast Charging Port
3. Package Contents
Upon opening the instrument package, please verify that all items listed below are present and in good condition.

Main Unit (Host) x 1

Figure 7: Main Unit Oscilloscope Probe(s)
- One probe for 2-channel series models.
- Two probes for 4-channel series models.

Figure 8: Oscilloscope Probe Multimeter Probe x 1 (Standard for TO1000C/D Series only)

Figure 9: Multimeter Probe Crocodile Clips
- One set for 2-channel series models.
- Two sets for 4-channel series models.
- One additional set for models with signal source function.

Figure 10: Crocodile Clips 18W Adapter x 1
Type-C Charging Cable x 1

Figure 11: Power Adapter and Cable
4. Setup
- Unpacking: Carefully remove the oscilloscope and all accessories from the instrument package.
- Initial Charge: Before first use, fully charge the device using the provided 18W adapter and Type-C charging cable. The device supports fast charging.
- Battery Installation (if applicable): The device uses 18650 lithium batteries. Ensure they are correctly installed in the battery compartment if not pre-installed.
- Power On/Off: Press and hold the power button to turn the device on or off.
- Adjusting the Kickstand: Utilize the unique hanging foot design (kickstand) on the back of the device to position it at a comfortable viewing angle on a flat surface or hang it for hands-free operation.

5. Operating Instructions
The Hantek TO1000 series features a multi-touch screen for intuitive navigation and control. The main interface provides quick access to different functions: Oscilloscope (OSC), Digital Multimeter (DMM), Arbitrary Function Generator (AFG), History/Record (H/R), and Print.

5.1. Oscilloscope (OSC) Mode
- From the main screen, tap the 'OSC' icon to enter oscilloscope mode.
- Connect the oscilloscope probe(s) to the BNC input channels (CH1, CH2, CH3, CH4) on the top of the device.
- Connect the probe to the circuit under test.
- Use touch gestures (pinch-to-zoom, drag) to adjust horizontal (time base) and vertical (voltage scale) settings.
- Select trigger type (Edge, Slope, Pulse Width, Video, Timeout) and adjust trigger level as needed.
- Utilize the 42 measurement functions for automatic waveform analysis.
- Tap the 'Save' icon for one-key waveform storage.


5.2. Digital Multimeter (DMM) Mode
- From the main screen, tap the 'DMM' icon to enter multimeter mode.
- Connect the multimeter probes to the dedicated input ports (V/Ω/C/+, COM, mA, A) on the side of the device.
- Select the desired measurement function (voltage, current, resistance, capacitance, diode, continuity) from the on-screen menu.
- The device will display the measurement results.
- Use the data recording function to monitor and record data changes over time. Trend graphs can be generated and exported.

5.3. Arbitrary Function Generator (AFG) Mode
- From the main screen, tap the 'AFG' icon to enter arbitrary function generator mode.
- Connect the output of the AFG (AFG port) to the desired circuit using crocodile clips or appropriate cables.
- Select the desired waveform (sine, square, ramp, pulse, arbitrary) and adjust parameters such as frequency, amplitude, and offset using the touch screen controls.
- The device supports AM/FM modulation.

6. User Tips
- Channel Verification: When purchasing, confirm the number of channels (e.g., 4 channels) to ensure it meets your specific application requirements.
- Probe Calibration: Regularly calibrate your oscilloscope probes for accurate measurements. Refer to the detailed instructions in the full user manual for the calibration procedure.
- Battery Management: To maximize battery life, fully charge the device before extended use and avoid completely draining the battery frequently. The removable battery design allows for easy replacement if needed.
- Touch Screen Responsiveness: For optimal touch screen responsiveness, ensure the screen is clean and free from debris. Use light, precise touches.
7. Maintenance
- Cleaning: Use a soft, dry cloth to clean the device's exterior. For the screen, use a microfiber cloth and a screen-safe cleaning solution. Avoid abrasive cleaners or solvents.
- Storage: Store the device in a cool, dry place away from direct sunlight and extreme temperatures. If storing for an extended period, ensure the battery is partially charged (around 50%) to prevent degradation.
- Battery Care: If the battery is removable, inspect it periodically for any signs of damage or swelling. Replace damaged batteries immediately.
- Software Updates: Check the Hantek official website periodically for firmware updates to ensure optimal performance and access to new features.
8. Troubleshooting
- Device Not Powering On: Ensure the battery is charged. Connect the device to the charger and attempt to power on. If using removable batteries, check if they are correctly inserted.
- No Waveform Display: Verify that the oscilloscope probes are securely connected to both the device and the circuit under test. Check the channel settings (e.g., vertical scale, position) and trigger settings. Ensure the input signal is within the device's measurement range.
- Multimeter Readings Incorrect: Check that the multimeter probes are correctly connected to the appropriate input jacks for the selected measurement type. Ensure the function selection matches the measurement being performed.
- Touch Screen Unresponsive: Restart the device. If the issue persists, ensure the screen is clean.
- Fast Charging Not Working: Verify that you are using the provided 18W adapter and Type-C cable, or a compatible fast charger. Check for any damage to the cable or charging port.
9. Specifications
9.1. General Specifications
- Display Size: 5.0 - 6.9 Inches
- Display Resolution: 640*480 Pixels
- Battery Included: Yes
- IS Battery Demountable: Yes
- DIY Supplies: Electrical
- Certification: CE
- Origin: Mainland China
9.2. Oscilloscope Specifications
| Parameter | TO1000 Series (1G Sampling) | TO1112 Series (250M Sampling) |
|---|---|---|
| Horizontal Scale Range | 2ns/div~100s/div (1, 2, 5 sequence) | 2ns/div~100s/div (1, 2, 5 sequence) |
| Incremental Time Measurement Accuracy | ± (1 sampling interval +100ppm × reading +0.6ns) | ± (1 sampling interval +100ppm × reading +0.6ns) |
| Average (Full Bandwidth) | >16 times on average | >16 times on average |
| Incremental Time Measurement Accuracy (Full Bandwidth) | ± (1 sampling interval +100ppm × reading +0.4ns) | ± (1 sampling interval +100ppm × reading +0.4ns) |
| Sampling Interval | seconds/grid ÷200 | seconds/grid ÷200 |
| A/D Converter | 8-bit resolution, each channel sampled simultaneously | 8-bit resolution, each channel sampled simultaneously |
| Vertical Scale Range | 2mV/div~10V/div at input BNC | 10mV/div~10V/div at input BNC |
| Vertical Resolution | 8bit | 8bit |
| Vertical Sensitivity Range | 2mV/div~10V/div | 10mV/div~10V/div |
| Offset Range (2mV/div~100mV/div) | ±1V | ±1Vmax |
| Offset Range (200mV/div~1V/div) | ±10V | ±10Vmax |
| Offset Range (2V/div~10V/div) | ±50V | ±50Vmax |
| Dynamic Range | ±5div (8bit) | ±5div (8bit) |
| Optional Analog Bandwidth Limitation | 20MHz, each channel independently selectable | 20MHz, each channel independently selectable |
| DC Gain Accuracy | ±3% FullScale | ±3% FullScale |
| Isolation Between Channels | 40dB, DC to the maximum rated bandwidth of each model | 40dB, DC to the maximum rated bandwidth of each model |
| Note: Bandwidth reduced to 6MHz when using a 1X probe. | ||
| Sampling Rate Range | 1GSa/S | 250MSa/s |
| Acquisition Modes | Normal, Average, Peak, High resolution | Normal, Average, Peak, High resolution |
| Waveform Interpolation | (sinx)/x | (sinx)/x |

9.3. Model Comparison
| Model | Oscilloscope Channel | Bandwidth | Sampling Rate | Storage Depth | Signal Source (AFG) | Multimeter |
|---|---|---|---|---|---|---|
| TO1154D | 4 CH | 150 MHz | 1GSa/S | 8M | 25MHz | Yes |
| TO1204D | 4 CH | 200 MHz | 1GSa/S | 8M | 25MHz | Yes |
| TO1254D | 4 CH | 250 MHz | 1GSa/S | 8M | 25MHz | Yes |
| TO1112 | 2 CH | 110 MHz | 250MSa/S | 8M | - | - |
| TO1112C | 2 CH | 110 MHz | 250MSa/S | 8M | - | Yes |
| TO1112D | 2 CH | 110 MHz | 250MSa/S | 8M | 25MHz | Yes |

10. Warranty and Support
Hantek products are designed for reliability and performance. For detailed warranty information, please refer to the official Hantek website or contact your local distributor. Technical support and service are available through authorized service centers.
For further assistance, please visit the Hantek support page or consult the comprehensive user manual provided with your device.