1. Introduction
The SUSWE 750W VFD (Variable Frequency Drive) Frequency Converter is a compact and efficient device designed for precise motor speed regulation. It converts single-phase 220V AC input into three-phase 220V AC output, making it suitable for various industrial and commercial applications. This manual provides essential information for the safe and effective installation, operation, and maintenance of your VFD.
Key applications include motor fan speed regulation, constant pressure water supply systems using water pumps, and general speed control for conveyer belts, packaging machines, food processing equipment, and other transmission systems. Its design focuses on energy saving and power efficiency.

2. Specifications
| Feature | Specification |
|---|---|
| Model Number | suswe-750 |
| Type | DC/AC Inverter (Frequency Converter) |
| Input Voltage | Single Phase 200V~240V AC |
| Output Voltage | 3 Phase 200V~240V AC |
| Input Frequency | 50/60Hz |
| Output Frequency Range | 0-99Hz |
| Output Power | 750W (0.75kW) |
| Output Type | SINGLE |
| Dimensions (L*W*H) | 13 cm * 6 cm * 10.2 cm (approx. 10.2*6*13) |
| Weight | 0.5 kg |
| Certification | CE, FCC, RoHS |
| Special Features | Built-in intelligent logic controller, electronic thermal relay function, IPM module for protection, V/F curve function, RS485 communication |
Dimensions


The recommended opening size for installation is 52.5mm * 80mm * 130mm.
3. Product Overview: Control Panel
The VFD features a user-friendly control panel for easy operation and parameter setting.

- Display Area: Shows frequency, current, and other operational data.
- MODE Key: Used for function selection and viewing various parameters such as set frequency (Fxxx), operating frequency (Hxxx), operating current (Axxx), motor direction (FWD/REV), input voltage (Uxxx), inverter temperature (Txxx), input point status (Lxxx), PID parameter display (X.X - X.X), and feedback value.
- ▲ (Up) Key: Adds function when setting data or increases frequency when frequency is controlled by the panel.
- ▼ (Down) Key: Subtracts data when setting data or reduces frequency when frequency is controlled by the panel.
- ENTER Key: Press to enter parameter mode when setting Pxxx parameters, and press again to save the set parameters after modification.
- JOG Key: Initiates jog operation function.
- RUN Key: Starts inverter panel operation.
- STOP / RESET Key: Stops operation mode and clears any fault alarm function in the fault display.
- Potentiometer (Regulating frequency): A knob for adjusting the frequency.
4. Installation and Wiring
Proper installation and wiring are crucial for the safe and correct operation of the VFD. Refer to the wiring diagram carefully.


Wiring Instructions:
- Power Input (L, N): Connect the single-phase 220V AC power supply to the 'L' and 'N' terminals.
- Motor Output (U, V, W): Connect the three-phase motor to the 'U', 'V', and 'W' terminals.
- Grounding (PE): Ensure the VFD is properly grounded by connecting the 'PE' terminal to an earth ground. This is critical for safety.
- Relay Output (CM, NC, ON): These terminals provide a relay output for control purposes. CM is common, NC is normally closed, and ON is normally open.
- Digital Inputs (X0, X1, X2, X3): These are digital input terminals for external control signals.
- 12V/P: Power supply for external components.
- Analog Input (AI, A+): Supports 0-5V/0-10V analog input. An external 250Ω resistor is required for 4-20mA matching.
- 485 Communication (A, B): For RS485 communication, connect to 'A' and 'B' terminals.
- Y0 Point: This is a multi-function composite output point. It can be either a brake resistor or a general transistor output. Only one can be used.
Always ensure power is disconnected before performing any wiring to prevent electric shock.
5. Operation
The VFD is designed for user-friendly operation. Follow these steps for basic control:
Basic Operation Sequence:
- Power On: Ensure all wiring is correct and secure before applying power.
- Set Frequency: Use the potentiometer on the control panel to adjust the desired output frequency. Alternatively, use the ▲/▼ keys if the frequency is controlled via the panel.
- Start Motor: Press the RUN key to start the motor. The display will show the operating frequency.
- Stop Motor: Press the STOP / RESET key to stop the motor.
- Jog Operation: For momentary operation, press the JOG key.
Viewing Real-time Parameters:
During operation, you can use the MODE key to cycle through various real-time parameters such as operating frequency, current, motor direction, input voltage, and inverter temperature. Use the Shift key to view these parameters.
6. Parameter Settings
The VFD allows for detailed parameter configuration to optimize performance for specific applications.

Entering and Modifying Parameters:
When the panel displays a parameter code (e.g., Pxxx), you can adjust its value:
- Use the ▲ (Up) and ▼ (Down) arrow buttons to navigate to the desired parameter number.
- Press the ENTER key to enter the data modification mode for that parameter.
- Adjust the parameter value using the ▲ (Up) and ▼ (Down) keys.
- After modification, press the ENTER key again to save the new value.
- If the panel does not display Pxxx mode, press the MODE key until Pxxx is displayed.
Advanced Settings:
- V/F Curve Function: The VFD allows you to set custom V/F curves to meet specific application requirements. Refer to the detailed parameter list in the full manual for specific V/F curve parameters.
- Panel Lock: To unlock the panel when in lock mode, press the ENTER + key. Ensure the panel lock function is enabled first.
7. Troubleshooting
This section provides a list of common fault codes and their corresponding descriptions and suggested actions.

| Alarm Type | Fault Description | Fault Comment |
|---|---|---|
| OC | Instantaneous overcurrent | Check whether the motor is normal |
| OCA | Acceleration overcurrent | Check whether the motor is normal |
| OCD | Deceleration overcurrent | Adjust the acceleration time appropriately |
| OCN | Constant speed overcurrent | Adjust the deceleration time appropriately |
| OU | Overpressure | Check whether the machine is normal and the voltage is stable |
| LU | Undervoltage | Adjust the acceleration and deceleration time properly, and check whether the mains supply is normal |
| OH | Inverter overheating | Detect whether the mains supply is normal (180V-240V) |
| EF | External fault | Detect external sensors. Whether the input is normal |
| ERS | Failure restart failed | Restart the drive |
| LP | Input phase failure | Check whether the mains supply is normal |
| OL1 | Motor overload | Check whether the motor is normal and whether the load is too heavy |
| OL2 | Inverter overload | Check whether the motor is normal and whether it matches the frequency converter power |
| OL3 | Temporary motor overload | Check whether the motor is normal and whether it matches the frequency converter power |
| OL4 | Temporary overload of frequency converter | Check whether the load matches the motor |
| 485 | Communication failure | Check whether the communication line is normal, and whether the upper computer communication is normal |
| PID | PID failure | Check whether analog input is output and whether sensor is normal |
| NO | No fault alarm | Check whether analog input is output and whether sensor is normal |
If a fault persists after following the suggested actions, please contact customer support.
8. Maintenance
Regular maintenance helps ensure the longevity and optimal performance of your VFD.
- Cleaning: Periodically clean the exterior of the VFD to prevent dust accumulation, especially around ventilation openings. Use a soft, dry cloth. Do not use liquid cleaners.
- Ventilation: Ensure adequate airflow around the VFD. Blocked vents can lead to overheating and potential damage.
- Connections: Regularly check all wiring connections for tightness and signs of corrosion. Loose connections can cause intermittent operation or damage.
- Environmental Conditions: Operate the VFD within its specified environmental conditions (temperature, humidity) to prevent premature failure.
9. User Tips
- Grounding is Key: Always ensure the VFD is properly grounded. This is a critical safety measure and helps prevent electrical noise.
- Motor Compatibility: Verify that your motor's specifications (voltage, current, power) are compatible with the VFD's output capabilities.
- Start Low: When first operating, start with lower frequency settings and gradually increase to observe motor behavior.
- Consult Diagrams: Always refer to the detailed wiring diagrams before making any connections. If unsure, seek professional assistance.
- Parameter Backup: For complex setups, note down your parameter settings. This can save time if a reset is ever needed.
10. Warranty and Support
The SUSWE 750W VFD Frequency Converter comes with a 1-year warranty from the date of purchase, covering manufacturing defects and malfunctions under normal operating conditions.
For technical assistance, debugging guidance, or warranty claims, please contact your seller or SUSWE customer support. We offer 24-hour one-to-one debugging guidance and remote package debugging services to ensure you get the most out of your product.
Please retain your proof of purchase for warranty validation.