1. Introduction
This SWR & Watt meter is highly accurate for measuring Forward Power, Reflected Power, and the VSWR of Analog and Digital Transceivers. It is designed for use with HF (1.6-60MHz) and V.UHF (125-525MHz) bands, supporting up to 200 Watts.
2. Main Features
- Large LCD (3.5”) display for easy reading of measurements.
- Single push button for switching between Forward/Reflected Power and VSWR ratio display.
- Selectable measurement modes for DMR (TDMA), AM, and SSB (available on MAX models).
- LCD backlight display for visibility in various lighting conditions.
- Convenient control layout for straightforward operation.
3. Package Contents
Upon unpacking, please verify that all items listed below are present and in good condition:
- 1 × NISSEI DG-503MAX Digital SWR/Watt Meter
- 1 × Operation Manual (this document)
- 1 × 12V DC power wire

4. Specifications
| Feature | Specification |
|---|---|
| Model | DG-503 MAX |
| Frequency Range | HF: 1.6-60MHz & V.UHF 125-525MHz |
| Measurement (Analog Mode) | CW, FM, FDMA |
| Measurement (MAX Mode) | DMR (TDMA), AM, SSB |
| Calibration Point | 28/145/435MHz |
| Power Range | 0-200W |
| Accuracy | +/-5% |
| Minimum Power for SWR | 1W |
| Input/Output Connector | SO239 |
| Weight (Net) | 750g |
| Insertion Loss | Less than 0.1dB |
| Testing Function | Fwd/Ref power & VSWR Ratio |
| Input/Output Impedance | 50 ohm |
| Dimension (W/H/D) | 140*84*122 mm |
| Accessories | Operation Manual, 12V DC Wire |

5. Product Overview

Front Panel:
- LCD Display: Indicates Forward Power (FWD), Reflected Power (REF), and Voltage Standing Wave Ratio (VSWR).
- HF & V/UHF Band Switch: Toggles between High Frequency (HF) and Very High Frequency/Ultra High Frequency (V/UHF) bands.
- Power Switch: Turns the device ON/OFF.
- MAX Button: Used for measuring DMR (TDMA), AM, and SSB modes. This function is specific to the DG-503MAX model and is active when the rear MAX switch is engaged.
Rear Panel:
- TX Coax Connector (5 & 8): Connects to the transmitter's RF output.
- ANT Coax Connector (6 & 9): Connects to the antenna system.
- 12V DC Power Source (7): Input for the 12V DC power wire. Ensure correct polarity: black wire is negative (-), black/white wire is positive (+).
- MAX Switch (10): A physical switch to enable or disable the DMR (TDMA), AM, SSB measurement modes. Push to the right (towards the 'black dot') to activate for DG-503MAX only.
6. Setup
Follow these steps to set up your NISSEI DG-503MAX:
- Connect Power: Plug the provided 12V DC power wire into the 12V DC input jack on the rear panel of the meter. Ensure the power source is stable and provides 12V DC.
- Connect Transmitter: Connect your transmitter's RF output to the TX coax connector on the rear panel.
- Connect Antenna: Connect your antenna system to the ANT coax connector on the rear panel.
- Power On: Flip the Power switch on the front panel to the ON position. The LCD display should illuminate.
7. Operation
Once the meter is set up and powered on, you can begin taking measurements:
- Select Frequency Band: Use the HF/V.UHF band switch on the front panel to select the appropriate frequency range for your operation (HF for 1.6-60MHz or V.UHF for 125-525MHz).
- Select Measurement Mode (MAX models only): If measuring DMR (TDMA), AM, or SSB, ensure the MAX switch on the rear panel is pushed to the right (towards the black dot). Then, use the MAX button on the front panel to cycle through these modes. For analog modes (CW, FM, FDMA), ensure the rear MAX switch is disengaged.
- Transmit: Initiate transmission from your radio. The meter will automatically display the Forward Power (FWD), Reflected Power (REF), and VSWR.
- Read Measurements: Observe the values on the large LCD display.

8. User Tips
- Frequency Range Check: Always verify that your operating frequency falls within the meter's specified range (HF: 1.6-60MHz; V.UHF: 125-525MHz). For example, frequencies like 76-120MHz or commercial FM (88-108MHz) are outside the measurable range of this device.
- Stable Power Supply: Ensure a stable 12V DC power supply for accurate readings. Fluctuations can affect measurement precision.
- Secure Connections: Always ensure all coax connectors (TX and ANT) are securely fastened to prevent signal loss and inaccurate readings.
9. Troubleshooting
If you encounter issues with your DG-503MAX, try the following:
- No Display/Power: Check the 12V DC power connection and ensure the power switch is ON. Verify the power source is functioning correctly.
- Inaccurate Readings: Ensure all cable connections are secure. Check that the correct frequency band (HF/V.UHF) is selected. Confirm that your operating frequency is within the meter's specified range.
- No Readings: Verify that your radio is transmitting power. Check the integrity of your coaxial cables and antenna system.
- Mode Selection Issues (MAX models): Ensure the physical MAX switch on the rear panel is correctly set for the desired measurement type (Analog or Digital).
10. Maintenance
To ensure the longevity and optimal performance of your NISSEI DG-503MAX, follow these maintenance guidelines:
- Cleaning: Use a soft, dry cloth to clean the exterior of the meter. Avoid using abrasive cleaners or solvents that could damage the finish or display.
- Storage: Store the meter in a cool, dry place away from direct sunlight, extreme temperatures, and high humidity.
- Handling: Handle the device with care to avoid physical damage. Do not drop or expose it to excessive vibration.
- Cable Inspection: Periodically inspect all connecting cables for signs of wear or damage. Replace any damaged cables immediately.
11. Warranty and Support
For any technical assistance, warranty claims, or further inquiries regarding your NISSEI DG-503MAX, please refer to the contact information provided by your original point of purchase or the manufacturer's official support channels. Keep your purchase receipt as proof of purchase for warranty purposes.