1. Introduction
The HLK-LD6002C is a radar induction module developed by Hi-Link, based on the ADT6101P chip. It integrates a 57-64GHz RF transceiver system, 2T2R PCB microstrip antenna, 1MB flash memory, a radar signal processing unit, and an ARM® Cortex®-M3 kernel. This module utilizes the FMCW signal processing mechanism and advanced radar signal processing algorithms to accurately detect human presence and fall incidents. It is specifically designed for ceiling installation in small, single-person areas such as bathrooms and toilets, making it ideal for smart security and healthcare applications.
This module operates by detecting frequency modulated continuous wave signals and offers a large detection angle, supporting horizontal and elevation detection up to ±60°.
Figure 1: HLK-LD6002C Human Falling Detection Sensor Module
2. Key Features
- Radar detection based on FMCW frequency modulated continuous wave signal.
- Large detection angle, supporting horizontal ±60° and elevation ±60° detection.
- Implements personnel fall detection function.
- Universal UART interface, providing communication protocol.
- Supports UART parameter adjustment to meet different scenario requirements.
- Compact in size, only 25*23mm, supports pin insertion.
- Not affected by temperature, humidity, noise, airflow, dust, light, and other environmental factors.
3. Application Scenarios
The HLK-LD6002C module is suitable for a variety of applications:
- Health Care and Care: Ideal for monitoring in bathrooms and toilets to detect falls.
- Home Security: Enhances safety in residential environments.
- Smart Home Scenario Application: Integrates into smart home systems for automated safety features.
Figure 2: Diverse applications of Hi-Link modules, including the HLK-LD6002C.
4. Setup and Hardware Description
4.1 Overall Dimensions
The module has compact dimensions, making it suitable for integration into various systems.
Figure 3: HLK-LD6002C Module Dimensions (25.00mm x 23.00mm)
4.2 Pin Definition
The module features an 8-pin interface. Refer to the table below for pin definitions and their functions.
Figure 4: HLK-LD6002C Module Pinout
| Pin Order Number | Pin Name | Description | Remarks |
|---|---|---|---|
| 1 | 3V3 | POWER INPUT 3.3V | |
| 2 | GND | GND | |
| 3 | P19 | GPIO19 | Boot1 |
| 4 | TX2 | GPIO20 | |
| 5 | AIO1 | Analog IO | |
| 6 | SCL0 | GPIO07 | |
| 7 | TX0 | Connected to external serial port TX | |
| 8 | RX0 | Connected to external serial port RX |
4.3 Module Peripheral Reference Design
The following diagram illustrates a typical peripheral reference design for the HLK-LD6002C module, showing connections for power and communication with a host MCU.
Figure 5: Typical Application Circuit / Peripheral Reference Design
Important: The module power supply is 3.3V, and the input power supply capacity must be greater than 1A. The output voltage of the module IO port is 3.3V. The default serial port rate is 115200 with no parity.
4.4 Boot Configuration
The boot configuration determines how the module starts.
| BOOT1 | BOOT0 | Remarks | |
|---|---|---|---|
| Configuration level | 0 | 1 | Flash starts within the module |
| Pin foot position number | Pin8 | Pin12 |
Note: BOOT1 and BOOT0 module internals are pulled up. BOOT1 must be connected to a low level before the module starts.
4.5 Installation Method and Sensing Range
The module is designed for top-mounted installation. The recommended hanging height is between 2.2 to 3.0 meters, providing a maximum induction radius of 2 meters.
Figure 6: Schematic Diagram of Top Installation
The installation direction annotation indicates the orientation of the module for optimal detection.
Figure 7: Installation Direction Annotation
5. Operating Instructions
5.1 GUI Visualization Tool Application
The HLK-LD6002C module can be configured and monitored using a Graphical User Interface (GUI) visualization tool. Follow these steps to use the tool:
- Device Connection:
- Select the connected serial port.
- Set the Baud rate to 115200.
- Click the [Connect] button. The module will then start to detect.
- Data Examining:
- Select the 3D view window.
- Drag and zoom the view in the image to the appropriate size with the mouse.
- View the System Log window below.
- Check the message information. If no falls are detected, no abnormalities should be reported.
Figure 8: GUI Data Examination Interface
When a fall is detected, the 3D view will display "Someone fell" and the System Log window will show the message "Someone fell!".
- Parameter Configuration:
- Select the [Fall] button in the Option window to enter the parameter configuration interface.
- Mounting Height: Set according to the actual installation height.
- Fall Threshold: This threshold is based on the distance from the point cloud to the ground for fall detection. It can be modified and debugged based on usage scenarios.
- Fall Sensitivity: Sensitivity setting. Not recommended for modification.
- DetectRectXL: Left boundary of detection area.
- DetectRectXR: Right boundary of detection area.
- DetectRectZF: Front boundary of detection area.
- DetectRectZB: Back boundary of detection area.
- After filling in the required parameters, click the (Apply) button to complete the configuration. Confirm that the parameters in the [Fall] window (bottom left corner) match the set parameters.
- To read parameters set within the module, use [Get All FallParas].
- To obtain the current software version number, click the [Get] button in the Version window.
Figure 9: GUI Parameter Configuration Interface
6. Maintenance and Precautions
- Electromagnetic Wave Transmission: Ensure no metal or other media block the electromagnetic wave transmission in front of the antenna during operation.
- Shell Material and Distance: Different shell materials and distances from the inner surface of the shell can affect the returned spectrum energy and parameter settings. Fine-tuning may be required. It is generally recommended that the module be 5-6mm away from the housing.
- Testing and Adjustment: Test the module with default settings first. If performance is not as expected, the shell structure can be sent to the manufacturer for testing and reference setting adjustments.
- Recommended Shell Material: Plastic is recommended for the shell due to the radar's sensitivity. Materials with high attenuation may affect detection.
- Installation Environment: Avoid installing near air conditioning outlets, fans, or other objects that cause airflow or vibration.
- Multiple Modules: When installing multiple modules, ensure a spacing greater than 0.5 meters between them, and avoid having antennas of different modules facing each other.
- Sensitivity Adjustment: Sensitivity can be adjusted based on user scenarios. Contact technical support for assistance with sensitivity adjustments.
6.1 Radome Design Considerations
A radome protects the radar antenna from environmental factors like rain and wind. However, it can impact radar performance by causing dielectric loss, reflection loss, and distortion of the antenna beam. Proper radome design is crucial to minimize these effects and improve radar performance.
- Material Selection: Choose radome materials with smaller dielectric constant and loss angle (dissipation factor) to reduce impact on radar performance, while ensuring firmness and low cost.
- Surface and Thickness: The radome should have a smooth surface and uniform thickness.
- Antenna Thickness Requirements: The thickness (T) of the radome should ideally follow the formula:
T = N * (c / (2f * sqrt(εr))), where N is an integer (1, 2, 3...), c is the speed of light (3x10^8 m/s), f is the center frequency (60GHz), and εr is the material permittivity (dielectric constant). For f=60GHz, c/(2f) = 2.5mm.
| Material | Dielectric Constant (εr) | Dissipation Factor (tan δ) |
|---|---|---|
| Merlon | 2.9 | 0.012 |
| ABS | 2.0-3.5 | 0.0050-0.019 |
| PEEK | 3.2 | 0.0048 |
| PTFE (Teflon®) | 2 | <0.0002 |
| Plexiglass® | 2.6 | 0.009 |
| Glass | 5.75 | 0.003 |
| Pottery and porcelain | 9.8 | 0.0005 |
| PE | 2.3 | 0.0003 |
| PBT | 2.9-4.0 | 0.002 |
7. Troubleshooting
- Inconsistent Detection Distance: The effective detection distance can vary due to target Radar Cross Section (RCS) and environmental factors. This is considered normal. Ensure the installation environment is free from obstructions and interference.
- Module Not Powering On/Unstable Operation: Verify the power supply meets the requirements: input voltage 3.1-3.5V, power ripple ≤ 50mV, and current ≥ 1A. If using a DCDC power supply, the switching frequency should be no less than 2MHz.
- False Detections or Missed Detections: Review the