1. Introduction

This manual provides essential information for the safe and efficient operation of your Sumry SP Series Hybrid Solar Inverter. Please read this manual thoroughly before installation and use, and keep it for future reference.

Key Features:

  • Pure sine wave output for sensitive electronics.
  • Programmable supply priority for PV (Photovoltaic), battery, or grid.
  • High PV input voltage range (55~450VDC).
  • Built-in Max 110A (for 3.8KW & 6.2KW models) MPPT solar charger.
  • Compatible with various battery types, including lithium-ion.
  • Supports BMS communication with compatible lithium batteries.
  • Smart battery charge design to optimize battery life.
  • Comprehensive protection against overload, high temperature, and inverter output short circuit.
  • Cold start function.
  • Intelligent fan speed adjustment for efficient cooling.
  • Optional built-in anti-dusk kit for harsh environments.
  • Optional WiFi & GPRS modules for iOS and Android monitoring.

2. Safety Information

WARNING: This inverter generates high voltage. Installation and maintenance should only be performed by qualified personnel. Failure to follow these instructions may result in serious injury or death.

  • Ensure all wiring is correctly sized and properly insulated.
  • Always disconnect all power sources (PV, battery, utility) before performing any maintenance or wiring.
  • Do not operate the inverter if it is damaged or appears to be malfunctioning.
  • Ensure proper grounding of the inverter.
  • Keep children away from the inverter and its connections.
  • Install the inverter in a well-ventilated area, away from flammable materials.

3. Product Overview

3.1. Physical Components

Sumry SP Series Hybrid Solar Inverter front view

Figure 1: Front view of the Sumry SP Series Hybrid Solar Inverter, highlighting power ratings, charging current, MPPT range, and frequency.

Sumry SP Series Hybrid Solar Inverter LCD display and function keys

Figure 2: Inverter's LCD display, LED indicators, and function keys.

LED Indicators:

LED IndicatorMessages
AC / INV (Green)Solid On: Output is powered by utility in Line mode.
Flashing: Output is powered by battery or PV in battery mode.
CHG (Green)Solid On: Battery is fully charged.
Flashing: Battery is charging.
FAULT (Red)Solid On: Fault occurs in the inverter.
Flashing: Warning condition occurs in the inverter.

Function Keys:

Function KeyDescription
ESCTo exit setting mode
UPTo go to previous selection
DOWNTo go to next selection
ENTERTo confirm the selection in setting mode or enter setting mode

4. Installation

Before installing and using the inverter, it is recommended to install 4 circuit breakers in the following 4 positions:

  1. Between the battery pack and the inverter battery input.
  2. Between the solar panel and the photovoltaic input of the inverter.
  3. Between the power input of the grid and the inverter.
  4. Between inverter output and load.

The circuit breaker is to effectively prevent the misconnection or reverse connection of the mains input and the inverter output; when there is a short circuit, load short circuit, or overload in the output, the circuit breaker can directly cut off the circuit to protect the inverter.

4.1. Wiring Diagram

Inverter wiring diagram showing connections to solar, generator/utility, battery, and home appliances.

Figure 3: General wiring diagram for the hybrid solar inverter.

Detailed wiring and technical specifications diagram for the inverter.

Figure 4: Detailed wiring and technical specifications, including AC input/output, PV input, and battery connections. Ensure to first ground the PE protective conductor.

4.2. Solar Panel Wiring Method (Series/Parallel)

Solar panel series and parallel wiring diagrams.

Figure 5: Solar photovoltaic panel wiring methods.

  • In Series: Increases the voltage of the system. This voltage needs to be less than the hybrid inverter's maximum PV input voltage (Voc/inverter). Example: 41.92V * 6 = 251.52V.
  • In Parallel: Increases the current of the system. This current should not exceed the maximum PV input current of the hybrid inverter. Example: 10.35A * 2 = 20.7A.
  • The entire photovoltaic system should use the same type of photovoltaic panel.
  • PV cable dimensions: 6-8A/mm².

4.3. Circuit Breaker Specifications

Circuit breaker specification table for different inverter power ratings.

Figure 6: Recommended circuit breaker specifications.

  • For 3KW Inverter:
    • Battery to Inverter: 2P100A
    • PV Input to Inverter: 2P10A
    • Utility Input to Inverter: 2P32A
    • Inverter Output: 2P15A
  • For 3.8KW Inverter:
    • Battery to Inverter: 2P150A
    • PV Input to Inverter: 2P20A
    • Utility Input to Inverter: 2P40A
    • Inverter Output: 2P20A
  • For 6.2KW Inverter:
    • Battery to Inverter: 2P150A
    • PV Input to Inverter: 2P20A
    • Utility Input to Inverter: 2P63A
    • Inverter Output: 2P30A

4.4. Step-by-Step Installation Procedure

  1. Battery Connection: Install a circuit breaker between the battery and the inverter. After successful installation, open the breaker. Connect the appropriate battery (24V for 3kW/3.8kW, 48V for 6.2kW). Close the circuit breaker and measure the voltage on the battery side of the inverter to ensure it's normal.
  2. PV Input Connection: Install a circuit breaker between the PV input and the inverter. Turn on this circuit breaker after successful installation. Ensure the battery voltage is normal. Connect the solar energy. Close the circuit breaker between the PV input and the inverter. The inverter display will automatically light up and start charging.
  3. Inverter Startup: Press the button on the bottom right corner of the inverter to start the machine. Verify that there is 220V/230V/240V voltage output from the inverter output.
  4. AC Input/Output Connection: Install a circuit breaker between the AC input and the inverter. Install another circuit breaker between the output of the machine and the load. After successful installation, turn on the circuit breakers for both AC input and output. Connect the machine to the mains. Turn off the mains input circuit breaker, then turn off the circuit breaker of the inverter output after 2 minutes. This completes the installation procedure.

5. Operation

5.1. Working Modes

The Sumry SP Series inverter offers versatile working modes to optimize power usage:

  • Charging Modes (3 options):
    • Only Solar: Charges batteries exclusively from solar panels.
    • Solar First: Prioritizes solar charging, using utility/grid only when solar is insufficient.
    • Mains & Solar: Charges from both utility/grid and solar simultaneously.
  • Output Modes (2 options):
    • Solar First (SBU Priority): Prioritizes solar power for loads, then battery, then utility.
    • SBU First (Utility Priority): Prioritizes utility power for loads, then solar, then battery.
Diagram illustrating inverter operation with battery connected and when solar/AC power is unavailable.

Figure 7: Inverter operation diagrams showing power flow under different conditions. Note: This inverter must work with a battery. Ensure it is connected to a battery before connecting solar panels.

5.2. Monitoring and Control

The inverter features a comprehensive LCD display for user-configurable settings and monitoring. Optional WiFi and GPRS modules are available for remote monitoring and control via iOS and Android applications.

Video 1: Product overview and connection demonstration.

The inverter has a single communication port (COMM port) on the right side. You can choose to communicate via a WiFi module or a battery BMS (e.g., PACE or PYLONTECH protocols), but only one method can be active at a time. If you wish to use the WiFi module, it must be purchased separately.

6. Maintenance

  • Regularly inspect all wiring and connections for signs of wear, damage, or loose terminals.
  • Keep the inverter's ventilation openings clear of dust and debris to ensure proper heat dissipation. The intelligent fan speed adjustment helps maintain optimal operating temperature.
  • Periodically check battery terminals for corrosion and clean if necessary.
  • Ensure the inverter is installed in a clean, dry, and well-ventilated environment.
  • If the optional anti-dusk kit is installed, ensure it is clean and functioning correctly.
Image showing the inverter's strong heat dissipation features.

Figure 8: Inverter design for strong heat dissipation.

7. Troubleshooting

Refer to the LED indicators (Figure 2) for initial fault diagnosis. A solid red FAULT LED indicates a fault, while flashing indicates a warning condition.

Common Issues & Solutions:

  • No Power Output:
    • Check all circuit breakers (battery, PV, AC input, AC output) to ensure they are closed.
    • Verify battery voltage is within the normal operating range.
    • Ensure the inverter is turned on (press the power button).
    • Check for any fault codes on the LCD display.
  • Battery Not Charging:
    • Check PV input connections and ensure solar panels are receiving sufficient sunlight.
    • Verify PV input voltage is within the inverter's acceptable range (55-450VDC).
    • Ensure the CHG LED is flashing (charging) or solid (fully charged). If not, check PV circuit breaker.
    • If using utility charging, ensure AC input is connected and the utility circuit breaker is closed.
  • Discrepancy in Solar Input Current (User Tip):
    • The "Max Charging Current" (e.g., 80A/110A) refers to the maximum current the MPPT solar charger can deliver to the battery.
    • The "MAX.PV input current" (e.g., 10A/20A) refers to the maximum DC current that can be drawn from the solar panel array into the MPPT controller. These are different specifications. Always ensure your solar array's current output does not exceed the inverter's MAX.PV input current.
  • Overload/Over-temperature:
    • Reduce the connected load.
    • Ensure adequate ventilation around the inverter.
    • Check for blockages in the fan vents.

8. Specifications

The Sumry SP Series Hybrid Solar Inverter comes in various power ratings. Below are the general specifications:

Product data sheet for Sumry SP series inverters.

Figure 9: Product Data Sheet for SP Series models.

Technical parameters table for Sumry SP series inverters.

Figure 10: Technical parameters for SP Series models.

General Specifications:

  • Brand Name: SUMRY
  • Model Number: SP Series (3000W, 3800W, 6200W variants)
  • Output Type: SINGLE
  • Output Power: 1 - 200 KW (Specific models: 3000W, 3800W, 6200W)
  • Output Frequency: 50/60HZ
  • Output Current: 80/110A (Max Charging Current)
  • PV Input Voltage Range: 55-450VDC
  • AC Output Voltage: 220-240VAC
  • Battery Voltage: 24V (for 3kW/3.8kW models), 48V (for 6.2kW models)
  • Size: 550mm*400mm*190mm (approximate, may vary by model)
  • Weight: 10KG (approximate, may vary by model)
  • Certification: CE
  • Origin: Mainland China

Compatible Battery Types:

Diagram showing compatibility with various battery types: Flooded, Gel, Lithium-ion phosphate, Lithium-ion, AGM/Sealed, and User custom battery.

Figure 11: Inverter compatibility with multiple battery types.

  • Flooded (FLD)
  • Gel (GEL)
  • Lithium-iron phosphate (LI)
  • Lithium-ion (LI)
  • AGM/Sealed (SLD)
  • User custom Battery (USER)

9. User Tips

  • Solar Input Current Clarification: Be aware that "Max Charging Current" (e.g., 80A/110A) refers to the current delivered to the battery by the MPPT charger, while "MAX.PV input current" (e.g., 10A/20A) refers to the maximum DC current that can be drawn from the solar panel array into the MPPT controller. These are different specifications. Always ensure your solar array's current output does not exceed the inverter's MAX.PV input current.
  • Battery Requirement: This inverter requires a battery to operate. Ensure a compatible battery is connected and properly sized for your system before connecting solar panels or other power sources.
  • Communication Options: The inverter supports either WiFi module communication or battery BMS communication (PACE or PYLONTECH protocols) through a single COMM port. You cannot use both simultaneously.

10. Warranty and Support

For warranty information, technical support, or service inquiries, please contact your original point of purchase or the manufacturer directly. Keep your purchase receipt and product serial number handy for faster service.


Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.