BENYAR BY-5211

BENYAR BY-5211 Automatic Mechanical Watch Instruction Manual

Model: BY-5211 | Brand: BENYAR

Introduction

Thank you for choosing the BENYAR BY-5211 Automatic Mechanical Watch. This timepiece combines classic design with modern functionality, featuring an automatic mechanical movement, a luminous dial for visibility in low light, and robust water resistance. This manual provides essential information for the proper setup, operation, and maintenance of your watch to ensure its longevity and accurate performance.

BENYAR BY-5211 watch with green dial, close-up

Figure 1: BENYAR BY-5211 Automatic Mechanical Watch (Green Dial)

Specifications

Diagram of BENYAR BY-5211 watch dimensions and specifications

Figure 2: Watch Dimensions and Key Specifications

FeatureDetail
Model NumberBY-5211
MovementAutomatic Self-Wind (BY-9018) / Mechanical Hand Wind
Case MaterialAlloy
Case Thickness15mm / 0.59 inches
Dial Diameter42.5mm / 1.67 inches
Dial Window MaterialHardlex Mineral Glass
Band Material TypeStainless Steel
Band Width22mm / 0.86 inches
Band Length19cm / 7.48 inches (Max Perimeter)
Clasp TypeBracelet Clasp
Water Resistance Depth5 Bar (50 meters)
FeaturesLuminous, Complete Calendar (Date Display)
Weight142g / 0.31 lbs

Setup

  1. Initial Winding: As an automatic mechanical watch, it requires initial winding if it has stopped. Gently rotate the crown clockwise about 30-40 times while it is in the normal (pushed-in) position. This builds up the power reserve.
  2. Setting the Time: Pull the crown out to the furthest position (usually the second click). Rotate the crown to set the hour and minute hands to the correct time. Push the crown back in to start the watch.
  3. Setting the Date: Pull the crown out to the first click. Rotate the crown (usually counter-clockwise) to set the date. Avoid setting the date between 9 PM and 3 AM, as this is when the date change mechanism is engaged and could cause damage. If the current time falls within this window, set the time outside of it first, then adjust the date, and finally set the correct time. Push the crown back in when finished.

Video 1: Product showcase demonstrating various dial colors, luminous features, and the automatic movement.

Operating Your Watch

  • Automatic Movement: Your BENYAR BY-5211 watch is powered by an automatic mechanical movement. This means it winds itself through the natural motion of your wrist. When worn daily for at least 8-10 hours, it should maintain its power reserve.
  • Power Reserve: If the watch is not worn for an extended period, it will stop. Simply re-wind it manually (as described in "Initial Winding") or wear it for a few hours to restart the movement.
  • Luminous Dial: The dial features luminescent markers and hands, allowing for easy readability in low-light conditions. Exposure to light will charge the luminous material.
  • Water Resistance (50m/5 Bar): This watch is suitable for short periods of recreational swimming and showering. It is NOT suitable for diving, snorkeling, or high-impact water sports. Always ensure the crown is fully pushed in before any contact with water.
BENYAR BY-5211 watch with luminous dial glowing in the dark

Figure 3: Luminous dial in low light conditions

Maintenance

  • Cleaning: Wipe the watch regularly with a soft, dry cloth to remove dust and fingerprints. For the stainless steel bracelet, a slightly damp cloth can be used, followed by immediate drying.
  • Water Resistance Care: After exposure to saltwater, rinse the watch with fresh water and dry thoroughly. Avoid operating the crown or pushers while the watch is wet or submerged.
  • Avoid Extreme Conditions: Protect your watch from extreme temperatures, strong magnetic fields, and harsh chemicals (e.g., solvents, detergents).
  • Servicing: Mechanical watches benefit from periodic servicing (typically every 3-5 years) by a qualified watchmaker to ensure optimal performance and longevity.
Back of the BENYAR BY-5211 watch showing the automatic movement

Figure 4: View of the automatic mechanical movement through the exhibition case back

Troubleshooting

  • Watch has stopped:

    - If the watch has not been worn for a while, manually wind it by rotating the crown clockwise 30-40 times.

    - Ensure the watch is worn regularly (8-10 hours daily) for the automatic movement to maintain its power reserve.

  • Date not changing correctly:

    - Avoid setting the date between 9 PM and 3 AM. If you need to adjust the date during this period, first set the time outside this window, adjust the date, then reset the correct time.

  • Condensation under the crystal:

    - This may indicate a breach in water resistance. Immediately take the watch to a qualified watchmaker for inspection and repair to prevent further damage to the movement.

User Tips

  • Consistent Wear: For optimal performance of the automatic movement, wear your watch consistently. If you rotate watches, consider a watch winder to keep it running and accurate.
  • Bracelet Adjustment: The stainless steel bracelet can be adjusted by removing links. This is best done by a professional watchmaker to avoid scratching the bracelet or damaging the pins.
  • Time Zone Changes: When traveling across time zones, adjust the time by pulling the crown to the furthest position and rotating the hands. This is generally safer than using the quick-set date function if you are unsure of the watch's internal time cycle.

Warranty and Support

For any issues or inquiries regarding your BENYAR BY-5211 watch, please contact the seller or the official BENYAR customer support. Keep your purchase receipt as proof of purchase for any warranty claims. Specific warranty terms and conditions may vary by region and seller.

Related Documents - BY-5211

Preview Benyar Watch User Manual and International Guarantee
Explore the Benyar Watch User Manual, covering international guarantee details, premium materials like stainless steel and titanium, detailed function illustrations for time and date setting, mechanical watch operation, and essential care instructions.
Preview BENYAR Watch User Manual and International Guarantee Certificate
Comprehensive user manual and international guarantee details for BENYAR watches, covering operation, maintenance, materials, and technical specifications.
Preview BENYAR BY-5140 Watch Setting Guide
Comprehensive guide to setting the time, date, and using the stopwatch and tachymeter functions of the BENYAR BY-5140 chronograph watch.
Preview Rupert Neve Designs 5211 Two Channel Microphone Preamplifier with SILK - Operations Manual
Comprehensive operations manual for the Rupert Neve Designs 5211 Two Channel Microphone Preamplifier. Covers safety instructions, product overview, front and back panel controls, block diagram, specifications, frequency response, and warranty information.
Preview Cematic Wafer Butterfly Valve SS316 Teflon Seat - Model PMSS Technical Data Sheet
Comprehensive technical data sheet for the Cematic Wafer Butterfly Valve, model PMSS. Features SS316 stainless steel construction, Teflon seat, ISO 5211 mounting, and is suitable for various industrial applications including chemical processes, hydrocarbons, and HVAC. Includes detailed specifications, dimensions, parts list, and automation options.
Preview Z-C9AJBJ6Z-5211 Light Fixture Installation Guide and Safety Instructions
Comprehensive installation guide for the Z-C9AJBJ6Z-5211 light fixture. Includes essential safety warnings, parts list, tools required, step-by-step assembly instructions, and cleaning recommendations.