1. Introduction
The BSIDE HX1 is a high-precision infrared thermal imaging camera designed for a wide range of applications, including PCB repair, pipeline detection, floor heating inspection, electrical testing, and machinery maintenance. Featuring a 240x240 pixel thermal imager resolution and a temperature measurement range of -20°C to 550°C, it provides clear and accurate thermal images. Its robust design, multiple color modes, and data storage capabilities make it an essential tool for professionals and DIY enthusiasts alike.
2. Package Contents
Upon opening the package, please ensure all the following items are present:
- HX1 Thermal Imaging Camera
- USB Cable (Type-C)
- Quality Certificate
- Instruction Manual
- Storage Box/Case
- Lanyard

3. Device Overview
Familiarize yourself with the components and controls of your BSIDE HX1 thermal imager.

Display Description
The 2.4-inch TFT LCD screen provides a clear view of thermal images and measurement data. Key indicators on the display include:

- Current auto-tracking temperature measurement level
- Measure the temperature center point
- Current auto-tracking temperature
- Measure distances
- Maximum temperature
- Palette
- Minimum temperature
- Temperature unit symbol
- Emissivity
- Brand
- Model
- Time
- Battery level
- USB connection symbol
4. Charging and Battery
The HX1 is equipped with a built-in 3.7V/2500mAh rechargeable lithium battery. To charge the device, connect it to a 5V/2A power source using the provided Type-C USB cable. The charging indicator on the device will show the charging status.
- Charging Time: Less than 3 hours at 25°C.
- Working Hours: More than 7 hours at 25°C.

5. Initial Setup and Settings
Before using your thermal imager, it is recommended to configure the basic settings to suit your preferences and measurement environment.
Navigating the Menu
Use the 'Power/Menu/Confirm' button (red button) to enter the menu and confirm selections. Use the 'Up' and 'Down' arrow keys to navigate through options, and the 'Back' button (yellow left arrow) to return to the previous screen or exit the menu.
Key Settings
- Language: Select your preferred language (Chinese, English, German, Italian, French, Spanish, Japanese). For Russian language updates, refer to the provided download link in the Warranty/Support section.
- Unit: Choose your desired temperature unit (°C, °F, Kelvin).
- Time and Date: Set the current time and date for accurate record-keeping.
- Laser: Enable or disable the laser pointer.
- Auto Shutdown: Configure the automatic shutdown timer (optional 10, 20, 30, 40, 50, 60 minutes, or Disable). Default is disabled.
- Emissivity: Adjust the emissivity value (0.01 to 1.00) based on the material being measured. Refer to the "Common Emissivity" table below for typical values.
- Distance: Set the measurement distance for optimal accuracy.
- Colorize (Color Palettes): Select from 15 different pseudo-color modes to visualize temperature differences.
- Display Settings: Customize what information is shown on the screen, such as highest temperature point, lowest temperature point, center temperature point, parameters, and watermark.
- Alarm: Configure temperature alarms.
- Gear Position (Temperature Range): Select the appropriate temperature range for your measurement (-20°C to 150°C or 100°C to 550°C), or use Auto Switch.
6. Operation
Power On/Off
Press and hold the 'Power/Menu/Confirm' button (red button) to turn the device on or off. The boot speed is approximately 3 seconds.
Taking Temperature Measurements
Point the thermal imager at the target object. The screen will display the thermal image with real-time temperature readings. The device automatically tracks the highest, lowest, and center point temperatures. Use the laser pointer for precise targeting.


Color Palettes (Swatches)
The HX1 offers 15 pseudo-color modes to help visualize temperature distributions. You can switch between these modes in the 'Colorize' setting within the menu. Each mode highlights temperature differences in a unique way, making it easier to identify anomalies.
- White Hot, Black Hot, Fusion 1, Rainbow, Fusion 2, Iron Red 1, Iron Red 2, Bark Brown, Color 1, Color 2, Ice Fire, Rain, Green Hot, Red Hot, Deep Blue.

Emissivity Adjustment
Emissivity is a crucial factor for accurate temperature measurement. Different materials emit infrared radiation differently. Adjust the emissivity setting (ε) in the menu to match the material you are inspecting. The default value is 0.95. Incorrect emissivity settings can lead to inaccurate readings.
| Material | Emissivity | Material | Emissivity |
|---|---|---|---|
| Wood | 0.85 | Black paper | 0.86 |
| Water | 0.96 | Polycarbonate | 0.80 |
| Bricks | 0.75 | Concrete | 0.97 |
| Stainless steel | 0.14 | Copper oxide | 0.78 |
| Tape | 0.96 | Cast iron | 0.81 |
| Aluminium Sheet | 0.09 | Rust | 0.80 |
| Coin | 0.06 | Plaster | 0.75 |
| Black aluminum | 0.95 | Paint | 0.90 |
| Human Skin | 0.98 | Rubber | 0.95 |
| Asphalt | 0.96 | Soil | 0.93 |
| PVC Plastic | 0.93 |
Temperature Alarm
The device features an over-temperature red screen alarm. When a measured temperature exceeds or falls below a configurable threshold, the screen will trigger an alarm, visually indicating potential danger or anomalies. You can set these limits in the 'Alarm' menu.

Data Storage and Export
The HX1 has a built-in memory card (4GB) capable of storing up to 30,000 images in BMP format. These stored pictures can be analyzed on a computer. Connect the device to your computer using the USB Type-C cable to access and export the images.

7. Application Scenarios
The BSIDE HX1 is a versatile tool suitable for various professional and home inspection tasks, providing accurate temperature measurement regardless of environmental impact.
- Overhaul of Underfloor Heating Pipes: Floor heating laying, acceptance, troubleshooting, and other links where engineers need accurate positioning and judgment.
- Building Water Leak Detection: Property management and intuitively reflects HVAC and piping issues, such as running, dripping, and leaking problems.
- Electronic and Electrical Testing: Inspection of key power equipment and maintenance of electronic circuits and components to determine possible points of failure.
- Machinery and Equipment Testing: Process control, electronic integration, and electronic charging are used for operation and maintenance to prevent gaps, find and avoid O&M costs.

8. Maintenance
- Cleaning: Use a soft, dry cloth to clean the device. Do not use abrasive cleaners or solvents. Ensure the lens is kept clean and free from dust or smudges for optimal performance.
- Storage: Store the device in a cool, dry place away from direct sunlight and extreme temperatures. The recommended storage temperature is -40°C to 70°C.
- Battery Care: To prolong battery life, avoid fully discharging the battery frequently. Charge the device regularly, even if not in use for extended periods.
- Durability: The device features a sturdy anti-drop design with IP54 protection grade and can withstand drops from 1.5 meters.

9. Troubleshooting
If you encounter issues with your BSIDE HX1, please refer to the following common problems and solutions:
- Device not turning on: Ensure the battery is charged. Connect the device to a power source using the USB-C cable and allow it to charge for at least 30 minutes before attempting to power on again.
- Inaccurate temperature readings:
- Check the emissivity setting and adjust it according to the material being measured (refer to Table 6.1).
- Ensure the lens is clean and free from obstructions.
- Verify that the measurement distance is appropriate for the target.
- Screen frozen or unresponsive: Try restarting the device by holding down the power button. If the issue persists, perform a factory reset (refer to the 'More Settings' menu for 'Restore factory settings').
- Cannot transfer images to computer: Ensure the USB cable is securely connected to both the device and the computer. Check if the device is recognized by your computer's operating system.
For further assistance, please contact customer support.
10. Specifications
Detailed performance indicators for the BSIDE HX1 Thermal Imaging Camera:
| Feature | Specification |
|---|---|
| Sensor type | Vanadium oxide (VOx) microcalorimeter |
| Response Band | 8~14µm |
| Thermal image resolution | 240x240 Pixels |
| Noise equivalent temperature difference (NETD) | ≤60 mK (@25°C, F#1.0) |
| Angle of view (FOV) | 50.0°(H)×50°(V)/72.1°(D) |
| Spatial resolution (IFOV) | 8.89 mrad |
| Frame rate | 25Hz |
| Focal length of the imaging lens | 1.35 mm |
| Temperature measuring focal length | 0.3m~3m Adjustable |
| Temperature range | -20℃~550℃ |
| Accuracy of temperature measurement | ±2℃ or ±2% of the reading (take the larger value) |
| Unit of temperature measurement | Celsius, Fahrenheit, Kelvin |
| Temperature resolution | 0.1℃ |
| Emissivity | 0.01~1.00 Adjustable |
| Temperature measurement shows | Center point temperature measurement, high and low temperature tracking |
| Swatches (Color Palettes) | White Hot, Black Hot, Fusion 1, Rainbow, Fusion 2, Iron Red 1, Iron Red 2, Bark Brown, Color 1, Color 2, Ice Fire, Rain, Green Hot, Red Hot, Deep Blue |
| Display screen | 2.4 inches TFT LCD |
| Display resolution | 320×240 |
| Key functions | Power Key, up key, Down Key, Return key, Trigger key |
| Laser Pointer | Yes |
| Temperature Alarm | Screen font color alarm |
| Image storage | Built-in memory card (4GB) |
| Number of image files | 30000 |
| Image format | BMP |
| Shock/vibration | GB/T 2423.5-2019; GB/T2423.10-2008 |
| Electromagnetic compatibility (EMC) | GB/T17799.2, GB17799.3-2012 |
| Protection level | IP54 |
| Installation mode | Tripod mount UNC-20 |
| Focus mode | Auto focusing |
| Hardware interface | Type-C USB |
| Battery type | Rechargeable lithium battery (3.7V/2500mAh) |
| The working hours of the battery | >7h@25℃ |
| Charging time | <3h@25°℃ |
| Charging voltage/current | 5V/2A |
| Boot speed | ~8 seconds |
| Automatic shutdown | Disable (default); optional 10, 20, 30, 40, 50, 60 minutes, or Disable |
| Operating temperature | -10°C~50°C |
| Storage temperature | -40°C~70°C |
| Working humidity | ≤85%RH (Non-condensing) |
| Drop resistance | 1.5m |
| Product dimensions | 193.4*59.4*77.4mm |
| Product weight | 277g |


11. Warranty and Support
The BSIDE HX1 Thermal Imaging Camera is certified with CE, FCC, and RoHS, ensuring compliance with international safety and environmental standards.
For technical support, warranty claims, or any inquiries regarding the product, please contact your retailer or the manufacturer directly. Keep your purchase receipt as proof of purchase.
Language Pack Update: For early version HX1 buyers or those needing to update the Russian language, a language pack upgrade system is available. You can download the language pack from the following link: https://www.mediafire.com/file/vrcwjz3t738qelc/HX1-Update.rar/file