1. Product Overview
The PowMr MPPT Solar Charge Controller is designed to efficiently manage power from your solar panels to your battery bank, ensuring optimal charging and system protection. It is compatible with 12V and 24V systems and supports various battery types including LiFePO4, Lithium, Flooded, and Sealed batteries.
Available in 25A, 35A, and 45A maximum charging currents, these controllers feature high tracking efficiency (up to 98%) and peak conversion efficiency (up to 97%).


2. Safety Information
The controller is equipped with 9 built-in electronic protections to ensure safe and reliable operation of your solar system. Always follow proper wiring procedures and safety guidelines when installing and operating the device.

Built-in Protections:
- PV over current protection
- PV short circuit protection
- PV reverse polarity protection
- Battery reverse polarity protection
- Battery over voltage protection
- Battery over discharge protection
- Lithium battery low temperature protection
- Load overcurrent protection
- Overtemperature protection
3. Setup and Installation
The user-friendly design ensures easy and quick installation. The controller is equipped with a built-in temperature sensor and a lithium battery activation function.
Wiring Instructions:
- Connect the battery to the controller.
- Connect the PV Array (solar panels) to the controller.
- Connect the DC Load to the controller.
Important: Connect the system in the order of 1) battery, 2) load, 3) PV array. Disconnect the system in the reverse order: 3) PV array, 2) load, 1) battery.

Battery Type Setting:
The controller is compatible with various 12V/24V battery types. To set the battery type:
- Long press the BAT/▲ key to enter the setting program.
- Use the BAT/▲ and DC/▼ keys to toggle through the battery type options.
- Press the SET/⚙ key to save and confirm your selection.
If you select 'User-defined' battery type, you can proceed with setting specific battery parameters.

4. Operating the Controller
The controller features a backlight LCD screen that displays important system information, working modes, and error codes.
Working Modes:
- 3.0: Night mode, no charging.
- 4.0: MPPT Charging Mode.
- 7.0: Boost Charging Mode.
- 8.0: Floating Charge mode.
Load Work Modes:
The controller supports multiple load work modes for managing your DC load:
- 00H: Load Turn Off.
- 24H: Load always Turn ON.
- 01H~23H: Time control (Set load ON's duration).

5. Maintenance
To ensure the longevity and optimal performance of your solar charge controller, regular maintenance is recommended:
- Keep the controller clean and free from dust and debris.
- Periodically check all wiring connections for tightness and corrosion.
- Ensure adequate ventilation around the controller to prevent overheating.
- Inspect the solar panels and battery terminals for any signs of damage or wear.
6. Troubleshooting
The LCD screen displays error codes to help diagnose issues. Refer to the table below for common fault codes and their solutions.

Common Fault Codes and Solutions:
| Fault Code | Fault Cause | Solution |
|---|---|---|
| 18 | Input photovoltaic voltage too low | Increase the number of solar panels or connect them in series to raise the photovoltaic input voltage. |
| 60 | Overtemperature protection | Allow the equipment to cool to below the recovery temperature to resume normal charging and discharging. |
| 63 | Battery voltage too high | Measure to confirm if battery voltage exceeds rated voltage and disconnect photovoltaic array circuit breaker. |
| 65 | Battery voltage too low | Charge the battery until voltage exceeds the undervoltage recovery point. Refer to '3.7 Default Parameters for Different Battery Types' for specific details. |
| 71 | Input photovoltaic voltage too high | Reduce the number of photovoltaic arrays connected to the controller to lower photovoltaic input; or adjust series and parallel connections to reduce voltage or current values. |
| 73 | Overcharging current | Reduce output terminal load to ensure total load is within rated limits of the controller and battery. |
| 72 | Overdischarging current | Reduce output terminal load to ensure total load is within rated limits of the controller and battery. |
7. Specifications
The PowMr MPPT Solar Charge Controllers are available in three models with varying current capacities:
| Model | POW-M25-PRO | POW-M35-PRO | POW-M45-PRO |
|---|---|---|---|
| Max Charging Current | 25A | 35A | 45A |
| System Voltage | 12V / 24V Auto | ||
| Max PV Open-Circuit Voltage | 60V | 80V | 100V |
| Max Power (12V) | 300W | 420W | 540W |
| Max Power (24V) | 600W | 840W | 1080W |
| Dimensions | 6.3" x 4.53" x 2.01" | 7.68" x 5.31" x 2.56" | 7.68" x 5.31" x 2.56" |
| Net Weight | 1.1lb | 1.98lb | 2.28lb |
General Specifications:
- Application: Charger Controller, Water Heater Controller, Voltage Controller, Lighting Controller, Solar System Controller
- Is Smart Device: Yes
- Certification: CE, FCC, RoHS
8. Warranty and Support
The PowMr MPPT Solar Charge Controller comes with a 12-month warranty from the date of purchase. This warranty covers defects in materials and workmanship under normal use.
For technical support, troubleshooting assistance, or warranty claims, please contact PowMr customer service through your retailer or the official PowMr website.
9. User Tips
- Check Connections Regularly: Ensure all wiring connections are secure and free from corrosion to maintain optimal performance and prevent potential issues.
- Verify Dimensions: Before installation, always double-check the physical dimensions of your specific controller model against your planned mounting location to ensure a proper fit. Refer to the 'Specifications' section for detailed measurements.
- Monitor LCD Screen: Pay attention to the LCD screen for any displayed fault codes. Addressing these promptly can prevent further system complications.