jikong JK-B2A24S20P-HC

Contents

JKBMS B2A24S20P-HC V19 Smart Battery Management System User Manual

Model: JK-B2A24S20P-HC | Brand: JIKONG

1. Introduction

The JKBMS B2A24S20P-HC V19 is an intelligent Battery Management System (BMS) designed for large-capacity series lithium battery packs. It provides comprehensive management and protection features, including voltage acquisition, high-current active balancing, overcharge, over-discharge, overcurrent, and over-temperature protection. The system also integrates a coulomb meter, Bluetooth communication, GPS remote functionality, and heating capabilities. It is compatible with various lithium battery types such as LiFePO4, Li-Ion, and LTO, supporting 8S to 24S configurations.

The BMS utilizes energy transfer active balancing technology with a continuous balancing current of 1A/2A, ensuring battery consistency, extending range, and delaying aging. It is managed via a mobile APP available for both Android and iOS, allowing real-time monitoring and parameter adjustments.

Video: JIKONG Active Balance BMS overview, demonstrating active balancing, smart management via app, and compatibility with various battery string numbers.

2. Setup

2.1. Unpacking and Inspection

Upon receiving your JKBMS, carefully unpack the package. Handle the protection board gently and avoid turning it upside down. Before opening, inspect the packaging for any signs of impact or damage. Ensure all components listed in the packing list are present:

  • BMS Unit
  • Operating Manual
  • NTC Temperature Sensor (40cm)
  • Switch (50cm)
  • Wiring Harness (70cm)
  • Pack Box
JKBMS Packing List

Image: JKBMS Packing List, showing the BMS unit, manual, NTC sensor, switch, and wires.

2.2. Hardware Connection

The JKBMS B2A24S20P-HC series protection board is suitable for 7-24 series lithium battery packs. The specific wiring method depends on the number of cells in your battery pack. Always ensure the balance cables are properly connected and the P- and B- terminals are correctly wired before powering on.

JIKONG BMS Wire Diagram

Image: JIKONG BMS Wire Diagram, illustrating connections for 8S-24S battery configurations.

JKBMS Connection Scheme

Image: JKBMS Connection Scheme, detailing ports for Temperature sensor, CAN/RS485, GPS, Display, and Heat Function.

Important Wiring Notes:

  • Connect the protection board and battery pack according to the provided wiring diagram.
  • Ensure the last power cord is connected to the main positive pole.
  • The total voltage of the battery pack must be greater than 20V (for default BMS) or 10V (for 4S BMS) before startup.
  • The heating wires for JK-B2A20S20P-HC and JK-B2A24S20P-HC are available in yellow and black versions and will be sent randomly.
Heating Wires

Image: Heating wires for JKBMS, available in yellow and black.

2.3. Interface Definition

The JKBMS features several interfaces for communication, display, and sensors. Below is a table detailing the pin definitions for the main connectors (P1, P2, P3, P4, P5, P6, P7) and the LED indicator (D1).

JK-BxAxxS-15P/20P Connector Pin Definitions
ConnectorPin NumberNameDefinition
P1 (XH-15AW) - Balancing & Acquisition Interface1B-Total negative battery
2B1The first battery positive
.........
15B14The fourteenth battery positive
P2 (XH-11AW) - Balancing & Acquisition Interface (continued)1B15The fifteenth battery positive
.........
7B21The twenty-first battery positive
8B22The twenty-second battery positive
9B23The twenty-third battery positive
10B24The twenty-fourth battery positive (Total battery positive)
11B+Protection board power supply, connected to the battery
P3 (XH-4AW) - Temperature Interface1T1AFirst temperature sensor pin A
2T1BFirst temperature sensor pin B
3T2ASecond temperature sensor pin A
4T2BSecond temperature sensor pin B
P4 (A1254WF-3A) - Communication Interface1DNCAN_L/RS485-B signal negative
2DPCAN_H/RS485-A signal positive
3GNDSignal ground
P5 (1.25T-4PWT) - GPS Interface1VGPSPower output, voltage close to B+
2TXUART TX, 3.3V
3RXUART RX, 3.3V
4GNDPower/signal ground
P6 (A1254WF-6A) - Display Interface1VCCDisplay power output
2ADisplay RS485 signal positive
3BDisplay RS485 signal negative
4GNDNegative terminal
P7 (A1254WT-7A) - Heating Interface1-4HT-Heater element negative electrode
5K+Activate the positive signal
6CD+Charge indication input positive terminal
7CD-Charge indication input negative terminal
P-Connect to external load or negative terminal of charger
B-Connect to the negative battery terminal
D1Bluetooth connection indicator: Steady on when connected, blinking when disconnected.

2.4. APP Installation

The JKBMS is managed via a mobile application. To install the app:

  1. Scan the QR code below with your mobile device.
  2. For iOS devices, search for "JIKONG BMS" in the APP STORE.
  3. For Android devices, search for "JK BMS" in the Google STORE. Android Version 7 or higher is required.
Mobile APP Link QR Code

Image: QR code for JIKONG BMS Mobile APP download.

2.5. Device Activation

Before activating the BMS, double-check all wiring connections, especially the balance cables and the P-/B- terminals. Ensure the protection board is securely fixed to the battery pack. Incorrect connections can lead to abnormal operation or damage.

The BMS does not have a power-on control switch. It is designed for charging activation mode. After battery assembly, connect the charger (charger voltage 2V higher than battery voltage) to activate the BMS. Alternatively, if you have a display screen and button, you can activate the BMS by inserting the cable into the display interface and pressing the button.

3. Operating

3.1. Active Equalization

The JKBMS employs active equalization to balance cell voltages. It transfers energy from higher-voltage cells to lower-voltage cells. Before using this function, set the basic battery parameters in the APP, including the number of cells, battery capacity, trigger equalization differential pressure (default is usually fine), voltage calibration, and current calibration. The default balance current is 1A/2A, adjustable based on battery capacity (recommended not to exceed 0.2C of battery capacity). The balancing function automatically activates when the voltage difference between any two strings exceeds the set value and turns off when it falls below the set value. This function can be disabled via the BMS control page in the APP if not needed.

3.2. Heating Function

The optional heating function uses a resistance heater or heating film to warm the battery at low temperatures, preventing reduced battery activity during charging and discharging. The designed heating current is 4A. Users can switch this function on/off via the APP based on ambient temperature. It is recommended to install a temperature control switch (e.g., 45°C to 65°C normally closed) in series with the heating circuit as a secondary protection against thermal runaway.

3.3. Smart Energy Working Modes

The JKBMS supports various smart energy working modes to optimize battery life and performance:

  • Storage Mode: Used during transportation, offline, or wireless transmission off mode. The BMS is in a low-power state and does not consume battery pack current.
  • Normal Working Mode: Activated when the charger is inserted in storage mode or off mode. All protection, equalization, and communication functions return to normal operation.
  • Shutdown: To prevent power waste and battery damage during long periods of inactivity, the BMS has an automatic shutdown voltage. It automatically shuts down if a cell falls below this voltage.
  • Standby Mode: When the battery pack is in a static state (no charge/discharge current, no equilibrium current), the BMS automatically enters standby mode after a set time (1-30 days, configurable).
Smart Energy Working Mode Switching

Image: Diagram illustrating the smart energy working mode switching logic.

3.4. Mobile APP Operation

The JKBMS APP provides a user-friendly interface for monitoring and controlling your battery system. After installing the app:

  1. Ensure Bluetooth is enabled on your mobile phone.
  2. Open the JKBMS APP.
  3. Click the scan button (usually in the top left corner) to search for devices.
  4. Select your device from the list. The default connection password is 1234.
  5. For the first startup, you will need to set parameters. The default parameter setting password is 123456. Simply set the number of units (battery strings) and battery type.
  6. After setting parameters, return to the real-time status page to check the battery status. The app will display cell voltages, with the highest voltage shown in blue and the lowest in red. Ensure no error messages are prompted for normal operation.
Mobile APP Page Display

Image: Screenshots of the JKBMS Mobile APP interface, showing real-time monitoring and various settings.

Intelligent JKBMS APP

Image: Intelligent JKBMS APP interface, highlighting ease of monitoring battery status.

4. Maintenance

Regular maintenance of your JKBMS ensures optimal performance and longevity of your battery pack.

  • Regular Monitoring: Use the mobile APP to regularly check battery cell voltages, temperatures, and overall status. This helps identify potential issues early.
  • Parameter Review: Periodically review the BMS parameters in the APP to ensure they are still appropriate for your battery type and usage.
  • Cleanliness: Keep the BMS unit clean and free from dust and debris. Ensure proper ventilation if installed in an enclosure.
  • Connection Check: Occasionally inspect all wiring connections for tightness and corrosion.
  • Software Updates: Check the JIKONG BMS website or APP for any available firmware updates to ensure you have the latest features and bug fixes.

5. Troubleshooting

The JKBMS is equipped with multiple protection features to safeguard your battery. Understanding these protections and how they recover is key to troubleshooting.

5.1. Six Security Protection Features

The BMS provides six major protection mechanisms:

  • Overcharge Protection: Prevents over-charging, which can affect battery life.
  • Short Circuit Protection: Automatic protection when a short circuit occurs.
  • Over-discharge Protection: Prevents the battery from running out completely.
  • Overcurrent Protection: Prevents the current from exceeding the battery's safe range.
  • Balance Protection: Ensures cell voltage consistency.
  • Over-temperature Protection: Prevents the battery from overheating.
Six Security Protection

Image: Diagram illustrating the six security protection features of the JKBMS.

5.2. Protection and Recovery Mechanisms

  • Charge Overvoltage Protection & Recovery: The BMS will shut down charging if any cell's voltage exceeds the set overvoltage protection voltage. Charging resumes when all cell voltages drop below the recovery voltage.
  • Discharge Undervoltage Protection & Recovery: If any cell's voltage drops below the set undervoltage protection voltage during discharge, the BMS will cut off discharge. Discharge resumes when all cell voltages rise above the recovery voltage. An automatic shutdown voltage is also set, below which the BMS will shut down completely.
  • Charge Overcurrent Protection & Recovery: If the charging current exceeds the set continuous charging current for a specified delay, charging will be stopped. It resumes after a set recovery time.
  • Discharge Overcurrent Protection & Recovery: Similar to charge overcurrent, if discharge current exceeds the set limit for a delay, discharge is cut off. It resumes after a set recovery time. (Note: Max continuous discharge current cannot exceed 150A/200A).
  • Over Temperature Protection & Recovery: If the BMS detects temperatures above the set limits for charging or discharging, it will stop the respective operation. Operation resumes when temperatures fall below the recovery thresholds.
  • Low Temperature Protection & Recovery: If the BMS detects temperatures below the set limits for charging, it will stop charging. Charging resumes when temperatures rise above the recovery thresholds. Using the heating function in cold environments is recommended.
  • Short Circuit Protection & Recovery: The BMS has built-in short circuit protection. Users can adjust the short circuit protection delay and recovery time via the APP. If a short circuit occurs during charging or discharging, the BMS will cut off power and resume after the recovery time.

5.3. Discharge Precharge Function

The BMS includes a discharge precharge function with a default time of 5 seconds. This can be enabled or disabled via the APP. Setting the precharge time to 0 disables the function.

5.4. Emergency Switch

In case of issues like over-temperature, over-discharge, over-charge, or string drop during normal use, activating the emergency switch in the BMS control page of the APP will enable charge and discharge for 30 minutes. This provides an emergency operational period, even if a single cell reaches automatic shutdown voltage, to prevent critical situations like being stranded.

5.5. Intelligent Sleep

The intelligent sleep function allows the BMS to enter a low-power state when in standby (charging and discharging current less than 1A for 26 consecutive hours), reducing energy consumption. The BMS can be reactivated by pressing a button (if available) or by connecting a charger.

5.6. Communication Function

The BMS supports optional CAN/RS485 communication. Users can select CAN or RS485 for multiplexed ports on the APP's BMS control page. Address and communication protocols can be configured based on specific requirements. Refer to the Jikong Protection Board communication protocol document for details.

6. Specifications

The JKBMS B2A24S20P-HC V19 is a robust and versatile BMS. Key specifications are detailed below:

General Specifications
FeatureValueUnit
Supply Voltage20-100V
Operating Power Consumption<800mW
Operating Temperature-30 to 70°C
Max. Collection Strings24Strings
Max. Balancing Current2A
Max. Charging Current200A
Max. Discharge Current200A
Max. Instantaneous Current350A
Max. Internal Loop Resistance0.5mΩ
Size (L*W*H)162*102*20.4mm
Finished Weight430g
JKBMS Dimensions

Image: Dimensions of the JKBMS unit (162mm x 102mm x 20.4mm).

Default Parameters (Example for LiFePO4):

Default Parameters for LiFePO4 Battery Type
ParameterValueUnit
Balancing Initial Voltage3V
Max. Balancing Current2A
Unit Overcharge Voltage3.6V
Single Overcharge Protection Recovery3.55V
Monomer Undervoltage Protection2.6V
Single Undervoltage Protection Recovery2.65V
Automatic Shutdown Voltage2.5V
SOC-0% Voltage2.6V
SOC-100% Voltage3.5V
Trigger Balancing Differential Pressure0.01V
Charging Overcurrent Protection Delay30S
Charging Overcurrent Protection Release Time60S
Discharge Overcurrent Protection Delay300S
Discharge Overcurrent Protection Release Time60S
Short-circuit Protection Delay1500µS
Short-circuit Protection Release Time60S
Charging Overtemperature Protection70°C
Charging Overtemperature Recovery60°C
Discharge Overtemperature Protection70°C
Discharge Overtemperature Recovery60°C
Charging Low Temperature Protection-20°C
Charging Low Temperature Recovery-10°C
MOS Overtemperature Protection100°C
MOS Overtemperature Recovery80°C

The JKBMS is designed to operate reliably in a wide range of temperatures, from -30°C to 90°C, ensuring normal discharge even in extreme conditions.

Cold and High Temperature Resistant

Image: JKBMS operating temperature range from -30°C to 90°C.

7. Warranty and Support

The JKBMS B2A24S20P-HC V19 is certified with CE, FCC, and RoHS, ensuring compliance with international quality and safety standards.

For detailed technical support, advanced parameter settings, or specific communication protocols, please refer to the comprehensive PDF user manual available at: JKBMS User Manual (PDF). Additional resources and protocols can be found at: JIKBMS Instructions and BMS Protocol.

8. User Tips

  • Verify Wiring: Always double-check all wiring connections, especially the balance cables, before initial power-up to prevent damage.
  • Initial Activation: Ensure your battery pack's total voltage meets the minimum requirement (20V for default BMS) before attempting to activate the BMS.
  • App Password: Remember the default APP connection password is '1234' and the parameter setting password is '123456'.
  • Regular Monitoring: Utilize the mobile APP to frequently monitor your battery's health and cell balance for optimal performance and longevity.
  • PDF Manual: For any complex configurations or detailed technical information, consult the full PDF user manual.
Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.