1. Introduction
This manual provides essential information for the safe and effective use of the SUSWE 750W VFD (Variable Frequency Drive) Frequency Converter. This device is designed to control the speed of 3-phase AC motors from a single-phase 220V AC input, offering precise motor fan speed regulation, constant pressure water supply control, and energy-saving capabilities. It features a vector overload type control and a user-friendly interface for various industrial and domestic applications.
Video: Demonstration of the SUSWE VFD controlling a motor and adjusting frequency.
2. Specifications
| Feature | Specification |
|---|---|
| Model Number | suswe-750 |
| Type | DC/AC Inverter |
| Input Voltage | Single Phase 200V-240V AC |
| Output Voltage | 3 Phase 200V-240V AC |
| Input Frequency | 50/60Hz |
| Output Frequency Range | 0-99Hz |
| Output Power | 750W (0.2kW ~ 0.75kW) |
| Weight | 0.5 kg |
| Dimensions (L*W*H) | 130mm * 60.5mm * 102.5mm |
| Opening Size for Installation | 130mm * 52.5mm * 80mm |
| Output Type | SINGLE |
| Origin | Mainland China |
| Certification | CE, FCC, RoHS |

Figure 2.1: Product Dimensions
3. Product Overview
The SUSWE VFD features a compact design with an intuitive control panel and clearly labeled terminals.
3.1 Control Panel

Figure 3.1: Control Panel Layout and Key Functions
- Display Area: Shows frequency, current, and other operational parameters.
- MODE Key: Used to view set frequency (Fxxx), operating frequency (Hxxx), operating current (Axxx), motor direction (FWD/REV), input voltage (Uxxx), inverter temperature (Txxx), input point status (Lxxx), and PID parameter display (X.X-X.X).
- Up Key (▲): Adds function when setting data or increases frequency when controlled by the panel.
- Down Key (▼): Subtracts data function when setting data or reduces frequency when controlled by the panel.
- ENTER Key: Enters parameter mode when setting Pxxx parameters and saves the set parameters after modification.
- JOG Key: Initiates jog operation function.
- RUN Key: Starts inverter panel operation.
- STOP / RESET Key: Stops operation mode and clears fault alarm function in fault display mode.
- Potentiometers: Used for regulating frequency.
3.2 External Terminals

Figure 3.2: External Terminals
The VFD is equipped with various terminals for power input, motor output, and control signals. Refer to the wiring diagram in Section 4 for detailed connections.
4. Installation and Wiring
Proper installation and wiring are crucial for the safe and correct operation of the VFD. Ensure all power is disconnected before proceeding with installation or wiring.
4.1 Mounting
The VFD is designed for panel mounting. The recommended opening size for installation is 52.5mm (width) x 80mm (height) x 130mm (depth).

Figure 4.1: Installation Opening Size
4.2 Wiring Diagram
Connect the VFD according to the following diagram. Pay close attention to input power, motor connections, and control signals.

Figure 4.2: Detailed Wiring Diagram
4.2.1 Power and Motor Connections
- L, N: Single-phase 220V AC input.
- PE: Ground connection. Ensure proper grounding for safety.
- U, V, W: Three-phase output to the AC motor.
4.2.2 Control Terminals
- CM, NC, ON: Relay output terminals.
- YO: Multi-function composite output point. Can be configured as a brake resistor or general transistor output.
- X0, X1, X2, X3: External sensor inputs.
- 12V, GND, 5V, AI, A+: Analog input terminals. Supports 0-5V or 0-10V analog input. For 4-20mA input, an external 250Ω resistor is required.
- B-, A-: RS485 communication terminals.

Figure 4.3: Wiring Label Indication
5. Operation
The VFD features a user-friendly operation interface. Follow these steps for basic operation:
5.1 Power On and Initial Setup
- Ensure all wiring is correct and secure.
- Apply single-phase 220V AC power to the L and N terminals.
- The display will light up, showing the current status or default frequency.
5.2 Frequency Adjustment
- Using the Potentiometer: Rotate the potentiometer knob on the control panel to adjust the output frequency (and thus motor speed) from 0 to 99Hz.
- Using Up/Down Keys: In certain modes, the Up (▲) and Down (▼) keys can be used to fine-tune the frequency.
5.3 Starting and Stopping the Motor
- Start: Press the green RUN key to start the motor.
- Stop: Press the red STOP / RESET key to stop the motor. This key also clears any active fault alarms.
5.4 Parameter Setting
The VFD allows for advanced configuration through its parameter settings. Refer to the detailed key description for navigation.

Figure 5.1: Key Description for Parameter Setting
- Press the ENTER key to enter parameter mode. The display will show 'Pxxx'.
- Use the Up (▲) and Down (▼) keys to adjust the parameter number.
- Press ENTER again to modify the selected parameter's value.
- Use the Up (▲) and Down (▼) keys to change the value.
- Press ENTER to save the new value.
- If the panel does not display 'Pxxx', press the MODE key until 'Pxxx' is displayed.
5.5 Advanced Features
- V/F Curve Function: The VFD supports customizable V/F curve settings to meet specific application requirements.
- Real-time Parameter View: Use the Shift key to cycle through and view real-time operational parameters.
- Built-in Intelligent Logic Controller: Enables simple logic control functions for automated tasks.
6. Troubleshooting
This section provides a guide to common fault codes and their remedies. If a fault persists, contact technical support.

Figure 6.1: Fault Code Table
| Alarm Type | Fault Description | Fault Comment |
|---|---|---|
| OC | Instantaneous overcurrent | Check whether the motor is normal. |
| OCA | Acceleration overcurrent | Adjust the acceleration time appropriately. |
| OCD | Deceleration overcurrent | Adjust the deceleration time appropriately. |
| OCN | Constant speed overcurrent | Adjust the deceleration time appropriately. |
| OU | Overpressure | Check whether the machine is normal and the voltage is stable. |
| LU | Undervoltage | Adjust the acceleration and deceleration time properly, and check whether the mains supply is normal. |
| OH | Inverter overheating | Detect whether the mains supply is normal (180V-240V). |
| EF | External fault | Detect external sensors. Whether the input is normal. |
| ERS | Failure restart failed | Check whether the input is normal. |
| LP | Input phase failure | Restart the drive. |
| OL1 | Motor overload | Check whether the mains supply is normal. |
| OL2 | Inverter overload | Check whether the motor is normal and whether the load is too heavy. |
| OL3 | Temporary motor overload | Check whether the motor is normal and whether it matches the frequency converter power. |
| OL4 | Temporary overload of frequency converter | Check whether the load matches the motor. |
| 485 | Communication failure | Check whether the communication line is normal, and whether the upper computer communication is normal. |
| PID | PID failure | Check whether analog input is output and whether sensor is normal. |
| NO | No fault alarm | Check whether analog input is output and whether sensor is normal. |
7. User Tips
- The VFD is designed with a user-friendly interface, making parameter setting straightforward. Take advantage of the potentiometer for quick and easy speed adjustments.
- For optimal performance and safety, ensure that the motor's power rating is compatible with the VFD's output power (0.2kW to 0.75kW).
- Always double-check wiring connections before powering on the unit to prevent damage or malfunction.