ALTHY H2-007

Contents

ALTHY H2-007 Performance Hydrogen Water Generator Bottle

User Manual

1. Product Overview

The ALTHY H2-007 is a portable hydrogen water generator bottle designed to produce hydrogen-rich water for health and beauty benefits. It features advanced SPE (Solid Polymer Electrolyte) and PEM (Proton Exchange Membrane) technology with a multilayer Platinum Plating Electrode and a USA DuPont NAFION-117 membrane, ensuring high purity hydrogen (99.99%) by separating oxygen, chlorine, and ozone. The device also includes a PPB and time display, a Type-C USB charging interface, and can be used with a hydrogen inhalation device.

ALTHY H2-007 Hydrogen Water Generator Bottle with packaging
Figure 1: ALTHY H2-007 Hydrogen Water Generator Bottle and Packaging

Product Structure

  • Cover: Top part of the bottle.
  • Body: The main water container, made of Korean LG imported PC (BPA-free food grade Tritan).
  • Base: Contains the electrolysis unit, display screen, and control buttons.
  • Switch: Power/mode button on the base.
  • Draining Vent: Located at the bottom for removing harmful substances.
  • Built-in Automatic Pressure Relief Valve: Ensures safe operation.
Exploded view of the H2-007 bottle showing components
Figure 2: Exploded View of H2-007 Components

2. Important Notices and Safety Guidelines

  • Use a 5V/2A power adapter for charging to avoid product damage or safety hazards.
  • Keep the product away from heat and fire.
  • Do not disassemble or repair the product yourself.
  • Do not wash or immerse the product directly in water to prevent mechanical failure. Wipe dry promptly if water accidentally spills on the body.
  • Do not lay the bottle flat or upside down during or after electrolysis.
  • Do not use carbonated beverages to generate hydrogen water, as internal pressure can become too high, posing an explosion risk.
  • Avoid using high-concentration mineral water, which can block the proton membrane channel and affect hydrogen production.
  • Do not use tea water, as it may generate tea scale minerals or other substances.
  • Applicable water types: Pure water, purified water, distilled water, RO water, pure water.
  • Applicable water temperature: 5°C-60°C.
  • Tighten the cover when making hydrogen to ensure optimal dissolution.
  • Hydrogen dissolved in water will gradually escape; it is recommended to drink within 30 minutes after generation. For high concentration, generate again if more than 30 minutes have passed.
  • Do not electrolyze without water in the bottle.
  • Before first use, remove the moisturizing plug from the base. Unscrew the bottle body and base, take out the plug, then reassemble.
  • Do not exceed the maximum water level when filling the bottle.

3. Setup and First Use

3.1 Initial Preparation

  1. Unpacking: Verify that all components are present: Hydrogen Water Bottle (1pc), Charging Cable (1pc), User Manual (1pc).
  2. Moisturizing Plug Removal: For first-time use, unscrew the bottle body from the base. Locate and remove the moisturizing plug from the base. Reassemble the bottle body and base securely.
  3. Initial Cleaning: Clean the bottle thoroughly.
  4. First Electrolysis Cycle: Pour purified water (below 60°C) into the cup, ensuring it does not exceed the maximum water level. Let it soak for 10 minutes. Perform electrolysis 1-2 times before regular use.

3.2 Charging the Device

Use the provided Type-C USB cable and a 5V/2A charger to charge the product. During charging, the battery symbol on the screen will show a filling animation. When fully charged, the battery symbol will be solid and no longer jump.

Working status display screen showing PPB, Battery, and Time indicators
Figure 3: Working Status Display Screen (Battery Indicator)

4. Operating Instructions

4.1 Power On and Mode Selection

  1. Start-up: Double-click the power/mode button. You will hear a “di” sound, and the screen will display the remaining power and working time.
  2. Choosing Working Time:
    • 5-minute Mode: When the screen displays “5min”, if no further action is taken within 2 seconds, the LED in the cup will light up, and the screen will show dynamic dot matrix flashes, indicating electrolysis is in progress.
    • 10-minute Mode: If the screen displays “5min”, tap the power/mode button again to switch to the 10-minute working mode.

4.2 Display Switching

During operation, tap the power/mode button to switch between the time display and the PPB (Parts Per Billion) display.

4.3 Completion and Shutdown

  1. Completion: At the end of the electrolysis cycle, the hydrogen water bottle will make a “di” sound and then automatically shut down.
  2. Manual Shutdown: To terminate operation or turn off the power supply during a cycle, press and hold the power/mode button for approximately 2 seconds. The device will power off automatically when the screen goes out.

4.4 Hydrogen Inhalation Device Usage

The H2-007 features a detachable design that allows the base to be used with a hydrogen inhalation device. Connect the inhalation device to the base unit as shown in the diagram. Refer to the official video tutorial for detailed instructions (QR code available in the original manual).

Hydrogen Inhalation Device and Water Bottle Adapter
Figure 4: Hydrogen Inhalation Device and Water Bottle Adapter

4.5 Water Bottle Adapter Usage

The device can be adapted to other water bottles using the provided water bottle adapter. This allows for greater flexibility in use. Refer to the official video tutorial for detailed instructions (QR code available in the original manual).

Detachable design for travel, gym, and inhalation
Figure 5: Detachable Design for Versatile Use

5. Maintenance

5.1 Regular Cleaning

  • Wipe the product's exterior with a wet soft cloth.
  • Remove any foreign matter from inside the water bottle and from the electrode.
  • For optimal performance, clean the device with citric acid every 2 to 4 weeks.

5.2 Long-Term Storage

If the product will not be used for an extended period, add a small amount of purified water into the bottle to keep the proton membrane moist. This helps maintain its activity.

5.3 Pressure Relief

After each electrolysis cycle, unscrew the bottle cover to relieve any built-up pressure inside the bottle. This prevents water leakage from the bottom of the bottle due to high pressure.

6. Troubleshooting

If you encounter any issues, please refer to the table below. If the problem persists, contact customer service.

AnomalyPossible CausesSolution
No bubbles or small amount of bubbles during electrolysisProton membrane is dry or not activated.Add purified water, soak for 10 minutes, and electrolyze several times to activate the membrane.
Amount of bubbles reduces during operationNormal phenomenon as inner pressure increases during electrolysis.This is normal operation. No action required.
Water seepage at the bottom of the cupCup cover not unscrewed after electrolysis (pressure build-up), sealing ring misalignment, improper installation, or loose components.Always unscrew the cover after electrolysis to relieve pressure. Check sealing rings for correct placement and ensure all components are tightened.
Low batteryBattery charge is low.Charge the product using a 5V/2A Type-C charger.
Product completely powerless (lightning icon displayed)Battery is completely depleted.Charge the product immediately.

6.1 Frequently Asked Questions (FAQ)

  • Why is there water in the cup I received?
    The ion membrane needs to be kept moist to maintain its activity. Purified water is added to the electrolytic cell during production and covered for storage. This is normal and does not indicate a used product.
  • Can I use the hydrogen-rich water bottle to electrolyze other beverages?
    No. The bottle is designed only for water. Other beverages contain impurities that can block and damage the electrolyzer.
  • Does the hydrogen-rich water cup change the ORP value and pH value of water?
    The primary function is to generate hydrogen-rich water and reduce the ORP (Oxidation-Reduction Potential) value (e.g., from +100mV to -200mV). It does not necessarily change the pH value of the water.

7. Specifications

FeatureSpecification
Model NumberH2-007
Brand NameALTHY
TypeIonizer, Water Pitcher
UsePitcher, Direct Drink, Terminal Purification
InstallationDesktop
Water Quality RequirementsHigh Quality Drinking Water (Mineral, Purified, Distilled, RO, Pure Water)
5 Stage FiltrationNo
Water Yield (Liter/Minute)2.0
Capacity280ml
Product SizeΦ60 × 230mm
Power SourceRechargeable battery
Power4W, Type-C USB 5V/1A or 5V/2A
Battery Capacity1800mAh
Working Times (5 Min. cycle, full charge)Approx. 15 times
Working Times (10 Min. cycle, full charge)Approx. 8 times
MaterialTitanium (electrode), USA Food grade Tritan (cup body)
Electrolysis TechnologyDuPont SPE+PEM Dual Chamber Ionizer, Multilayer Platinum Plating Electrode
Hydrogen Purity99.99%
Max PPBUp to 5000ppb
ORPUp to -300mV ~ -700mV
CertificationRoHS, IHSA (International Hydrogen Standard Association) Certified
Diagram illustrating H2 generation performance
Figure 6: H2 Generation Performance Metrics
Bar chart comparing H2-007 PPB with other models
Figure 7: PPB Comparison with Other Models

8. User Tips

  • For best results, drink hydrogen water within 30 minutes after it is generated.
  • Regularly clean the device with citric acid (every 2-4 weeks) to maintain optimal performance and longevity.
  • Ensure all sealing rings are correctly aligned and components are tightened to prevent any leaks.
  • It is normal for the PPB reading to fluctuate or decrease slightly after initial use, and for the ORP value to be around -450mV to -600mV.
  • The ozone and chlorine separation feature contributes to a cleaner taste compared to cheaper models.
  • Never operate the electrolysis function without water in the bottle.
  • Avoid using carbonated beverages or high-concentration mineral water to prevent damage and ensure safety.

9. Warranty and Support

The ALTHY H2-007 is certified by the International Hydrogen Standard Association (IHSA), ensuring adherence to high quality and performance standards. A detailed laboratory report can be accessed by scanning the QR code provided in the original product documentation.

IHSA Certification and H2 Analytics Laboratory Report
Figure 8: IHSA Certification

Customer Service

If you encounter any issues that cannot be resolved using the troubleshooting guide, or if you have further questions, please contact ALTHY customer service. To assist us in providing the best support, please provide a detailed description of the problem, including any relevant videos or photos.

Customer Service Email: althyserve@aliyun.com

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.