BSIDE HX1

Contents

BSIDE HX1 Thermal Imaging Camera User Manual

High Precision Infrared Thermal Imager for Professional and Home Use

1. Introduction

The BSIDE HX1 is a high-precision infrared thermal imaging camera designed for a wide range of applications, including PCB repair, pipeline detection, floor heating inspection, electrical testing, and machinery maintenance. Featuring a 240x240 pixel thermal imager resolution and a temperature measurement range of -20°C to 550°C, it provides clear and accurate thermal images. Its robust design, multiple color modes, and data storage capabilities make it an essential tool for professionals and DIY enthusiasts alike.

2. Package Contents

Upon opening the package, please ensure all the following items are present:

  • HX1 Thermal Imaging Camera
  • USB Cable (Type-C)
  • Quality Certificate
  • Instruction Manual
  • Storage Box/Case
  • Lanyard
BSIDE HX1 Thermal Imaging Camera and accessories including USB cable, manual, and case.
Figure 2.1: Package Contents

3. Device Overview

Familiarize yourself with the components and controls of your BSIDE HX1 thermal imager.

Diagram of BSIDE HX1 showing charging indicator, USB Type-C interface, display screen, up/down buttons, power/menu/confirm button, back button, laser, thermal imaging sensor, photo/trigger button, and fixing screw hole of bracket.
Figure 3.1: Structure Panel of the HX1

Display Description

The 2.4-inch TFT LCD screen provides a clear view of thermal images and measurement data. Key indicators on the display include:

Detailed display description of the BSIDE HX1 thermal imager, labeling various elements like current auto-tracking temperature, center point, distances, maximum/minimum temperature, palette, emissivity, brand, model, time, battery level, and USB connection symbol.
Figure 3.2: Display Elements
  1. Current auto-tracking temperature measurement level
  2. Measure the temperature center point
  3. Current auto-tracking temperature
  4. Measure distances
  5. Maximum temperature
  6. Palette
  7. Minimum temperature
  8. Temperature unit symbol
  9. Emissivity
  10. Brand
  11. Model
  12. Time
  13. Battery level
  14. USB connection symbol

4. Charging and Battery

The HX1 is equipped with a built-in 3.7V/2500mAh rechargeable lithium battery. To charge the device, connect it to a 5V/2A power source using the provided Type-C USB cable. The charging indicator on the device will show the charging status.

  • Charging Time: Less than 3 hours at 25°C.
  • Working Hours: More than 7 hours at 25°C.
BSIDE HX1 thermal imager connected to a laptop via USB-C for charging, showing a charging icon on its screen.
Figure 4.1: Charging the Device

5. Initial Setup and Settings

Before using your thermal imager, it is recommended to configure the basic settings to suit your preferences and measurement environment.

Navigating the Menu

Use the 'Power/Menu/Confirm' button (red button) to enter the menu and confirm selections. Use the 'Up' and 'Down' arrow keys to navigate through options, and the 'Back' button (yellow left arrow) to return to the previous screen or exit the menu.

Key Settings

  • Language: Select your preferred language (Chinese, English, German, Italian, French, Spanish, Japanese). For Russian language updates, refer to the provided download link in the Warranty/Support section.
  • Unit: Choose your desired temperature unit (°C, °F, Kelvin).
  • Time and Date: Set the current time and date for accurate record-keeping.
  • Laser: Enable or disable the laser pointer.
  • Auto Shutdown: Configure the automatic shutdown timer (optional 10, 20, 30, 40, 50, 60 minutes, or Disable). Default is disabled.
  • Emissivity: Adjust the emissivity value (0.01 to 1.00) based on the material being measured. Refer to the "Common Emissivity" table below for typical values.
  • Distance: Set the measurement distance for optimal accuracy.
  • Colorize (Color Palettes): Select from 15 different pseudo-color modes to visualize temperature differences.
  • Display Settings: Customize what information is shown on the screen, such as highest temperature point, lowest temperature point, center temperature point, parameters, and watermark.
  • Alarm: Configure temperature alarms.
  • Gear Position (Temperature Range): Select the appropriate temperature range for your measurement (-20°C to 150°C or 100°C to 550°C), or use Auto Switch.

6. Operation

Power On/Off

Press and hold the 'Power/Menu/Confirm' button (red button) to turn the device on or off. The boot speed is approximately 3 seconds.

Taking Temperature Measurements

Point the thermal imager at the target object. The screen will display the thermal image with real-time temperature readings. The device automatically tracks the highest, lowest, and center point temperatures. Use the laser pointer for precise targeting.

A hand holding the BSIDE HX1 thermal imager, using its laser pointer to target a component in an engine bay, displaying thermal data on screen.
Figure 6.1: Laser Pointing for Quick Positioning
A hand holding the BSIDE HX1 thermal imager, pointing it at electrical components in a server rack, showing thermal readings on the screen.
Figure 6.2: Thermal Imaging in an Electrical Cabinet

Color Palettes (Swatches)

The HX1 offers 15 pseudo-color modes to help visualize temperature distributions. You can switch between these modes in the 'Colorize' setting within the menu. Each mode highlights temperature differences in a unique way, making it easier to identify anomalies.

  • White Hot, Black Hot, Fusion 1, Rainbow, Fusion 2, Iron Red 1, Iron Red 2, Bark Brown, Color 1, Color 2, Ice Fire, Rain, Green Hot, Red Hot, Deep Blue.
Grid displaying 15 different false color modes (palettes) for thermal imaging, including White Hot, Black Hot, Fusion 1, Fusion 2, Iron Red 1, Iron Red 2, Rainbow, Red Hot, Deep Blue, Color 1, Color 2, Green Hot, Rain, Dark Brown, and Ice and Fire.
Figure 6.3: Multiple False Color Modes

Emissivity Adjustment

Emissivity is a crucial factor for accurate temperature measurement. Different materials emit infrared radiation differently. Adjust the emissivity setting (ε) in the menu to match the material you are inspecting. The default value is 0.95. Incorrect emissivity settings can lead to inaccurate readings.

Table 6.1: Common Emissivity Values
MaterialEmissivityMaterialEmissivity
Wood0.85Black paper0.86
Water0.96Polycarbonate0.80
Bricks0.75Concrete0.97
Stainless steel0.14Copper oxide0.78
Tape0.96Cast iron0.81
Aluminium Sheet0.09Rust0.80
Coin0.06Plaster0.75
Black aluminum0.95Paint0.90
Human Skin0.98Rubber0.95
Asphalt0.96Soil0.93
PVC Plastic0.93

Temperature Alarm

The device features an over-temperature red screen alarm. When a measured temperature exceeds or falls below a configurable threshold, the screen will trigger an alarm, visually indicating potential danger or anomalies. You can set these limits in the 'Alarm' menu.

BSIDE HX1 thermal imager showing an over-temperature red screen alarm with a visual representation of temperature limits from -20°C to 550°C and a configurable alert threshold.
Figure 6.4: Over-Temperature Red Screen Alarm

Data Storage and Export

The HX1 has a built-in memory card (4GB) capable of storing up to 30,000 images in BMP format. These stored pictures can be analyzed on a computer. Connect the device to your computer using the USB Type-C cable to access and export the images.

BSIDE HX1 thermal imager connected to a MacBook Pro, displaying a gallery of thermal images on the laptop screen, indicating data storage and export capabilities.
Figure 6.5: Data Storage and Export

7. Application Scenarios

The BSIDE HX1 is a versatile tool suitable for various professional and home inspection tasks, providing accurate temperature measurement regardless of environmental impact.

  • Overhaul of Underfloor Heating Pipes: Floor heating laying, acceptance, troubleshooting, and other links where engineers need accurate positioning and judgment.
  • Building Water Leak Detection: Property management and intuitively reflects HVAC and piping issues, such as running, dripping, and leaking problems.
  • Electronic and Electrical Testing: Inspection of key power equipment and maintenance of electronic circuits and components to determine possible points of failure.
  • Machinery and Equipment Testing: Process control, electronic integration, and electronic charging are used for operation and maintenance to prevent gaps, find and avoid O&M costs.
Four images demonstrating various temperature measurement application scenarios: underfloor heating pipes, building water leak detection, electronic and electrical testing, and machinery and equipment testing.
Figure 7.1: Temperature Measurement Application Scenarios

8. Maintenance

  • Cleaning: Use a soft, dry cloth to clean the device. Do not use abrasive cleaners or solvents. Ensure the lens is kept clean and free from dust or smudges for optimal performance.
  • Storage: Store the device in a cool, dry place away from direct sunlight and extreme temperatures. The recommended storage temperature is -40°C to 70°C.
  • Battery Care: To prolong battery life, avoid fully discharging the battery frequently. Charge the device regularly, even if not in use for extended periods.
  • Durability: The device features a sturdy anti-drop design with IP54 protection grade and can withstand drops from 1.5 meters.
Image showing the BSIDE HX1 thermal imager being dropped, highlighting its sturdy anti-drop design and IP54 protection grade, with a fall resistance of 1.5 meters.
Figure 8.1: Sturdy Anti-Drop Design

9. Troubleshooting

If you encounter issues with your BSIDE HX1, please refer to the following common problems and solutions:

  • Device not turning on: Ensure the battery is charged. Connect the device to a power source using the USB-C cable and allow it to charge for at least 30 minutes before attempting to power on again.
  • Inaccurate temperature readings:
    • Check the emissivity setting and adjust it according to the material being measured (refer to Table 6.1).
    • Ensure the lens is clean and free from obstructions.
    • Verify that the measurement distance is appropriate for the target.
  • Screen frozen or unresponsive: Try restarting the device by holding down the power button. If the issue persists, perform a factory reset (refer to the 'More Settings' menu for 'Restore factory settings').
  • Cannot transfer images to computer: Ensure the USB cable is securely connected to both the device and the computer. Check if the device is recognized by your computer's operating system.

For further assistance, please contact customer support.

10. Specifications

Detailed performance indicators for the BSIDE HX1 Thermal Imaging Camera:

Table 10.1: Performance Indicators
FeatureSpecification
Sensor typeVanadium oxide (VOx) microcalorimeter
Response Band8~14µm
Thermal image resolution240x240 Pixels
Noise equivalent temperature difference (NETD)≤60 mK (@25°C, F#1.0)
Angle of view (FOV)50.0°(H)×50°(V)/72.1°(D)
Spatial resolution (IFOV)8.89 mrad
Frame rate25Hz
Focal length of the imaging lens1.35 mm
Temperature measuring focal length0.3m~3m Adjustable
Temperature range-20℃~550℃
Accuracy of temperature measurement±2℃ or ±2% of the reading (take the larger value)
Unit of temperature measurementCelsius, Fahrenheit, Kelvin
Temperature resolution0.1℃
Emissivity0.01~1.00 Adjustable
Temperature measurement showsCenter point temperature measurement, high and low temperature tracking
Swatches (Color Palettes)White Hot, Black Hot, Fusion 1, Rainbow, Fusion 2, Iron Red 1, Iron Red 2, Bark Brown, Color 1, Color 2, Ice Fire, Rain, Green Hot, Red Hot, Deep Blue
Display screen2.4 inches TFT LCD
Display resolution320×240
Key functionsPower Key, up key, Down Key, Return key, Trigger key
Laser PointerYes
Temperature AlarmScreen font color alarm
Image storageBuilt-in memory card (4GB)
Number of image files30000
Image formatBMP
Shock/vibrationGB/T 2423.5-2019; GB/T2423.10-2008
Electromagnetic compatibility (EMC)GB/T17799.2, GB17799.3-2012
Protection levelIP54
Installation modeTripod mount UNC-20
Focus modeAuto focusing
Hardware interfaceType-C USB
Battery typeRechargeable lithium battery (3.7V/2500mAh)
The working hours of the battery>7h@25℃
Charging time<3h@25°℃
Charging voltage/current5V/2A
Boot speed~8 seconds
Automatic shutdownDisable (default); optional 10, 20, 30, 40, 50, 60 minutes, or Disable
Operating temperature-10°C~50°C
Storage temperature-40°C~70°C
Working humidity≤85%RH (Non-condensing)
Drop resistance1.5m
Product dimensions193.4*59.4*77.4mm
Product weight277g
Detailed table of performance indicators for the BSIDE HX1 thermal imager, covering sensor type, resolution, temperature range, accuracy, display, image storage, and environmental ratings.
Figure 10.1: Performance Indicators Summary
Table showing additional performance indicators for the BSIDE HX1 thermal imager, including charging time, voltage/current, boot speed, automatic shutdown options, operating and storage temperatures, humidity, drop resistance, product dimensions, and weight.
Figure 10.2: Additional Performance Indicators

11. Warranty and Support

The BSIDE HX1 Thermal Imaging Camera is certified with CE, FCC, and RoHS, ensuring compliance with international safety and environmental standards.

For technical support, warranty claims, or any inquiries regarding the product, please contact your retailer or the manufacturer directly. Keep your purchase receipt as proof of purchase.

Language Pack Update: For early version HX1 buyers or those needing to update the Russian language, a language pack upgrade system is available. You can download the language pack from the following link: https://www.mediafire.com/file/vrcwjz3t738qelc/HX1-Update.rar/file


Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.